Chapter 1 ................................................................................ 4
Before Installing ..................................................................... 4
Product Package........................................................................... 5
Chapter 2 ................................................................................ 7
Installation Environment ....................................................... 7
Installation Environment .............................................................. 8
Chapter 3 ................................................................................ 9
System Configuration ............................................................ 9
Network Mode ............................................................................. 10
Standalone Mode ........................................................................ 11
Chapter 4 .............................................................................. 12
Installation ............................................................................ 12
Installation of Fixing Bracket..................................................... 13
Installation of other parts ........................................................... 14
External Cable Connection ........................................................ 15
Terminal Fixing ........................................................................... 18
Chapter 5 .............................................................................. 19
After Installation ................................................................... 19
After Installation.......................................................................... 20
4

Chapter 1
Before Installing

Product Package
5

Product Package

Item Shape Quantity Usage


Terminal 1 Access controller

Installation 1 Fixes the terminal.


Bracket

Adapter 1 Supplies power to the


terminal.

Power 1
Cord
6

Bolts 1 Fixes the terminal.

3 Fixes the installation


bracket.

Cable Door 3 Top : 1ea


Side : 2ea

S/W CD 1 AccessManager
Professional
Software CD
7

Chapter 2
Installation Environment
8

Installation Environment

Select the installation location considering the following, and get


consent from the user if needed.

① This product should be installed indoors. If installed outdoors, the


product must be protected from direct sunlight, snow, and rain.
② Cables must not be exposed and it is recommended that they be
buried. If this isn’t possible due to the environment, get consent
from the user before installing.
③ Plug in the power only after all cables are connected. While the
unit is plugged in, do not disconnect the cables or connect them
to other cables.
④ The product can be used more effectively if it is installed at a
convenient height and location. The recommended height for a
normal adult is 150cm from the ground to the center of the
terminal.
⑤ Input power for the system is AC 100~240V, 50/60Hz.

Note
If the power unit is not grounded, static electricity, etc may cause
problems.
Chapter 3
System Configuration

Network Mode

Standalone Mode
10

Network Mode

Terminals are connected by network. It can be remote control.

Server PC Client PC

Network (TCP/IP)

Terminal

Door opening S/W Lock

Figure3.1 Network Configuration


11

Standalone Mode

One terminals is used independently. All settings such as user


registration, deletion, and access control are performed in the
terminal alone.

Lock

Door opening S/W

Figure3.2 Terminal Configuration


12

Chapter 4
Installation

Installation of Fixing Bracket

Terminal Connection

External Cable Connection

Terminal Fixing
13

※ Install the product in the following order:


① Install the fixing bracket.
② Install other devices (such as lock and door switch).
③ Connect the external cable.
④ Fix the terminal.

Installation of Fixing Bracket


① Select a suitable installation location, and fix the fixing bracket
with the four bolts provided with the product.

Figure4.1 Installation of Fixing Bracket


14

Installation of other parts

☞ The following devices can be installed, refer to the table below for
instructions.
① Locking device
② Door-opening S/W

■ Lock Types and Specifications

Type Specifications Remarks


Deadbolt Input: DC12V, Voltage output,
Less than 1A Fail Safe/Secure Type
Electronic Magnetic Input: DC12V, Voltage output,
Lock Less than 1A Fail Safe/Secure Type
Electric Strike Input: DC12V, Voltage output,
Less than 1A Fail Safe/Secure Type
Auto Door * Maximum switching Contact point output
voltage: 220V DC, 250V
AC.
* Maximum switching
current: Less than 2A DC,
AC
☞Fail Safe Type: Unlocked, Opened upon emergency
☞Fail Secure Type: Locked, Closed upon emergency
15

External Cable Connection


※ Install the following cables to the terminal.
However, the network cable may not be connected upon
customer’s request.

1. Power & Door control cable


2. Network cable
3. Wiegand cable

4.3.1 Power & Door Control Cable Connection

Door-opening
S/W

Electric
Magnetic
Deadbolt Strike
Lock

☞ Caution
① Connect the cable to the correct ports.
② If connecting the cable to an automatic door, use the contact
point output and open the [JP2] port on the main board. In the
factory setting, the [JP2] port is connected by the jumper.
③ Some locks do not have door monitoring signals.
16

Deadbolt/Strike/Electronic Magnetic Lock


PIN
Function Fail Fail Door Door
No.
Safe Type Secure Type Monitoring Open
Open
8 (Gray) GND GND GND NO
Button
7 Door Open Open
(White) Button Button
6 Door
COMMON
(Blue) Monitoring
5
CONTACT_B VCC(12V)
(Orange)
4
COMMON
(Yellow)
3
CONTACT_A VCC(12V)
(Green)

Automatic Door
PIN
Function Normal Normal Door Door
NO
Open Close Monitoring Open
8 Open
GND NO
(Gray) Button
7 Door Open Open
(White) Button Button
6 Door
COMMON
(Blue) Monitoring
5
CONTACT_B Contact
(Orange)
4
COMMON Contact Contact
(Yellow)
3
CONTACT_A Contact
(Green)
17

JP2 is jumper for supplying power(12V) to the door


lock. If you use the external power supply, those
jumper must be removed before connecting the power.

4.3.2 Network Cable Connection (J3)


- When connecting the network cable, connect to Modular
Jack(RJ45).

Cabling
Housing Cable
PIN No. Function
1 TXP
2 TXN
RJ45, 8PIN UTP
3 RXP
6 RXN

4.3.3 Wiegand Cable Connection (J2)

PIN No. J19

1 (BLACK) GND

2 (WHITE) EXT_B

3 (GREEN) EXT_A

4 (YELLOW) Wiegand 1

5 (ORANGE) Wiegand 0

6 (RED) +5VDC

7 (Gray) Wiegand input 0

8 (Brown) Wiegand input 1


18

Terminal Fixing
① After the cables are connected, tidy the rest of the cables at
the rear of the terminal and place the terminal on the fixing
bracket as shown in Figure 4.2.

Figure4.2 Placing the Terminal on the Fixing Bracket

② Fix the terminal using the fixing bolts as shown in Figure 4.3.

Figure4.3 Fixing the Terminal


19

Chapter 5
After Installation

After Installation
20

After Installation

After finishing installation, check that it was done properly and


plug in the power.

Check if the lock and other devices are properly functioning as


described below. For more information, see “FingkeyAccess
Terminal Manual” and “AccessManager Professional User
Manual.”

① When power is supplied, the initial screen with


FingkeyAccess string and Time will appear.
② Select the Network -> Normal -> “Disable” in Admin
menu of Terminal to use the standalone mode.
③ Press the Admin button and select User -> “Register” to
register user information such as ID and fingerprint.(4-
digit user ID is set to the default
④ Perform fingerprint authentication peripherals such as a
locking device to proceed with the Test

Note
Fisrt registered user has administrator right therefore, you must
initialize all user data if installer and administrator are different.
21

When operating the terminal in network mode, install Access


Manager Professional and conduct the following test.

① Install the AccessManager Professional in the server PC.


Register the administrator and set initial configurations. (For
more information, see AccessManager Professional User
Manual)
② Select the Network -> Normal -> “Wireline” in Admin menu of
Terminal. (See FingkeyAccess terminal User Manual)
③ Set the network settings in the Terminal Admin menu.
④ Start the AccessManager and then register after check if the
terminal is connected.
⑤ Register a terminal user in the server PC and check that
authentication proceeds properly.
⑥ If there are no problems, delete both the server user and the
terminal user.