You are on page 1of 3
48 SINGLE CORE COPPER / ALUMINIUM XLPE INSULATED MEDIUM VOLTAGE CABLE SPECIFICATION : SPLN 43-5 N2xsy / NA2XSY Copper / Aluminium Conductor, XLPE Insulated, Copper Tape Screened, Water Blocking, PVC Sheathed Cable NOMINAL VOLTAGE : 3.6/6 (7.2) kV 6/10 (12) kV 8.7/15 (17.5) kV 12/20 (24) kV CONSTRUCTION Conductor e FEATURE : XLPE insulated single core cable are applied for installation : Indoors Outdoors Underground Cable Tray Stranded compacted circular copper or aluminium conductors. All internal interstices of conductor filled with water blocking compound which is specified to prevent ingress of water through conductor during storage, handling, installation and operating of the cable. Conductor Screen Extruded fully bonded semi conducting compound. Minimum thickness 0.5 mm and the maximum volume y of 5000 ohm-cm at 20 C and 25000ohm-cm at 90C. 49 Insulation Extruded XLPE with high degree of cross-linking, free frol contaminants, air voids and heat resistant by dry cured Insulation Screen Extruded semi-conducting compound. Minimum thickness 0.5 mm and the maximum volume resistivity of 5000 ohm-cm at 20°C and 25000 ohm-cm at 90°C. The screen is tightly fitted to insulation to exclude all air void and can be easily hand stripped on site. Conducting Water Blocking Layer ‘Semi-conductive water blocking tape provided over the insulation screen which will swell up under the influence of moisture or water. Metallic Screen Copper wires and copper tape applied over the conducting water blocking layer Copper tapes with minimum thickness 0.1 mm and maximum 0.3 mm Table 1. Minimum Total Cross Section of Metallic Screen na Water Blocking layer Non-conducting water blocking tape provided over the metallic screen which will swell up under the influence of moisture or water, Outer Sheath Extruded red PVC, suitable for exposure to sun-light or other local atmospheric environments and for the operating temperature of the cable. 50 SINGLE CORE COPPER / ALUMINIUM XLPE INSULATED MEDIUM VOLTAGE CABLE SPECIFICATION : SPLN 43-5 N2xsy / NA2XSY 12/20 (24) kV Copper / Aluminium Conductor, XLPE Insulated, Copper Tape Screened, Water Blocking, PVC Sheathed Cable ERS Conductor diameter (approx) mm 7a 82599 131 43 163° 187-209 237 266 303 343, Insulation dameter (approx) mm 197 NS 21 27 24 2S BA MS 37 we M2 Ms 5 Nominal sheoth thickness mn Py (Overall Cable ameter (approx) mm www Cable Net. Weight approx) afm Cu 1,000 1.290 1.522 1.810 2095 2445 2642 3410 4090 4950 6010 7,450 9.460 ‘AL 800 1005 1115 1,250 1375 1560 1.742 1,985 2200 2645 3070 3740 4415 eee ooo ooo GE ‘Al 0868 0.641 0443 0.320 0.253 0206 0,164 0,125 0.100 0.0778 0.0805 0.0869 0.0367 tndacanca perpen” __—_—03F3_ 0380 0388 0588 0527 0320 0307 0299 O28 0277 0271 0266 0263 OOO wHin 0788 0760 O76 0676 0488 Gawd Os13 OME OMB 0553 OND OSD 0508 AL 345 489 G81 9.19 1158 1443 17,76 2298 2867 3818 4760 5990 7596 ee ee eee ae een onemomenemenensnenene TT carrying eee ‘AL 180 217262328378 AS 48S S13. 452740 83H 87397. ‘eapacity ee 2S SSS ee ooo (Cu 205 20 ez AT a7 ae SHG waa AL 1S8 187 22k TaD YaST? aS7 77

You might also like