You are on page 1of 1
LL. Data of the Example The design data shall be as follows: Live load : 4.0 kNinr attypieal floor 21S Kin’ on terrace Floor finish 2 LOkN im? Water proofing 22.0 Nin? Tenrace finish 10KNin? Location : Vadodara city: Wind load As per IS: 875-Not designed for wind load, since earthquake loads exceed the wind loads. Earthquake load + As per IS-1893 Part 1) - 2002 Depth of foundation below round =: 2.5m Type of soil : Type Tl, Medium as per 15-1893 Allowable bearing pressure :200KNim* Average thickness of footing 0.9 m, assume isolated footing: Storey height Typical Boor: 5 m, Gi Floors GF. +5 upper floors Ground beams + To be provided at 100 mm below GL. Plinth level 206m Walls : 280 mm thick brick masonry wall Material Properties Concrete grade Steel ‘only at penphery. All components unless specified in design: M?5 grade all E.=5000,{f, Nimm?= 5000,/F, MNim* = 25 000 N/mm? = 25 000 MN/m*. For central columns up to plinth, ground floor and first floor: M30 E.=5000/7, Nimm?= 5000/7, MNin? = 27 386 N/mm’ = 27 386 MN/m’. HISD reinforcement of grade Fe 415 confirming to IS: 1786 is used throughout.