You are on page 1of 2
the Fire Protection centre A Great Deal to Offer FM Flow Meters Data Sheet METAL IDENTIFICATION BUTT WELD ENDS AG Steel (2"” - 10” Zinc Plated) eo erik a yuqg22oy BRASS THREADED ONLY Accuracy ~ +1% 1h" -616 aur 2" -685 4 METAL IDENTIFICATION TAS GROOVED ENDS Se ae) ret aes bd size 746 766 744 3 715 5 743 6 8 750 755 750 12 Reaqaaagn WELD-NECK FLANGES METAL joeNTINCATION RAISED FACE “sl gee ese aia) ben er) Accuracy ~ +1% BSeqaran -ingons Woy, Foxhil nutri state Scunthorpe Nom incoinahire, ONS BC) fe tection centre ta Regitres in non Ho, 0708508 Vt No. 279 11820 moll slest@ireprotectoncente.com Website rr Ipedoacente co.uk aon the Fire Protection centre A Great Deal to Offer = — RATING 500 PS! — (BUTT WELD, GROOVED ENDS & 300 # FLANGED) — RATING 275 PSI — (FOR 150 # FLANGED UNITS ONLY) A CALIBRATED VENTURI AND ATTACHED GPM METER INSTALLED ON THE DISCHARGE OF A FIRE PUMP TO ACCURATELY DETERMINE PUMP PERFORMANCE. 4'h” DIAL METER IS SHIPPED FOR MOUNTING ON VENTURI BRACKET. IF METER IS TO BE REMOTE MOUNTED. CONSULT FACTORY ON SPECIAL HOSE LENGTHS, LISTED BELOW ARE THE MOST COMMON MODEL “K” FM APPROVED PUMP GPMILINE SIZE COMBINATIONS OF FIRE PUMP TEST METERS. DUAL LPMIGPM SCALES AVAILABLE. PUMP VENTURI SYSTEM PIPE | METER RANGE WELDED or GROOVED “FLANGED VENTURI LENGTH Gen MODEL NO. SIZE _| MIN. & MAX. GPM VENTURI LENGTH 1508 (RF) 3008 (RF) 25 K-25-1/: (616) Ve" 12.5-50 Threaded only 3°" = = 50. K-50-2 (685) z 25-100. Threaded only 47). = = 100 K100-2'/; (746) 2" 50-200 3” (WELD) 4” Evia 10” 150 K-150-3 (766) od 75-300 3°" (WELD) 47%" s 200 | K-200-3 (766) a 100-400 ‘Sur (WELD) 4" a 250 K-250-4 (744) a" 125-500 3" (WELD) 324" Oi" 300 _| _K-300-4 (744) a 150-600 37 (WELD) 3°" oa 450 K-450-4 (744) a 225-900, Bi" (WELD) 37." Oi" 500. K-500-5 (715) Ss” 250-1000 _ Lu 12” 750 K-750-6 (743) s 375-1300 & 13”, 1000. K-1000-6 (743) s 500-2000. & 43”, 1250 K-1250-6 (743) 6 625-2500. Ss 13", 1500 K-1500-8 (750) 8” 750-3000 Tv 15”, 2000 K-2000-8 (750) ss” 4000-4000, re 45” 2500 K-2500-8 (750) 8" 1250-5000 7 15” 3000 K-3000-8 (750) 8 4500-6000. z” 15”, 3500 | K-3500-10 (755) 10" 1750-7000 e 16" 4000 K-4000-10 (755) 10" 2000-8000 a 16” 4500 K-4500-10 (755) 10" 2250-9000 8" 16” 5000 K-5000-12 (750) 12" 2500-10000 12" 21" Re Sareaone “8 Buerty Th ‘OSY oF indicating Buttery sucaesTeo : are By-Pass Val ae ERM PIPING aero «B= hg QO py oimcrant 1 ! fe aie ko _| Gere __4f Min. Sraigh pe Diameters same ino size as Vertu | O54 ave ie “A OSY Valve Supply trom ee erie 5» —¥ © 2 by . Reserve FIRE PUMP. To System OPERATING INSTRUCTIONS FOR GERAND FIRE PUMP TEST METER 1, Close System OSY Valve “A” Close vent valves after air purging, 2. Open OSY By-Pass Valve and “B” Buttertly Throttie Valve. 4. Start Fire Pump and read meter in GPM. 3, Purge meter located on Venturi as follows: ‘Open station shut-off valves (below meter) and vent valves (above meter). When a steady stream of water is passing through each plastic hose, meter is purged of air. aon 5. Refer to pump GPM requirement and adjust throttle valve for this requirement 6.Alter test. open OSY Valve “A and close By-Pass and "8 Valves. ax cao 65 200 31 ‘idesons Way, shi industri Estate, Seurthorpe Hort inolashie, ONS 8) Fee Protection Centre it eghstred in England No. 03758539. VAT Mo. 279 1182 60 ‘eephone 01724 854199 moll sles iveproteesoneentrecom Website wmaulpedstcentre.couk

You might also like