Project name: 1000 LPH RO Water type: NaCl, 2,000 ppm Membrane age: 1
Customer: VRINDAVAN Flux loss per year: 15.00% Safety factor: 1
Username: SAMBIT DE Salt passage increase: 20.00%
System - Pass1
RO feed Permeate Concentrate RO feed Concentrate Vessel Boost Back Average Perm.
# of vessels # of elements
flow flow flow pressure pressure DP pressure pressure flux TDS
m3/hr m3/hr m3/hr bar bar bar bar bar lmh ppm
Stage 1 1.00 2.00 1.33 0.61 0.73 18.56 18.28 0.28 0.00 0.00 38.48 37.44
Stage 2 1.00 2.00 0.73 0.39 0.33 21.28 21.17 0.11 3.00 0.00 24.83 144.35
Concentrate Permeate
Species Raw water Adjusted feed
Stage1 Stage2 Composite Stage1 Stage2 Composite
Ammonium 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Sodium 153.83 437.16 798.34 1,710.62 1,710.62 5.99 23.06 12.69
Potassium 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Magnesium 196.56 570.33 1,046.34 2,268.09 2,268.09 2.09 8.07 4.43
Calcium 256.38 743.95 1,364.89 2,958.69 2,958.69 2.70 10.44 5.74
Strontium 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Barium 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Fluoride 0.78 2.09 3.81 8.16 8.16 0.03 0.11 0.06
Chloride 797.98 2,397.52 4,397.08 9,522.06 9,522.06 10.55 40.79 22.41
Sulfate 303.67 829.93 1,524.34 3,313.22 3,313.22 0.98 3.79 2.08
Nitrate 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Carbonate 2.01 1.30 2.38 6.58 6.58 0.00 0.01 0.00
Bicarbonate 409.71 1,098.12 2,005.37 4,296.26 4,296.26 15.09 58.09 31.96
Boron 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Bromide 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
Silica 0.00 0.00 0.00 0.00 0.00 0.00 0.00 0.00
TDS 2,120.91 6,080.40 11,142.57 24,083.67 24,083.67 37.44 144.35 79.37
pH 7.72 6.92 7.00 7.04 7.04 5.34 5.93 5.57
Solubility - Pass1
Solubility calculation
Feed Concentrate
LSI 1.06 1.52
CaSO4 40.56 % 83.82 %
SrSO4 0% 0%
BaSO4 0% 0%
CaF2 165.65 % 756.65 %
SiO2 0% 0%
Stiff Davis Index 0.29 0.47
Warnings - Pass1
-Recovery exceeds recommended value of 20 % for Well Water (SDI<3) water type.
-Concentrate flow is less than the minimum value of 0.7 m3/hr for Well Water (SDI<3) water type.
_Disclaimer: LG Chem Design is intended to be used by persons having the requisite technical skill, at their own discretion and risk.
_When using LG Chem Design, it is the user's responsibility to make provisions against fouling, scaling and chemical attacks, to account for piping and valve pressure losses, feed pump suction pressure and permeate backpressure.
_LG Chem shall not be liable for any error or miscalculation in results obtained by using LG Chem Design.
_Because use conditions and applicable laws may differ from one location to another and may change with time,users are responsible for determining whether products are appropriate for their use.