You are on page 1of 6

ASTM (American)

BDS EN (Bangladesh)
BS (British)
EN (European)
BIS (Indian)
ISO (international)
 Type I General Purpose Cement , OPC
 Type II Moderate heat/Moderate Sulphate
Resistance
 Type III High Early Strength
 Type IV Low Heat of Hydration
 Type V High Sulphate Resistance
A Air -Entraining
 LA Low Alkali
Blended Hydraulic Cement
Type IS Portland blast-furnace slag cement
Type IP Portland-pozzolan cement
Type P Portland-pozzolan cement
Type I(PM) Pozzolan-modified portland cement
Type S Slag cement
Type I(SM) Slag-modified portland cement
Type GU General use
Type HE High early strength
Type MS Moderate sulfate resistance
Type HS High sulfate resistance
Type MH Moderate heat of hydration
Type LH Low heat of hydration
Considering weather condition of
Bangladesh,
BSTI has adapted EN197-1:2000 standard
in 2003
in the name of
BDS EN 197-1:2003
And producing:
 Portland Cement
 Portland Composite Cement
 Portland Pozzolana Cement (Fly ash based
Cement Designation Notation Clinker G.G.B.S. Silica Pozzolana Fly ashes Burnt Limestone Minor
Type fume Natural Industrial Silic. Calcar. Shale additional
K S D P Q V W T L constit.
I Portland Cement I 95-100 - - - - - - - - 0-5
Portland Slag Cement II/A-S 80-94 6-20 - - - - - - - 0-5
II/B-S 65-79 21-35 - - - - - - - 0-5
Portland Silica Fume
Cement II/A-D 90-94 - 6-10 - - - - - - 0-5
II PortlandPozzolana II/A-P 80-94 - - 6-20 - - - - - 0-5
Cement II/B-P 65-79 - - 21-35 - - - - - 0-5
II/A-Q 80-94 - - - 6-20 - - - - 0-5
II/B-Q 65-79 - - - 21-35 - - - - 0-5
Portland Fly Ash II/A-V 80-94 - - - - 6-20 - - - 0-5
Cement II/B-V 65-79 - - - - 21-35 - - - 0-5
II/A-W 80-94 - - - - - 6-20 - - 0-5
II/B-W 65-79 - - - - - 21-35 - - 0-5
Portland Burnt Shale II/A-T 80-94 - - - - - - 6-20 - 0-5
Cement II/B-T 65-79 - - - - - - 21-35 - 0-5
Portland Limestone II/A-L 80-94 - - - - - - - 6-20 0-5
Cement II/B-L 65-79 - - - - - - - 21-35 0-5
Portland Composite II/A-M 80-94 < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 6 - 20 - - - - - - - - - - - - - - - - - - - - - - >
Cement II/B-M 65-79 < - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - 21 - 35 - - - - - - - - - - - - - - - - - - - - - - >
Blastfurnace III/A 35-64 35-65 - - - - - - 0-5
III Cement III/B 20-34 66-80 - - - - - - 0-5
III/C 5-19 81-95 - - - - - - 0-5
IV Pozzolanic Cement IV/A 65-89 - < - - - - - - - - - - 11 - 35 - - - - - - - - - - >- - - - 0-5
IV/B 45-64 - < - - - - - - - - - - 36 - 55 - - - - - - - - - - >- - - - 0-5
V Composite Cement V/A 40-64 18-30 < - - - - - - - - 18 - 30 - - - - - >
- - - - 0-5
V/B 20-39 31-50 < - - - - - - - - 31 - 50 - - - - - >
- - - - 0-5

You might also like