1. Open up the CADWorx Catalog and Specification Editor. Click the File
dropdown and click New Catalog as shown in Figure 1.
2. As shown in Figure 2, the New Catalog dialog window has six
categories that need to be filled out.
Name: Specify a name for the Catalog.
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 1/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Figure 1 – CADWorx
Once everything has been selected in Figure 2, press OK.
Submit Support Ticket
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 2/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
4. Once the New Catalog has been created, click the Catalog Data button located on the Ribbon
below in Figure 3. This will open the Transfer Catalog Data dialog window and an automatic
prompt will pop up asking “Would you like to use the current catalog for target?”. Select Yes.
5. As shown in Figure 4 below, There will be two Directory Boxes at the top of the window: Target
and Source.
Target will be filled out automatically because of the “yes” selection at the autoprompt.
Source is empty so it need’s to be specified and the out-of-the-box CADWorx catalog will be
used here. (See Source Directory in the image below for CADWorx Catalog location.)
Once the Source Catalog has been specified, both the Source and Target windows will be filled
with the Table Folders. Since the Target Catalog is brand new, there will be nothing in any of the
table folders. Expand the Table Folders that are required and select the tables that will be used. In
this situation, expand the Size, Material, Schedule, and Thickness Folders and choose each table
inside. Once selected, drag them over to the Target Catalog (anywhere in the Target window box),
save the Target Catalog, and press close. (See Figure 4)
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 3/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Submit Support Ticket
6. Now click the Import by Spec button on the Ribbon. This will bring the Import CADWorx Legacy
Catalog from Spec File dialog window up. (See Figure 5)
7. There will be four Source locations that can be specified as shown in Figure 6:
Specification File: This will be the legacy specification file that is to be used for the new
catalog that is being created.
Library Folder: This is the folder where the legacy library folders are located that are to be
used for the new catalog that is being created.
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 4/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Topworks Folder: If there is any Topworks being imported then this is the location they will
be imported from. The default is the 2014 CADWorx Spec folder and does not need to
change if there aren’t any that need to be imported.
DataBaseCodes File: If there are any Database Codes being imported then this is the
location they will be imported from but can be left blank if there aren’t any to be used.
Once all Sources have been selected, check the Select / deselect all button in the bottom right to
select all the data files and then press the import button. If more specification files are needed,
browse one by one, select all the date files required and click the import button. (See Figure 6)
Submit Support Ticket
8. Once all of the specification files that are required have been imported, press close. Save the
Catalog that has been created and that will be the last step in creating a new catalog.
GO TOP OF PAGE
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 5/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
1. Open up the CADWorx Catalog and Specification Editor. Click the File
dropdown and click New Project as shown in Figure 7.
2. In the New Project dialog window shown in Figure 8, there will be six
categories that will need to be filled out.
3. The five buttons below BOM type can be left alone at this time. 2015 Catalog and
Layer Manager
Part Number Format…
Tag Format…
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 6/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Submit Support Ticket
GO TOP OF PAGE
CADWorx 2015: Importing the Legacy Specification to the New Project File
1. Once the new Project File has been created, click the Import Legacy Specification button located
on the Ribbon. (See Figure 9 below)
2. In the Import Legacy Specifications dialog window, there will be two directory paths to select:
Specification and Catalog.
Specification will be the legacy specification that is being imported.
Catalog is greyed out because the Catalog was specified earlier.
3. Once the specification is selected, press Import and it will convert the data to the project. If more
than one specification is needed in the Project, press Close and repeat process by clicking the
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 7/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Import Legacy Specification button and choosing the next specification. (See Figure 10)
Figure 10
Submit Support Ticket
Figure 11 –
CADWorx Catalog
EndType Data
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 8/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Since each EndType Table was created based on the different Data Tables, they will need to be
consolidated into a single EndType table for each class. In this case, the 150lb class Flanged end types
will be consolidated into one table. Rather than creating a new EndType Table and adding every size,
choose the table that has the largest range of sizes in use and rename it to a basic name (FLG_150 in
this case). Then, add the missing sizes required by right-clicking on the MAINSIZE column and
choosing “Add MAINSIZE…” (See Figure 12 below).
Once the sizes are added, fill in the empty columns for the new sizes by either manually entering them
or copying them from a different EndType Table. Now that the EndType Tables have been consolidated,
the corresponding Data Tables need to match. Expand the Data Tables in the Catalog Data window and
open up the the data tables that match the newly created EndType Tables. In this situation, the Valve
Data Tables all tie together with the EndType Tables (See Figure 13 below).
Figure 13 –
Catalog EndType
Datatables
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 9/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Once each Data Table is opened, select the Start dropdown in the Default EndType Data Table Setup
and choose the correct EndType Table (See Figure 14 below). After all of the corresponding Data
Tables have been updated to the combined EndType Table, remove the unused EndType Tables by right
clicking on each and selecting Remove.
Submit Support Ticket
Figure 14-
CADWorx
Catalog Default
EndType Data
Selection
Once all of the specifications have been imported, EndType Tables combined, and Data Tables updated
to the correct EndType Table, the Catalog and Project can be saved and that concludes the Spec
Conversion for both Catalog and Project.
SHARE
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 10/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Leave a Reply
You must be logged in to post a comment.
Email:
Password:
Submit Support Ticket
Remember Me
LOG IN
Register
UPCOMING EVENTS
N OV
all-day Visit DotProduct at
15 Autodesk Uni...
Tue (http://www.ecedesign.com/event/vi
(http:// sit-dotproduct-at-autodesk-
www.ec
university-november-15-17/?
edesig
n.com/c instance_id=4017)
adworx
- all-day PV Elite Training
analysi November 15-16... @ ECE Training
s-
event-
Center
calend (http://www.ecedesign.com/event/p
ar/actio v-elite-training-11-15-2016-11-16-
n~oned
2016/?instance_id=3664)
ay/exa
ct_date
~11-15-
2016/)
JAN
all-dayCADWorx Plant
17 Professional Train... @ ECE
Tue Training Center
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 11/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
(http:// (http://www.ecedesign.com/event/c
www.ec
adworx-plant-professional-1-17-
edesig
n.com/c 2017-1-19-2017/?instance_id=4058)
adworx
-
analysi
s-
event-
calend
ar/actio
n~oned
ay/exa
ct_date
~1-17-
2017/)
F EB
all-day CADWorx Structural
21 Modeling Trai... @ ECE Training
Tue Center
Submit Support Ticket
(http:// (http://www.ecedesign.com/event/s
www.ec
tructural-modeling-2-21-2017-2-22-
edesig
n.com/c 2017/?instance_id=4075)
adworx
-
analysi
s-
event-
calend
ar/actio
n~oned
ay/exa
ct_date
~2-21-
2017/)
View Cart ( 0 )
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 12/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
SEARCH
LATEST RELEASES
BricsCAD V16
CADWorx Plant Professional 2016 SP2 HF2
CADWorx P&ID Professional 2016 SP2
Submit Support Ticket
ANNOWorx: 4.1.291.1832
BUBBLEWorx: 4.1.291.1832
ISOWorx: 4.1.291.1832
LINKWorx: 4.1.291.1832
SHEETWorx: 4.1.291.1832
MTOWorx: 4.1.291.1832
STRESSWorx: 4.1.291.1832
SUPPORTWorx: 4.1.291.1832
VIEWWorx: 4.1.291.1832
SPECWorx: 5.5.3
DBWorx: 2.0.2
ELECTROWorx: 2016
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 13/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
RECENT POSTS
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 14/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
CATEGORIES
BricsCAD (4)
TAGS
Product Announcement
SPECWorx Training Videos Webinar
Announcement Webinar
Recap
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 15/16
28/10/2016 CADWorx Plant Professional 2015: Importing Legacy Specifications
Go to top
ECE Design for all your Intergraph CADWorx & Analysis Solutions. When People Talk, Great Things Happen!
Contact Sales | Contact Support
713-623-1502 | 312-235-6960
Submit Support Ticket
http://www.ecedesign.com/2014/10/17/cadworx-plant-professional-import-legacy-specifications/ 16/16