You are on page 1of 5

F1-76 F1-105

Zone 2 Areamaster™ 250/400


Integrally ballasted floodlights for 400W, 250W, 150W, 100W, or 70W
high pressure sodium lamps; 400W, 250W, or 175W metal halide lamps;
or 400W, 250W, or 175W mercury vapor lamps. For Class I, Zone 2
AExnR, Groups IIA, IIB, IIC locations.

Applications
• Powerful, efficient weatherproof flood-
lights for use in areas where flammable
gases and vapors are present under
conditions defined as Zone 2. The
method of protection for the Zone 2
Areamaster 250/400 is Restricted
Breathing.
• Fixtures are also wall suited for use
in non-hazardous areas where sever

F
weather conditions and excessive mois-
ture is encountered.
• Typical applications include pulp and
paper mills, processing plants, oil re-
fineries, foundries, manufacturing plants
and storage areas.
Features
• Compact in size, attractively styled
Projected area:
contemporary design, rugged and de-
1.9 Sq. Ft.
pendable.
• Easy to install and service.
• Integral ballast; choice of multi-tap
for 120, 208, 240, or 277V lines, or for
480 lines.
• Yoke mount, zinc plated steel yoke
with architectural bronze POLYESTER
finish.
• Zone 2 fixtures include terminal
blocks. A seven point terminal block is
provided to facilitate wiring. Terminal
block accommodates wire size ranging
from #8 to #24 AWG.
• Cool operating temperatures translate
into long luminaire life.
Standard Materials
and Finishes
• Housing: one-piece pressure-cast
copper-free aluminum with architectur-
al bronze POLYESTER finish.
• Lens door: one-piece pressure-cast
copper-free aluminum with architectur-
al bronze POLYESTER finish. Secured
by four 1/4" Dia. captive stainless steel
slotted hex-head bolts.
• Lens: thermal-shock and impact
resistant glass. • Reflector: compound parabolic, dou- Compliances
• Gasket: heavy duty, high temperature ble segment, Alzak finished aluminum • UL 2279
®

silicone rubber, firmly seated. for optimum efficiency. • Class I, Zone 2 AEx nR IIC, IP66
• Socket: heavy duty, mogul base • Appleton aluminum products are pro-
porcelain with heavy gauge brass, nick- duced from a high strength copper-free
el plated, double lamp-grip screw shell (4/10 of 1% max.) alloy.
and spring loaded center contact.

Effective October, 2001 7770 N. Frontage Road


Copyright 2001 Printed in U.S.A. Skokie, Illinois 60077
PAGE 105
F1-106 F1-77
Class I, Zone 2
AEx nR IIC IP66
Zone 2 Areamaster™ 250/400
Integrally ballasted floodlights for 400W, 250W, 150W, 100W, or 70W
high pressure sodium lamps; 400W, 250W, or 175W metal halide lamps;
or 400W, 250W, or 175W mercury vapor lamps. Mogul Base Lamps.

Ordering Information

Line Yoke Mounting Supply Ambient Class I, Zone 2


Lamp Voltage Cat. No.’s Wire (°C) Temp (°C) Temp Code Temp. (°C)

High Pressure Sodium


400W HPS 120/208/240/277 G-AM771L-MT-Z2 105 40 T3 200
400W HPS 120/220/240 G-AM771L-XP-Z2* 105 40 T3 200
400W HPS 480 G-AM771L-48-Z2 105 40 T3 200
250W HPS 120/208/240/277 G-AM671L-MT-Z2 75 40 T4 135
F

250W HPS 120/220/240 G-AM671L-XP-Z2* 90 55 T3 200


250W HPS 480 G-AM671L-48-Z2 105 65 T3 200
150W HPS 120/208/240/277 G-AML471L-MT-Z2 75 40 T4 135
150W HPS 120/220/240 G-AML471L-GP-Z2* 90 55 T4 135
150W HPS 480 G-AML471L-48-Z2 105 65 T3 200
100W HPS 120/208/240/277 G-AML371L-MT-Z2 75 40 T5 100
100W HPS 120/220/240 G-AML371L-GP-Z2* 90 55 T4 135
100W HPS 480 G-AML371L-48-Z2 105 65 T4 135
070W HPS 120/208/240/277 G-AML271L-MT-Z2 75 40 T6 85
070W HPS 120/220/240 G-AML271L-GP-Z2* 90 55 T5 100
070W HPS 480 G-AML271L-48-Z2 105 65 T4 135
Metal Halide
400W MH 120/208/240/277 G-AM771H-MT-Z2 105 40 T3 200
400W MH 120/220/240 G-AM771H-XP-Z2* 105 40 T3 200
400W MH 480 G-AM771H-48-Z2 105 40 T3 200
250W MH 120/208/240/277 G-AM671H-MT-Z2 85 40 T3 200
250W MH 120/220/240 G-AM671H-XP-Z2* 105 55 T3 200
250W MH 480 G-AM671H-48-Z2 110 65 T3 200
175W MH 120/208/240/277 G-AM571H-MT-Z2 90 40 T4 135
175W MH 120/220/240 G-AM571H-XP-Z2* 105 55 T3 200
175W MH 480 G-AM571H-48-Z2 110 65 T3 200
Mercury Vapor
400W MV 120/208/240/277 G-AM771M-MT-Z2 105 40 T3 200
400W MV 220/240 G-AM771M-XK-Z2* 105 40 T3 200
400W MV 480 G-AM771M-48-Z2 105 40 T3 200
250W MV 120/208/240/277 G-AM671M-MT-Z2 85 40 T3 200
250W MV 220/240 G-AM671M-XK-Z2* 105 55 T3 200
250W MV 480 G-AM671M-48-Z2 105 65 T3 200
175W MV 120/208/240/277 G-AM571M-MT-Z2 75 40 T4 135
175W MV 220/240 G-AM571M-XK-Z2* 90 55 T3 200
175W MV 480 G-AM571M-48-Z2 105 65 T3 200

*50 Hertz. “T” Numbers represent the maximum surface temperature


for luminaries with AEx nR rating:
NOTE: For Class I, Div. 2 Areamaster
250/400, see catalog section Q. “T”
Number T1 T2 T3 T4 T5 T6
Temp.
Range 301-450 201-300 136-200 101-135 86-100 85
(°C)

To comply with AEx nR Requirements, all wiring entries must be sealed.

Effective October, 2001 7770 N. Frontage Road


Copyright 2001 Printed in U.S.A. Skokie, Illinois 60077
PAGE 106 PAGE 77
F1-78 F1-107
Zone 2 Areamaster™ 250/400
Accessories

Mounting Fittings and Accessories


Dimensions Description Cat. No. Dimensions Description Cat. No.

Crossarm 2-7/8"

Mounting Bracket Poletop Slip-Fitter


5"
Has 180° horizontal adjustment— Slip-fits 1-1/2" or 2" pipe size po-
degree marked. Facilitates mount- letop tenons. Includes floodlight
2-5/16" ing floodlight to crossarm or other yoke bolts, 3 locking bolts, and
3/8" flat surface, or to G-AM-8-WB. cord grip. Body is malleable iron-

F
Includes floodlight yoke bolts. 4-9/16"
zinc plated, chromate sealed, with
4-7/16" Malleable iron, zinc plated, chro- cast aluminum cap. Assembly has
mate sealed, architectural bronze 2" architectural bronze POLYESTER
POLYESTER finish. finish.
5/8" 2-1/2"
G-AM-8-CA G-SF20

5"
Pipe or Wall
4-7/8" Mount Bracket Top Visor
Used with G-AM-8-CA. Clamps to 16" 8-1/4" Easy to install with hardware sup-
1" to 2-1/2" pipe, vertical or hori- plied. Aluminum, with architectural
3" 5-1/4"
zontal, or mounts on flat surfaces. bronze POLYESTER finish.
5-1/2" Includes U-bolt and crossarm
G-AM-6-V
bracket bolts. Malleable iron, zinc
plated, chromate sealed, with ar-
4-1/2"
chitectural bronze POLYESTER
finish.
G-AM-8-WB

16" Vandal Shield


Replacement Lens
UV stabilized polycarbonate, with
installation hardware and instruc- 604249003
12-7/8"
tions.
G-AM-6-VS

Effective October, 2001 7770 N. Frontage Road


Copyright 2001 Printed in U.S.A. Skokie, Illinois 60077
PAGE 78 PAGE 107
F1-108 F1-79
Photometric Data —
Zone 2 Areamaster™ 250/400
Typical Footcandle Values ♦

MH 45˚

Mtg. Ft. Cdles for Iso-Footcandle Lines Mtg. Ft. Cdles for Iso-Footcandle Lines
Ht. A B C D E F Ht. A B C D E F

3.0 F For 175W MH lamps, multiply


400W HPS 250W MH FC values by 0.64.
E
Distance in terms of mounting height ♦

2.5
60' 3.27 2.74 1.82 0.92 0.37 0.18 60' 1.40 1.00 0.60 0.35 0.20 0.10
D
2.0 50' 4.74 4.00 2.90 1.37 0.52 0.27 50' 2.00 1.40 0.90 0.46 0.29 0.15
C
F

B
40' 7.65 6.28 4.38 2.27 0.82 0.43 40' 3.30 2.18 1.40 0.80 0.45 0.22
1.5
A
30' 3.10 10.92 7.83 3.47 1.45 0.77 30' 5.90 4.70 2.40 1.30 0.80 0.41

1.0 20' 28.22 25.55 17.37 7.28 3.46 1.82 20' 10.40 8.80 5.60 3.20 1.90 0.90

0 250W HPS 400W MV

.5 60' 1.96 1.64 1.09 0.55 0.22 0.11 60' 1.30 1.02 0.69 0.46 0.28 0.19

0 .5 1.0 1.5 2.0 50' 2.84 2.40 1.74 0.82 0.31 0.16 50' 1.86 1.49 1.02 0.65 0.39 0.28
Distance in terms of mounting height ♦
40' 4.58 3.76 2.62 1.36 0.49 0.26 40' 2.98 2.32 1.52 1.04 0.63 0.43

30' 7.85 6.54 4.69 2.08 0.87 0.46 30' 4.65 4.09 2.79 1.95 1.15 0.78

MH 20' 16.90 15.30 10.40 4.36 2.07 1.09 20' 11.25 9.49 6.70 4.37 2.42 1.58
45˚

400W MH 250W MV

3.0 60' 2.32 1.66 1.00 0.58 0.33 0.17 60' .70 0.55 0.37 0.25 0.15 0.10
L
Distance in terms of mounting height ♦

50' 3.32 2.32 1.49 0.76 0.48 0.25 50' 1.00 0.80 0.55 0.35 0.21 0.15
K
40' 5.48 3.62 2.32 1.33 0.75 0.36 40' 1.60 1.25 0.82 0.56 0.34 0.23
2.0 J
I
30' 9.79 7.80 3.98 2.16 1.33 0.68 30' 2.80 2.20 1.50 1.05 0.62 0.42
H
G
20' 17.26 14.60 9.30 5.31 3.15 1.49 20' 6.05 5.10 3.60 2.35 1.30 0.85
1.0

Mtg. Ft. Cdles for Iso-Footcandle Lines


.5 Ht. G H I J K L

70W HPS For 100W HPS lamps, multiply footcandle


values by 1.5.
1.0
0 1.0 2.0 3.0
10' 10.00 5.00 2.50 1.00 0.50 0.25 For 150W HPS lamps, multiply footcandle
Distance in terms of mounting height ♦ values by 2.5.
20' 2.50 1.00 0.50 0.25 0.10 0.05

♦ (i.e., ratio of distance to height. Example: 30' 1.00 0.50 0.25 0.10 0.05 0.02
@ 20' mounting height, 1 means 20'; 2
means 40', etc.)
♦ Photometric charts available on request.

Effective October, 2001 7770 N. Frontage Road


Copyright 2001 Printed in U.S.A. Skokie, Illinois 60077
PAGE 108 PAGE 79
F1-80 F1-109
Zone 2 Areamaster™ 250/400
Electrical Specifications

Electrical Specifications
Lamp Lamp Line Type of Starting Operating Total Lamp Lamp Line Type of Starting Operating Total
Watts Type Voltage Frequency Ballast Amps Amps Watts Watts Type Voltage Frequency Ballast Amps Amps Watts

70 HPS 120 60 HX-HPF 0.90 0.82 94 250 MH 120 60 CWA 1.20 2.60 294
208 60 HX-HPF 0.50 0.48 94 208 60 CWA 0.65 1.50 294
240 60 HX-HPF 0.44 0.41 94 240 60 CWA 0.60 1.30 294
277 60 HX-HPF 0.35 0.36 94 277 60 CWA 0.50 1.12 294
480 60 HX-HPF 0.21` 0.21 94 480 60 CWA 0.30 0.65 298
120 50 HX-HPF 1.08 0.81 97 120 50 CWA 2.00 2.50 285

F
220 50 HX-HPF 0.59 0.49 97 220 50 CWA 0.94 1.30 285
240 50 HX-HPF 0.54 0.45 97 240 50 CWA 0.85 1.25 285

100 HPS 120 60 HX-HPF 1.30 1.15 130 400 MH 120 60 CWA 3.25 4.00 458
208 60 HX-HPF 0.76 0.67 130 208 60 CWA 1.90 2.30 458
240 60 HX-HPF 0.66 0.58 130 240 60 CWA 1.65 2.00 458
277 60 HX-HPF 0.60 0.50 130 277 60 CWA 1.40 1.75 458
480 60 HX-HPF 0.33 0.29 130 480 60 CWA 0.85 1.00 462
120 50 HX-HPF 0.90 1.20 130 120 50 CWA 2.70 4.10 480
220 50 HX-HPF 0.50 0.65 130 220 50 CWA 1.50 2.20 480
240 50 HX-HPF 0.45 0.60 130 240 50 CWA 1.30 2.00 480

150 HPS 120 60 HX-HPF 2.00 1.65 188 175 MV 120 60 CWA 1.65 1.80 200
208 60 HX-HPF 1.16 0.95 188 208 60 CWA 0.95 1.00 200
240 60 HX-HPF 1.00 0.83 188 240 60 CWA 0.65 0.90 200
277 60 HX-HPF 0.86 0.75 188 277 60 CWA 0.72 0.78 200
480 60 HX-HPF 0.50 0.42 188 480 60 CWA 0.44 0.44 200
120 50 HX-HPF 1.50 1.60 188 120 — — — — —
220 50 HX-HPF 0.85 0.90 188 220 50 CWA 0.90 1.00 210
240 50 HX-HPF 0.75 0.80 188 240 50 CWA 0.85 0.92 210

250 HPS 120 60 CWA 1.60 2.70 295 250 MV 120 60 CWA 2.40 2.50 285
208 60 CWA 0.95 1.50 295 208 60 CWA 1.40 1.50 285
240 60 CWA 0.80 1.30 295 240 60 CWA 1.20 1.25 285
277 60 CWA 0.70 1.15 295 277 60 CWA 1.00 1.10 285
480 60 CWA 0.40 0.65 295 480 60 CWA 0.60 0.62 285
120 50 CWA 1.85 2.75 300 120 — — — — —
220 50 CWA 0.95 1.44 300 220 50 CWA 1.40 1.40 290
240 50 CWA 0.95 1.44 300 240 50 CWA 1.28 1.28 290

400 HPS 120 60 CWA 2.70 3.80 457 400 MV 120 60 CWA 3.40 3.90 454
208 60 CWA 1.70 2.20 457 208 60 CWA 2.00 2.20 454
240 60 CWA 1.40 1.90 457 240 60 CWA 1.70 1.95 454
277 60 CWA 1.30 1.70 457 277 60 CWA 1.50 1.70 454
480 60 CWA 0.70 1.00 457 480 60 CWA 0.95 0.98 454
120 50 CWA 3.70 4.00 465 120 — — — — —
220 50 CWA 1.85 2.00 465 220 50 CWA 1.75 2.20 450
240 50 CWA 1.85 2.00 465 240 50 CWA 1.61 2.00 450

175 MH 120 60 CWA 1.30 1.80 210


208 60 CWA 0.75 1.04 210
240 60 CWA 0.65 0.90 210
277 60 CWA 0.55 0.80 210
480 60 CWA 0.35 0.45 210
120 50 CWA 1.70 1.90 210
220 50 CWA 0.80 1.10 210
240 50 CWA 0.80 1.10 210

Effective October, 2001 7770 N. Frontage Road


Copyright 2001 Printed in U.S.A. Skokie, Illinois 60077
PAGE 80 PAGE 109