You are on page 1of 2

Introduction This design calculation pertains to calculation of Base Slab,all force taken from staad module.

Z-DIR IN STAAD UP
PLATE
Y-DIR

X-DIR
DESIGN OF BASE SLAB RAFT CF6

Grade of Concrete = M 35
Grade of Steel = Fe 500
Min clear cover = 50 mm

Safe bearing capacity (S.B.C)


2
Normal case (gross S.B.C at the depth of 3.5m) 400.00 kN/m
2
Seismic case (+ 25.00% ) 500.00 kN/m

2
Over burden pressure 0x 18 = 0 kN/m

BASE PRESSURE CHECK

Horizontal Vertical Horizontal


Node L/C Fx N/mm2 Fy N/mm2 Fz N/mm2
Max Px 872 299 1.0DL+1.0LL0 0.164 0
2
Min Px 872 299 1.0DL+1.0LL0 0.164 0 Max= 0.235 N/mm
2
Max Py 2984 301 1.0DL+1.0LL0 0.235 0 Min= 0.064 N/mm
Min Py 3040 301 1.0DL+1.0LL0 0.064 0
Max Pz 872 299 1.0DL+1.0LL0 0.164 0 Max pressure = 235 kN/m2 OK
2
Min Pz 872 299 1.0DL+1.0LL0 0.164 0 Mini pressure = 64 kN/m OK

SEISMIC CASE
Horizontal Vertical Horizontal
Node L/C Fx N/mm2 Fy N/mm2 Fz N/mm2
Max Px 872 302 1.0DL+1.0WL0 0.161 0
Min Px 872 302 1.0DL+1.0WL0 0.161 0 Max= 0.309 N/mm2
Max Py 2984 336 1.0DL-1.0EQX
0 0.309 0 Min= 0 n/mm2
Min Py 3040 335 1.0DL+1.0EQZ
0 0 0
Max Pz 872 302 1.0DL+1.0WL0 0.161 0 Max pressure = 309 kN/m2 OK
2
Min Pz 872 302 1.0DL+1.0WL0 0.161 0 Mini pressure = 0 kN/m OK
Result from staad
PLATE L/C SQX SQY MX MY MXY
Max Mx 169 20 (WL+DL+EQX)*1.5
-0.04 -0.291 258.957 37.539 44.387
Min Mx 198 22 (WL+DL-EQX)*1.5
-0.012 -0.154 -208.28 -35.784 36.918
Max My 161 22 (WL+DL-EQX)*1.5
-0.259 -0.295 103.266 41.888 9.825
Min My 15 21 (WL+DL+EQZ)*1.5
-0.008 0.011 -7.198 -57.047 46.886

Top Bottom
X dir Y dir X dir Y dir
Staad Moment, Mu KNm 208.28 57.047 258.957 41.888
Shear force per meter KN 346.3 224.2 190.2 180.4
Thickness of base slab (mm) = 750 750 750 750
Dia of Bar 1 mm 12 12 12 12
Spacing of Bar 1 mm 125 125 125 125
Dia of Bar 2 (mm) = 0 0 0 0
Spacing of Bar 2 (mm) = 125 125 125 125
Ast1 (mm2/m) 905 905 905 905
Ast2 (mm2/m) 0 0 0 0
2
Total (Ast1+Ast2) (mm /m) 905 905 905 905
Steel % = 0.130 0.130 0.130 0.130
No. of Layer 1 1 1 1
Material Data
Charecterstic strength of reinf. (fyk) MPa Fe 500 Fe 500 Fe 500 Fe 500
Partial factor for steel (γs) 1.15 1.15 1.15 1.15
Design yield strength of reinf. (fyd=fyk/γs) MPa 434.8 434.8 434.8 434.8
Modulus of Elasticity of Steel (ES) GPa 200.0 200.0 200.0 200.0
Charecterstic compressive strength of concrete (fck) MPa M 35 M 35 M 35 M 35
α 0.670 0.670 0.670 0.670
Concrete material factor (γm) 1.500 1.500 1.500 1.500
Design value for concrete compressive strength (fcd= αfck/γm) MPa 15.63 15.63 15.63 15.63

Strength of the section (*Moment Resistance)


Effective depth of section (d=D-c-φ/2) mm 694 694 694 694
λ 0.80 0.80 0.80 0.80
η 1.0 1.0 1.0 1.0
Depth of nuetral axis from compression flange ( x ) mm 31.5 31.5 31.5 31.5
Depth of stress block (λx) mm 25.2 25.2 25.2 25.2
Stress on stress block (η fcd) N/mm2 15.6 15.6 15.6 15.6
Total Compression Force (FC=λxηfcdb) KN 393.4 393.4 393.4 393.4
Total Tension Force (FS=fyd At) KN 393.4 393.4 393.4 393.4
Diff (FC-FS) 0 0 0 0
Depth of Lever arm (z=d-λx/2) mm 681.4 681.4 681.4 681.4
Moment of Resistance (Fc z) KNm 268 268 268 268
Status Ok Ok Ok Ok
M/Mu 0.78 0.21 0.97 0.16