Bv25, MOBILE SURGICAL X-RAY SYSTEM BV25-S VOLUME 1 OF 2 SYSTEM INFORMATION MOBILE SURGICAL X-RAY SYSTEM BV25-S Manufacturing documents 8V25-S + Specification and Packing list BV25-S ~ Status Report with test and performance data, BV25-S - Licence for Practix-C tank AP. Certificate + List of Service manuals Service documentation BV25-S. = Volume 1: BV28-S information = Volume 2: Video information (@/93.0) ‘Copyright © 1099 Pips Motel Sytoms ltematona 8. ‘ALLAIGHTS RESERVED on o g > fy E G = 5 oS o a 9 i i > eR o < x > Zz < = Bv25 MOBILE SURGICAL X-RAY SYSTEM BV25-S FILING INSTRUCTIONS. ‘This manual should be filed in the set of Service documentation for the Mobile Surgical X-ray system BV25-S. {a/93.0) Copiht © 1995 Php Medel Systema ilomations 8. ‘ALLAIGHTS RESERVED 05 O ® a s a z g a > z c os a z = Sg & 5. a w = a ° 3 PROJECT NAME BIE SYSTEM : BV25 SPECIAL DUITSLAND COMM. ORDER +: 920301 886581 COLLO_| ITEM NUMBER DESCRIPTION NUMBER 454101 BV 25 MOBILE C-ARM X-RAY SYST. COMPACT MOBILE STAND ‘SET OF DOCUMENTATION ‘SET OF USER MANUALS MOBILE MONITOR TROLLY ORDER-DELIVERY-SHEET LINE NO ITEM NO ory TTEM DESCRIPTION 1010 999600022651 1 «B25. SPECIAL GERMANY oooood2105 220695 0002, MeCLOOL 1 BV25 SYSTEM 2001, 9a9600006451 1 «UNIVERSAL PART BV25 XTVES 2002 9g9600006471 1S SUPPL.Bv25 TBC 50H xIVES 2003 980775300001 = 1-—SHRL7S TV MON.ROT.SOHZ 2004 984910000201 = 11-—SMOUNTINGSET ONE 17" NON. 2005 980772102001 1 ‘DIGITAL, SCOFOFIX MDP 0002 989601010231 1 THERMAL PRINTER UP-910 1 COS-ORDER-NBR: 0000060505 PRINIDATE: 08/06/95 PAGE NER: END ! Status report Mobile Surgery System 1 System type: Hiev2s Gev2e Giev29 iev2i2 2 Alfa-nummeric code: MMC feof 12NC: 9896 Geo 2265/ 3. [Factory nr. : sB0 c kooky 4 — Mains voltage: 2ov 5 Mains resistance: 60 ma 6 — Mains frequency: Se Hz 7 Tested by: MLE ree pote: 14-b-g 8 High Voltage for Fluoroscopy kV setting on desk 100 kV 75 kV 40 kv Primary High Voltage PRHV ufo vi2sy Bvl i499 V kVp beam Fluoroscopy * KVFLUO 1o4S kv] DY y KV Mini-XPlus serial number: uo 8 Tube current Fluoroscopy kV setting on desk 100 kV. 70 kV 5O kV 40 kv mA reading on desk 3,0mA | 2,6 mA | 0,44 mA | 0,10 mA Measured current Normal Dose MAFLUO [2,98 ma [2,65mA lo, Y3mA [O08 mA KV setting on desk 100 kv 70 kV. 50 kV. 40 kV mA reading on desk 7.2mA | 6,2mA | 1,1 mA | 0,24 mA Measured current High Dose MAFLHD [7,11 mA| 610 mA| 404 malo,23mA 10 Tube current Radiography KV setting on desk 100 kV 70 kV. 40 kV mAs setting on desk (20 mA fixed) 80 mAs | 80 mAs | 80 mAs Measured current Radiography MARAD_ Ama [20,4 mA 4 mA 0,25 Volt (measured at SE19:MP4 and MPS) equals 1 mA. +) Cautior : Non invasive High Voltage measurment depends highly on waveform and filtration. The meesuring equipment should have a dedicated calibration. In case of doubt always check the primary high voltage on measuringpoint: SE37 +PRHV/-PRHV (See table below) WV new U gammy Fluoroscopy. U yrnny Exposure 100 kV 346 Vt 1 V onome a6aVE TV 80 KV Weve av 206VE8V GOK 2osV ESV 228Ve7V a0 KV Tso V5 ov WeoVe 5V 8322 000 05320 Status report Mobile Surgery System S00 [Pas W 14 Factory nr. ql S Bo C Eco 68 High Voltage for Radiography KV setting on desk 100 kV 75KV 40 kV Primary High Voltage PRHV 4641 VL 279>Vl 1556 Vv kV setting on desk 100 kV 80 kV 60 kV kVp beam Radiography KVRAD 1054 kV] Bru kV] S64 y Kv Mini-XPlus serial number: (Yo Exposure Time Radiography mAs setting on desk {20 mA fixed) 2mAs 20 mAs 80 mAs Exposure Time (ve ms|_too 5] _%, 94s Beam Alignment Fluoroscopy / Radiography Deviation Cfluo P+aQ R+S P+Q+R+S Fluoroscopy Fol 4 mm) (mm) tr omm| oa mm Fluoroscopy Fl mm mm mm mm Fluoroscopy F2 mm mm mm mm Deviation Crad 1Pi+i0) | IRI+ [P| +/O/+R/ +8) Radiography y mm| le mm) tf omm| le mm FO = Largest II format F1 and F2 not applicable for BV25/26 Visible Area it mode. FO F1 F2 Horizontal Lut mm mm mm Vertical TYZ mm mm mm FO = Largest Il farmat F1 and F2 not applicable for BV25/26 *) Caution: Non invasive High Voltage measurment depends highly on waveform and filtration, The measuring equipment should have a dedicated calibration. In case of doubt always check the primary high voltage on measuringpoint: SE37 +PRHV/-PRHV (See table page 1) Status report Mobile Surgery System 1 8822 000 08320 TEZ 50D Paae I Ta Factory nr. 8 Bo C Ee S94 18 Leakage Radiation at 105 kV and 65 Watt *) Radiation 2,3 wGvinr 18 Fluoroscopic entrance exposure rate *) Exposure rate SY 106 nGyimin 17 Dose Rate Fluoroscopy at 75 kV *} FO. Fa F2. Normal mode 0,26 pGyis uGy/s uGy/s Boost mode 0, 7B HGyis uGy/s uGyls FO = Largest Il format _F1_ and F2 not applicable for BV25/26 18 Reproduceability and Output *) Reproduceability C.0.V. ° Output BL Z_uGyintimAs 18 Fluoroscopy automatic condi Attenuation 20 mm Al + 2mm Cu FO. FL F2 Tube Voltage on display KV desk[ kv Kv ny Tube Current on display mA desk| 2, ¥ mA mA mA Attenuation 20 mm Al + 4mm Cu FO Fl F2. Tube Voltage on display KV desk| Og _kV Kv) wv Tube Current on display mA desk] 3g mA mA\ mA FO = Largest Ii format _F1 and F2 not applicable for BV25/26 208 Video Signals Black Level G3_mv Stabilized Video Out memory 00_mV ‘Set-up of clean circle te mv Contrast ratio memory BIA. spas ) Dose and Dose rate measured in Gray (Conversion factor uGy to wR = 114.5) 8322 000 05320 Status report Mobile Surgery System Teas Factory nr. $82 c EoosS) 20b Video Levels Memory Base attenuation 1mm cu 2mm Cu 2,5 mm CU Fluoroscopy base yzomv| yée mv] 300 mv Fluoroscopy +05mmcu| Sfe mV] r2g0 mVv| yp mv SUB base ztomv| 20 mila mv ‘SUB inject +O.3mmCu| ¢zo mV] po mV] ie mv MAX base mv MAX inject + 0,3 mm Cu mv MAP. base mV MAP inject + 0,3 mm Cu mv MAP cath base mv MAP cath + 2,5 mm Al mv 2: Resolution on TV-monitor IL mode: FO FL F2 At center 2 lpimm Ip/mm Ipimm ‘O = Largest Il format F1 and F2 not applicable for BV25/26 22 Picture Performance Il mode. FO. FL F2. Spots U FO = Largest Il format F1 and F2 not applicable for BV25/26 23. Earth Leakage current Normal condition LOS. g uA jingle fault condition (80,7 uA TET 8322 000 05320 Status report Mobile Surgery System: is _—_Tss00 Tass 4 Tat Factory nr. SBo_C_ E20 395 24 Earth Resistance l-container tro mo X-Ray tank tzo mo C-arm 122 mo Monitor 102 moa Trolley covers gs mo Stand covers tia ma Reference point: earth terminal of mains plug 25 Installed Software release Release number Rel: = 26 Installed Options System type pv25 | sv26 | ev29 | Bv2i2 Second Monitor for BV25 mmc 1031 | Image Storige Extension 34 images MMC 1041 | Video Data Unit mc i051 | Video Hard Copy Unit 1 moc 1061 | oa go a Video Hard Copy Unit 1/4 MMC 1087 a oa o [>] Image Storage 190 + Mosaic MMC 1112 a a a Angio Extension MMC 1122 a oO a Video Memory 32 images MMC 1131 a oa ao Video Memory 128 images MMC 1141 a a oa Remote Control MMC 1191 a a a Laser Aligment Tool MMC 1201 a oa oa Printer Sony UP910 MMC 1211| gp a o 5 THIS EQUIPMENT HAS BEEN INSPECTED AND TESTED BY THE LATEST AND MOST EXACTING METHODS AND WAS FOUND TO CONFORM TO SPECIFICATION. SHOULD ANY COMPLAINT ARISE PLEASE QUOTE SYSTEM SERIAL NO. CE 22, Status report Mobile Surgery System > 8322 000 05320 ET s Lao Tess al

You might also like