DRUM TYPE MAIN ANCHORAGE FOUNDATION

(Left Bank / On Soil)

F I N A L I N P U T D A T A
=============================

Number of Main Cables, nm : 4 Nos


Main Cable Tension, Tm : 971.19 kN
Handrail Cable Tension, Th : 253.20 kN
Cable Inclination, áf : 12.38 deg

Sub-soil Friction Angle, è1 : 28.00 deg


Sub-soil Unit Weight, â1 : 19.00 kN/m3
Back-soil Friction Angle, è2 : 27.00 deg
Back-soil Unit Weight, â2 : 18.00 kN/m3
Back Slope Angle, í : 15.00 deg
Front Slope Angle, î : 17.00 deg
Permissible Ground Bearing Pressure, åperm : 250.00 kN/mý

Back Height, H1 : 3.00 m


Front Height, H2 : 1.80 m
Breadth, B : 7.00 m
Length, L : 5.00 m

Loads on Foundation Top, A : 0.00 kN


C.G. Distance of Additional Load, a : 0.00 m

Active Soil Height, ha : 2.70 m


Soil Height in Front, hp : 1.60 m
Ground Water Height, hw : 0.00 m
Length of Influence Line, Linfl : 17.75 m
Front Soil Load, qload : 0.00 kN/mý

F I N A L R E S U L T S
=========================

Volume, V : 111.55 m3
Base Inclination, à : 9.73 deg
Resultant Vertical Load, Rv : 2759.82 kN
Resultant Horizontal Load, Rh : 1328.78 kN

Inclination of Resultant Force, ër : 25.71 deg


Safety against Toppling, Ft : 3.10 /
Distance to Resultant Force, B*/2 : 2.31 m

Maximum Ground Bearing Pressure, åmax : 167.26 kN/mý


Safety against Sliding, Fsl : 1.86 /
Safety Against Shear Failure, Fbc : 2.11 /
Number of Reinforcement Bar (dia.16 mm), N : 9 Nos