NOTES,
1 THIS DETAIL APPLIES FOR OPENINGS B"@ AND LARGER.
FOR SMALLER OPENINGS, BEND BARS OR ADJUST SPACING
OF REINFORCEMENT TO AVOID OPENING.
2 PLACE EXTRA BARS OF THE SAME SIZE AS THE
INTERRUPTED BARS AT EACH SIDE OF OPENING. QUANTITY
OF EXTRA GARS AT EACH SIDE SHALL EQUAL HALE THE
QUANTITY OF INTERRUPTED BARS EXCEPT WHERE NOTED
OTHERWISE,
3 PROVIDE ONE DIAGONAL BAR EACH SIDE OF OPENING wiTH
SIZE EQUAL TO MAIN REINFORCEMENT, TYBICAL EACH PACE
* WHERE INVERT OF OPENING IN WALL IS LESS THAN 44 BAR
DIAMETERS FROM TOP OF SLAB, EXTRA REINFORCEMENT ON
FAGH SIDE SHALL INCLUDE DOWELS EMBEDDED INTOSSLAS
METH STANDARD 90 DEGREE HOOKS TO SPLICE WK EXTRA
MERTICAL REINFORCEMENT. DOWELS SHALL ALSO SILL SE
PROVIDED BELOW OPENING.
5 WERE INVERT OF OPENING IN WALL OR SLAB IS CLOSER
OnAN 4 BAR DIAMETERS TO EDGE OF SLAB OF SOTTO
Prop. EXTRA DIAGONAL BARS MAY BE TERMINATED WO.
INCHES FROM EDGE OF SLAB OR BOTTOM OF WALL DOWe,S
QOLNOT HAVE TO BE PROVIDED TO SPLICE WITH DIAGONAE
BARS,
MD.TP.
Hone
FF
+
+
+
4.
+ + +
tet ttt
+
+
TYPICAL REINF AT OPENINGS
(HEAD Wierts)