ISPSoft

Corporate Culture Tool Bar

Variable
Workplace

ISP Ladder Edit Area

Output Window
ISP Ladder
ISP program is mainly composed by Variable and ISP ladder.

Local
Variable
Edit Area

ISP Ladder
Edit Area Global
Variable
Edit Area
Variable Table

• Global Variable
- Without “Class "column
- Each “Identifiers” of variable can be use in all POU
- Each variable should be assign an address
Variable Table

• Local Variable
- Program type POU
: Only has 【Var】selection in class column.
: All variable should be assign a Address

Program Type POU


Variable Table

• Local Variable
- Function Block type POU
: Can be classified as 【Var】【Var_Input】【Var_Output】
: Address Declaration  Can be assign by system itself

Function Block Type POU


Variable Table

• Variable Naming Rules


1.Variable name can be composed as :Letter、Number、Underline.
2. First character can be either letter or underline.
3. Two consecutive underline is not allowed such as: __Delta.
4. The latest character can’t be underline such as Delta_.
5. Variable name which is same with PLC devices is not allowed.
6. Big character or small character is no difference.
7. Maximum characters: 16 space size.
Variable Table

• Edit of Variable
- Add Variable (Put the mouse cursor in the variable table area)
1.Key in directly in the Variable Table. (Way 1)
2.Double clicks in the blank area of Variable Table (Way2)
3.Press “Space” key (Way3)

- Modify Variable
1.Double clicks directly in table which is needed to be modified.
Variable Table

• Edit of Variable
- Random Selection: Keep pressing Ctrl + Mouse click on variables.

- Consecutive Selection: Keep pressing Shift + Mouse click on variables.

- After selected, click mouse right button for sub-menu for additional edit.
Variable Table

• Edit of Variable
- Variable Table supports sub-menu for editing use.
- Undo
Mouse
- Redo Right
- Cut Click
- Copy
- Paste
- Delete
- Select All
Variable Table

• Edit of Variable
- Keep pressing Alt + ↑↓Key to move Variable to up/down in the table.
Variable Table

• Edit of Variable
-Import/Export function of Function Block and Local & Global Variables.

Mouse
Right
Click
ISP Ladder Tools

• Program Tool Bar


- Comment/ Enable/Disable Network.
ISP Ladder Tools

• Program Tool Bar


- Bookmark.
ISP Ladder Tools

• Program Tool Bar


- Network.
ISP Ladder Tools

• Program Tool Bar


- Tool Select/Contact/Coil/API&FB.
ISP Ladder Edit

• Ladder Edit Area


-Left hand side of command brick—Logic、Operation、Function Block
-Right hand side of command brick—Coil、API

Left hand side Right hand side

Command
Brick
ISP Ladder Edit

• Ladder Edit Area


-Supports copy and paste function for individual device or whole network
ISP Ladder Edit

• Ladder Edit Area


-Select individual device or block for Copy、Cut、Paste、Delete…etc.
-Method: Keep pressing Shift and click 2 nodes to form a block

To form a block
ISP Ladder Edit

• Ladder Edit Area


- AND type block

Method:
1. Mouse click on A node
2. Keep pressing Shift
3. Mouse click on B node
ISP Ladder Edit

• Ladder Edit Area


- OR type block

Method:
1. Mouse click on A node
2. Keep pressing Shift
3. Mouse click on B node
Communication
Communication

• ISP Communication Tool Bar


Communication

• Grammar check
- Two major grammar check functions:
- Check current POU will just check only one POU
- Compile will check all POU

Error message
Communication

• Program download
- Mark the check box will download the additional information into PLC
Communication

• Program upload
- Mark the check box will upload the additional information to PC
Communication

• Devices Monitoring
- When under online Mode, all devices are allowed to be monitored.

Mouse
Right
Click
Thanks