Precise measurement.

Reliable qualification.

Precision measurement technology and services for cleanrooms. From Testo.


Sustained norm-compliant conditions
Unique services for your cleanrooms

In order to guarantee and maintain the purity of cleanrooms, you need exact measurements: With instrumentation and
services from Testo. They help you not only with the reliable qualification of your cleanroom for demanding production and
laboratory conditions. They also ensure you the long-term security of a constant cleanroom environment according to your
requirements and in compliance with the valid norms.

All OK: According to DIN ISO 14644 With the highly precise Testo measuring instruments, you
Testo offers you a norm-compliant measuring instrument monitor temperature, air humidity, differential pressure and
portfolio for the most demanding requirements in ventilation air flow velocity. Together with the monitoring systems for
and air conditioning in cleanrooms. You can be sure of temperature, relative air humidity and differential pressure,
having your critical processes in production or laboratories with Testo you always have an eye on all critical data
clean and under control at all times. concerning your cleanroom.

Air conditioning and ventilation:


Exactly under control
Whether qualification or re-qualification: Testo measuring
instruments and services for cleanrooms make sure that
your air quality complies with the norm within the
prescribed time intervals.

2
Your benefits from Testo's cleanroom
services
DIN ISO 14644-3:2005 Cleanrooms and Clean Zones –
• Calibrated measuring instruments with long-term Part 3: Test Methods
stable probes help you to maintain your defined Cleanrooms and their ancillary clean areas ensure regulation
cleanroom conditions exactly and permanently. of airborne contamination to degrees which are suited to
• You increase process security thanks to reliable the implementation of contamination-sensitive activities.
measurements with a high level of accuracy. The products and processes which benefit from the
• Necessary measurements can be reliably carried out regulation of airborne contamination include those in the
with optimally tailored measuring instruments. aeronautics and spaceflight, microelectronics,
• User-optimized instruments save working time pharmaceutical, medical technology, health and food
thanks to efficient and simple measurement industries. This part of ISO 14644 presents test procedures
procedures. which can be used to characterize cleanrooms, as they are
• Tailor-made services for the qualification of your described and set down in other parts of ISO 14644.
cleanrooms as well as measuring instrument
calibration fulfil all your wishes.

3
Critical processes demand
precise measurement technology
Overview of important 1 Temperature and 2 Differential pressure measure-
humidity testing ment of rooms and filters
measurements
According to DIN EN ISO 14644-3, According to DIN EN ISO 14644-3,
In order to operate your cleanrooms in
the ability of the ventilation system of the minimum positive pressure of the
compliance with the norms, basic
a cleanroom to maintain the air tem- cleanroom in relation to the
measurements must be carried out
perature and air humidity (given as rel- surroundings (5 to 20 Pa) must be
precisely and reliably with calibrated
ative humidity) within the limit values measured, in order to ensure that
measuring instruments. Because in the
necessary for the application must be particles are prevented from entering
end, it is not only about complying
tested. In addition to this, the light in- the cleanroom. In order to determine
with the norm, but also about the first-
tensity and sound level in the clean- the degree of contamination of the
class quality of your products and
room can be measured. The demands filter, its differential pressure must also
processes.
made of the measuring instrument are be measured. The measuring
When it comes down to it, you
specified in DIN EN ISO 7726, and re- instrument must have a measuring
depend on precision in
quire, for example, a measurement un- range of 0 to 50 Pa, a resolution of
application. With measuring
certainty of max. ± 2 %RH in a 0.5 Pa and a measurement uncertainty
instruments from Testo.
humidity measuring instrument. of max. ± 5 %.

4
3 Air flow testing 4 Measurement in a 5 Monitoring of temperature,
and air exchange rate laminar flow cabinet humidity and pressure
For the air flow test according to DIN DIN EN 12469 demands the testing of DIN EN ISO 14644 demands
EN ISO 14644-3, the air flow velocity in air volume flow and ventilation ratio. metrological observation for proof of
cleanrooms with low-turbulence flow Anemometers with suitable measuring the performance of a plant. The
and with turbulent mixed flow must be ranges and sensitivities are required in continuous monitoring of temperature,
determined. The total volume flow rate order to conduct measurements of air humidity and pressure help to ensure
can be used to determine the air flow velocity also at low velocities. Air product quality and to document it in
exchange rate in a system with entry flow through the HEPA filter, the accordance with the norms. Depending
turbulent mixed flow. The individual illumination and the noise level should on the use of the cleanroom, further
requirements for hot wire anemometers, also be measured. norms such as EU-GMP Guideline
vane anemometers and volume flow Annexe 1 can also be applied.
hoods are defined in DIN EN ISO
14644-3.
Precision measurement technology for cleanrooms from Testo

The right instrument for every


measurement
1 Temperature, humidity, Lux, 2 Differential pressure 3 Air flow testing,
sound air exchange rate

testo 480 - climate measuring instrument testo 420 – differential pressure testo 420 – volume flow hood
Record, analyze and document all rele- measuring instrument Particularly high measuring accuracy at
vant environmental parameters with just For precise differential pressure measure- swirl outlets thanks to volume flow
one multifunction instrument! ment up to 1.2 hPa straightener
• Intelligent calibration concept with zero-error • Handy instrument featuring a large display • Precise measurement of
display and user-friendly menu guidance volume flow up to 3,500 m3/h,
• Professional PC software for evaluation and • The automatic zeroing even in turbulent flows
documentation ensures higher accuracy • 2.9 kg lightweight, quick set-up
• Accessories: Digital probes allow for low pressures. • App connection: Create and
direct processing of the measure- EUR XXX.XX send reports directly on site
ment value in the probe Order no. 0560 0420 EUR XXX.XX
• Accessories: Wireless testo fast Order no. 0563 4200
printer testo 480 - climate measuring instrument
The allrounder with integrated Hot wire probe (Ø 10 mm, for testo 480)
EUR XXX.XX differential pressure sensor Four functions in one probe: Measure-
Order no. 0563 4800 • Highly accurate position-independ- ment of flow, temperature, humidity and
ent sensor (± 0.3 Pa ± 1 %) absolute pressure
Highly accurate humidity/temperature • For monitoring filters and clean- • With robust, non-rotatable telescope (can be
probe (Ø 12 mm, for testo 480) rooms extended to 1,100 mm)
Measure with extreme precision: with an EUR XXX.XX • Flow velocity measuring range: 0 to +20 m/s
accuracy of up to ±1 %RH Order no. 0563 4800 • Handle with practical
• For a safe climate in the cleanroom measurement button
• Long-term stable testo 521-3 – Differential pressure EUR XXX.XX
• High-quality digital humidity and temperature measuring instrument (up to 2.5 hPa) Order no. 0635 1543
probe
With ihigh accuracy of up to ± 0.5 Pa
Vane/temperature probe (Ø 100 mm,
• Ideal for differential pressure
EUR XXX.XX for testo 480)
measurements in cleanrooms, thanks
Order no. 0636 9743 Determine flow velocity and volume flow
to high accuracy and resolution
• Direct zeroing of the display values of at the ventilation outlet
Lux probe for measuring light intensity • Vane diameter:
pressure probes
(for testo 480) 100 mm
EUR XXX.XX
Assessment according to the V-lambda EUR XXX.XX
Order no. 0560 5213
curve: for all common lamps and light Order no. 0635 9343
sources
testo 512 – Differential pressure measuring
• Also for white and warm light LEDs (K < 5000) instrument for 0 to 20 hPa Replacement flow hood 915
• Measuring range from 0 to 100,000 Lux x 915 mm (for testo 420)
Ideal for differential pressure
measurement on filters EUR XXX.XX
EUR XXX.XX
• 8 pressure units to choose from: kPa, Order no. 0554 4203
Order no. 0635 0543
hPa, Pa, mm H2O, mmHg, psi, inch
H2O, inch Hg Replacement flow hood
testo 816-1 – Sound level meter
EUR XXX.XX 305 x 1220 mm (for testo 420)
Precise sound level measurement
Order no. 0560 5127 EUR XXX.XX
according to IEC 61672-1 Class 2 and
ANSI S1.4 type 2 Order no. 0554 4201
• Memory for up to 31,000 readings
Replacement flow hood
• Incl. analysis software
360 x 1220 mm (for testo 420)
EUR XXX.XX
EUR XXX.XX
Order no. 0554 4200
Order no. 0563 8170
Norm-compliant range of measuring instruments for ventilation and air conditioning
in cleanrooms. With the expertise of 60 years' research and development, we provide
highly specialized solutions.

4 Laminar flow cabinets 5 Monitoring of temperature,


and other applications humidity, pressure
Other VAC measuring
instruments
testo 435-4 – Multifunction measuring
instrument
EUR XXX.XX
Order no. 0563 4354

Hot wire probe (Ø 12 mm, for testo 435)


EUR XXX.XX
Order no. 0635 1535

Lux probe (for testo 435-4)

Vane/temperature probe testo Saveris Base – including GSM mod- EUR XXX.XX
(Ø 100 mm, for testo 480) ule for data loggers Order no. 0635 0545
Ideal and very precise for small flow The heart of the professional monitoring
velocities system testo Saveris testo 635-2 – Temperature and humidity
• Flow velocity measuring range: • Receives the measurement data measuring instrument
+0.1 to +15 m/s from up to 150 probes EUR XXX.XX
• Automatic alarm, e.g. by Order no. 0563 6352
EUR XXX.XX SMS
Order no. 0635 9343 EUR XXX.XX testo 645 – Humidity/temperature
Order no. 0572 0221 measuring instrument
Air flow velocity matrix with telescope EUR XXX.XX
For measuring air flow at large air supply testo Saveris H2 D – 2-channel Order no. 0560 6450
outlets with laminar flow temperature/humidity wireless probe,
with display testo 176 H1 – Temperature and humidity
• On extractor hoods, HEPA filters, laminar
External, permanently connected data logger
flow cabinets in cleanrooms etc.
capacitive humidity sensor
• For use with a differential EUR XXX.XX
pressure measuring • High accuracy, fast response time, high
Order no. 0572 1765
instrument long-term stability
• Large measurement data memory
testo 175 H1 – Temperature and humidity
EUR XXX.XX EUR XXX.XX
data logger
Order no. 0699 70771 Order no. 0572 6222
EUR XXX.XX
Order no. 0572 1754
Hot wire probe (Ø 10 mm, for testo 480) testo Saveris U1 – wireless probe with
current/voltage input
Highest precision at low flow velocities testo 608 – Thermohygrometer
up to 5 m/s Integration of other measurement param-
eters into the testo Saveris monitoring EUR XXX.XX
• Measuring range 0 to +20 m/s, tight-
system Order no. 0560 6081
ness-compensated
• Fast results thanks to integrated calculation • Integration of all measurement
of the volume flow transmitters with standardized
• With robust, non-rotatable telescope (can be current/voltage interfaces
extended to 1,100 mm) • Flexible wireless data transfer
Highly precise, according to the
EUR XXX.XX
EUR XXX.XX Order no. 0572 3210 requirements of cleanrooms
Order no. 0635 1048
testo Saveris CFR Software basic All measurements in cleanrooms place
testo DiSCmini – portable nanoparticle package with web access licence
for 1 to 5 users
the highest demands on the measuring
measuring instrument
Ideal for the measurement of nanoparti- EUR XXX.XX instrument and the precision of the
cles, especially in the semi-conductor Order no. 0572 0182 measurement. Testo offers you a
industry
• Measurement of particle size from testo 6383 – differential pressure trans- comprehensive product range of
10 to 700 nm mitter for cleanrooms measuring instruments, measurement
• Ideal for personal measurements For integration flush into the cleanroom
thanks to compact design wall hoods, probes and practice-tested
• Measurement principle based on • Very precise at the lowest accessories for all critical environmental
the static charging of particles pressures from 10 Pa
• Optional: humidity and tempera- parameters in your cleanroom.
EUR XXX.XX ture measurement Our precision measurement technology
Order no. testo DiSCMini EUR XXX.XX
Order no. 0555 6383 is delivered with calibration protocols,
and we provide calibration services you
can depend on.

7
Precision measurement technology for cleanrooms from Testo

Full service for your cleanroom


Services for secure ambient conditions

2981 xxxx/MRH/06.2017
Subject to change, including technical modifications, without notice.
All prices net plus shipping costs and VAT, valid from 01/01/2017.
Testo not only offers a comprehensive range of highly accurate measuring instruments. In addition, Testo Industrial Services
is a full-service supplier for all quality assurance measures in the field of cleanrooms. Whether training for your staff, the
complete management of the calibration of your measuring instruments or the qualification and re-qualification of your

Payment 30 days net, 14 days 2% discount.


cleanrooms: We support you in keeping your quality high, and exceeding all norms at all time.
That is pure Testo quality.

Services for your cleanroom qualification


• First qualification and re-qualification of cleanrooms and • Testing and qualification of laminar flow cabinets,
ventilation systems isolators and other clean air technology plants
• Conceptual planning and implementation of all qualifica- • Individual and GxP-compliant documentation packages
tion tests according to DIN EN ISO 14644 and VDI 2083 adapted to your needs
• Implementation of risk management for cleanroom areas • Microbiological monitoring
and ventilation systems according to ICH Q9

www.testo.com