CÁMARA SEPTICA DE DOBLE COMPARTIMIENTO

Dotación Población de Diseño Consumo Total


𝐶 = 120 𝑙𝑡⁄ℎ𝑎𝑏 /𝑑𝑖𝑎 𝑃𝑑 = 𝑃𝑎(1 + 𝑟)𝑛 𝐶𝑇 = 𝑃𝑑 × 𝐶
𝑃𝑑 = 340(1 + 1.50%)20 𝐶𝑇 = 458 × 120
𝑃𝑑 = 458 ℎ𝑎𝑏 𝐶𝑇 = 54960 𝑙𝑡/𝑑𝑖𝑎

Volumen Útil
𝑉 = 1.3𝑁(𝐶 × 𝑇 + 100 𝑙𝑓)
𝑉 = (1.3)(458)[(54960)(0.5) + 100 (1)]
𝑉 = 95264 𝑙𝑡

𝑉 = 95.264 𝑚3

Volumen
ℎ 𝑙𝑖𝑞 = 2.30 𝑚 𝑏 ≤ 2ℎ 𝐿 = 2ℎ 𝐴 = 𝑏×ℎ
𝑉 =𝑏×ℎ×𝑙 4.60 𝑚 ≤ 2(2.30) 𝐿 = 2(4.60) 𝐴 = 4.60 × 2.30

𝑏 = √𝑉⁄2ℎ 4.60 𝑚 ≤ 4.60 𝑚 𝐿 = 9.20 𝑚 𝐴 = 10.60 𝑚2

𝑏 = √95.264⁄2(2.30)

𝑏 = 4.60 𝑚

Dimensiones
𝑏 = 4.60 𝑚 𝐿1 = 2/3𝐿 𝐿2 = 1/3𝐿 ℎ1 = 2/3 ℎ 𝑙𝑖𝑞
𝐿 = 9.20 𝑚 𝐿1 = 2/3(9,20) 𝐿2 = 1/3(9,20) ℎ1 = 2/3 (2.30)
𝐿1 = 6.13 𝑚 𝐿2 = 6.13 𝑚 ℎ1 = 1.53 𝑚

Área de la Pared Divisoria


𝐴1 = 𝐴(10%) 𝐴2 = 𝐴(5%)
𝐴1 = 10.60(10%) 𝐴2 = 10.60(5%)
𝐴1 = 1.060𝑚2 𝐴2 = 0.53𝑚2
Área de boquete
ℎ𝑖 = 0.45 𝐴1 /𝐴𝑏𝑜𝑞 = 1.060/0.14 = 7.57 # DE BOQUETAS

𝑏𝑖 = 0.30 𝐴2 /𝐴𝑏𝑜𝑞 = 0.53/0.14 = 3.79 6

𝐴𝑏𝑜𝑞 = 0.14 𝑚2

#𝑏𝑜𝑞𝑢𝑒𝑡𝑎𝑠 × 𝑏𝑖 = 6 × 0.30 = 1.80m


𝑏 − 1.80 = 4.60 − 1.80 = 2.80𝑚
𝑆 = 2.80/7 = 0.40

FILTRO ANAEROBIO

Volumen Útil
𝑉𝐹𝐴 = 1.6 𝑁𝐶𝑇
𝑉 = 1.6(458)(120)(0.5)
𝑉 = 43968 𝑙𝑡

𝑉 = 43.968 𝑚3

Volumen
𝑉 =𝑏×ℎ×𝑙
𝑉
𝑙=
𝑏×ℎ
43.968
𝑙=
4.60 × 1.80
𝑙 = 5.31 𝑚