You are on page 1of 2

AL-RF70-210 galley solutions

worldwide

Refrigerator Freezer

Aerolux Limited Aircraft Galley Equipment Manufacturers


Chorley Road, Blackpool, Lancashire FY3 7XQ, England
Tel +44 (0)1253 396670 Fax +44 (0)1253 300074
Email info@aerolux.co.uk • sales@aerolux.co.uk
www.aerolux.co.uk
AL-RF70-210
• Refrigerator / Freezer is a self-contained unit designed for the
storage of chilled or pre-frozen food and beverages onboard
commercial, commuter and corporate aircraft.
• Cooling air for the condenser is drawn in and exhausted by the
front grills at the top of the unit eliminating the need for special
ducting.
• The unit outer body is made from a lightweight aluminium alloy;
the inner liner is of polished stainless steel for strength and ease of
cleaning.
• The unit incorporates removable aluminium baskets.
• Either left or right hand opening door.
• The door décor trim can be provided to the customer’s choice.
• Internal capacity is 0.17 cu.m (6.25 cu. ft).
Characteristics Operational Range
Power Supply 115 VAC 400 Hz 3 Phase Ambient Temperature 15-35°C (59-
Nominal AC Current 2.5 Amps 95°F)
Recommended Circuit Breaker 5 Amps Altitude 0 to 8000ft

Height 883mm (34.75”)


Performance
Width 584mm (23”)
Temperature Settings 4-8°C (39.2-
46.4°F) Chill, -10°C (14°F) Freeze Depth 686mm (27”)
Empty weight 73kg (160.9lbs)
Controls
POWER ON/OFF switch, when selected Interface details
illuminates green. If the unit encounters
Electrical Connector MS24266R14B12P
a fault, the POWER ON/OFF switch will
Mounting Attachment 10-32 UNF bolts
illuminate red to show “FAIL”.
x 5 per side, x 5 front right, ø6.3 mm x
CHILL/FREEZE switch illuminates white
5 front side
when CHILL mode is selected and
illuminates blue when FREEZE mode is Documentation:
ON. ATA / iSpec 2200 CMM
LCD displays the temperature of the Release:
unit storage compartment when the EASA Form 1 or Certifi cate of
power switch is selected ON. Conformity (COC)* model dependant
FILTER legend illuminates amber when
*EASA Form 1 can be provided by a DOA to POA
the air fi lter needs servicing. Arrangement depending on commercial contract.
Cost applicable.

Outline drawing Electrical interface

PIN OUT
A phase 4
B phase 7
C phase 10
UNUSED 2
UNUSED 3
Ground 5
Ground 6

Caution: Do not use the information contained in this document to


perform installation design as this data is subject to change.
Copyright © 2015 Aerolux Limited