You are on page 1of 2

HSB-E11 sensor barriers

Economical

Economical units offer a minimal


installation length and a simple
sensor system monitors the
passage area by offering single HSB-E11
passage in both directions.

Standard units HSB-E11


50 -3/16"
Note: Description of single unit (1290)

Interlock height 37-3/16" (945)

35-7/16"

37-3/16"
Interlock length 50-13/16" (1290)

(900)

(945)
Passage width 25-9/16" (650)
Total width 42-1/8" (1070)
Housing, base columns, AISI 304 Ø2-3/8" (Ø60) stainless steel tube with 3/8" (10)
guiding elements toughened safety glass panel and AISI 304 stainless steel
handrail with integrated sensor system. 42-1/18"
(1070)
ADA compliance 36" (915) width available.
31-7/8"
Barrier elements Two door leaves made of transparent polycarbonate, upper edge (810)
3-7/16" (900).
Swinging area monitored by separation sensors. 25-9/16"
(650)
Security Passage area monitored by simple sensor system with our
shortest installation length (simple level of single passage
monitoring in both directions).
5-1/8" 5-1/8"
Finish Stainless steel semi-gloss smooth finish. (130) (130)

Safety Low energy drive with energy content less than 1.18 lb/ft.
Function Type 2–power assisted motion; two servo-positioning drives/
electrically controlled in both directions.
Drives Integrated in the swing tube.
Operating modes Optical.
Normally closed.
Normally opened. (Barriers close on tailgate event.)
Electrical equipment Control system and power supply integrated in the unit.
Power supply 110 – 230 VAC, 50/60 Hz. 368 VA
Standby power consumption 17 VA
Standard adjustment in case Door leaves move freely.
of power failure
Installation Dowelled on finished floor level, FFL.
Not suitable for outdoor installation.
Protection classes Housing IP32, components conducting supply voltage IP42.
Entrance systems
Subject to change without notice
dormakaba HSB-E11 sensor barriers

HSB-E11
Installation drawings
inside

37" (940) 46-7/8" (1190)


PW =
PW = 25-9/16" (650) PW = 36" (915) 25-9/16" (650) PW = 36" (915)

50-13/16" (1290)
22-13/16"
35-7/16" (900)
37-3/16" (945)

(580)

48" (1220)
5" (127)
12-5/8"
(320)

30-15/16" (785) 40-3/4" (1035)

5-1/8" (130)
5-1/8" 31-7/8" (810) 41-3/4" (1060) 5-1/8"
(130) 89" (2260) (130)

outside

50-13/16" (1290)

for anchoring

/2"
35-7/16" (900)
37-3/16" (945)

1-1 )
0
( 0 uit
1
nd
1-9/16" (40)

co
area
Ø3-1/8" (Ø80)
FFL for conduits
3-9/16" (90)

2" (50)

5-1/8" (130)

handrail
1/ 7/8"
(1 2"
co 2.7) (22.5)
nd
ui
t
4-5/16" (110)
1-3/8"
(35)

2-3/4" (70)

for anchoring

flange plate
Ø5-1/2" (Ø140)
EO 8.18

dormakaba USA Inc. Note


Dimensions shown as inches
Dorma Drive, Drawer AC followed by millimeters; for
Reamstown, PA 175675 example, 1" (25).
844.SPECNOW
www.dormakaba.us

You might also like