M266C

1. Safety Information * When carrying out measurements on TV or switching 2.1 FUNCTION AND RANGE SELECTOR
power circuits, always remember that there may be high A rotary switch is used to measurement Functions and
DIGITAL CLAMP MULTIMETER The meter is completely portable, LCD, 3 1/2 digit clamp
amplitude voltage pulses at test points which can Ranges. When the switch is set to OFF position, the
OPERATOR'S INSTRUCTION MANUAL meter with insulation test function ( with option 500V
insulation tester unit ). It has been designed according damage the meter. meter does not operate.
to IEC-1010 concerning electronic measuring * Never perform resistance measurements on live circuits. 2.2 TRANSFORMER JAWS
instruments with an overvoltage category( CATll 1000V * Always be careful when working with voltage above 60V Pick up the AC current flowing through the conductor.
CAT III 600V ) and pollution 2 and safety requirements for dc or 30V ac rms. Keep fingers behind the probe barriers Press the TRIGGER to open the transformer jaws. When
hand-held current clamps for electrical measurement and while measuring. the finger press on the TRIGGER is released, the jaws
test. Follow all safety and operating instructions to ensure * When the jaw opening and to the conductor under test, will close again.
WRONG CORRECT
that the meter is used safely and is kept in good operating your fingers must keep behind the barrier indicator . 2.3 DATA HOLD
condition. The barrier or tactile indicator shall warn the operator A push switch( Push ON,Push OFF. All ACA, ACV, DCV,
of the limit of safe access. HZ ranges with this feature )
FRONT PANEL
1.1 Preliminary * Never ground yourself when talking electrical
measurement ,do not touch exposed metal pipes , 2.4 INPUT JACKS
* When using this meter, the user must observe all normal This meter has three input jacks that are protected 1
1. TRANSFORMER
safety rules concerning: outlets, fixtures, etc., which might be at ground potential.
Keep your body isolated from ground by using dry against overload to the limits shown. JAWS
- Protection against the dangers of electronic current. During use connect the black test lead to COM jack and
- Protection of the meter against misuse. clothing, rubber shoes ,or any approved insulating 2. TRIGGER
material. connect red test lead to VΩ jack. The red test lead is 9
* Full compliance with safety standards can be depended on function selected. 3. DATA HOLD
guaranteed only if used with test leads supplied. If * components should not be connect the temperature SWITCH
measuring socket when making voltage measurement The EXT jack is used for accept insulation tester unit
necessary, they must be replaced with the same model EXT banana plugs,
3
4. ROTARY SWITCH
or same electronic ratings. Measuring leads must be in with test leads. HOLD

when measurement insulation resistance. 2 5. LCD DISPLAY


good condition. 1.3 Symbols 8
3. Operating Instruction 6. INPUT JACKS
1.2 During Use Important safety information .refer to the operating manual. 7. DROP - PROOF
4
* Never exceed the protection limit values indicated in Dangerous voltage may be present. WRIST STRAP
specifications for each range of measurement. Earth ground 1. Set the rotary switch at desired A~ range position.
* When the meter is linked to measurement circuit, do not 8. TEMPERATURE
Double insulation ( Protection class II ). Press the trigger to open the transformer jaws and 5
touch unused terminals. clamp onto one conductor only( Fig1 ), The MEASURING
* When the value scale to be measured is unknown transformer jaws pick up the AC current flowing SOCKET
through the conductor. 6
beforehand, set the range selector at the highest position. 9. BARRIER OR
* Before rotating the range selector to change function, 2. When only the figure “ 1 ”displayed,it indicates 7
overrange situation and the higher range has to TACTILE
disconnect test leads from the circuit under test.
be selected. INDICATOR

01 04 05
3.2 Insulation Test 3.4 Measuring Resistance 4.7 Temperature
1. Connect the black test lead to the COM jack and the red CAT II 1000V CAT III 600V Accuracy
( Option 500V insulation tester unit )
test lead to the VΩ jack. Range Resolution 0°C to 400°C 400°C to 750°C
1. Connect the insulation tester unit VΩ;COM;EXT three
2. Set the rotary switch at desired Ω position and connect (32°F to 752°F) (752°F to 1382°F)
banana plugs to the clamp meter VΩ;COM;EXT.
2. Set the rotary switch of clamp meter at 2000MΩ position. test leads across the resistor under measurement. 0°C to
NOTE: Input Impedance: >9MΩ on all ranges 1°C
3. Set the insulation tester unit range switch to the 750°C
1. If the resistance being measured exceeds the maximum Overload protection:600V peak or 600Vrms AC ±1.0% of rdg 3 digits ±2.0% to rdg 3 digit
2000MΩ position. on all ranges. 32°F to
4. Use the insulation tester unit of the test leads connect value of the range selected or the input is not connected, 1°F
Frequency Range: 50Hz to 500Hz 1382°F
its L;E input connect to being tested installation's. an overrange indication“ 1 ”will be displayed.
Response: Average, calibrated in rms of sine wave
( Test installation's must be power OFF.) 2. When checking in - circuit resistance, be sure the circuit 4.8 Frequency
5. Set the insulation tester power switch to the ON position. under test has all power removed and that all capacitors Range Resolution Accuracy
have been discharged fully. 2kHz 1Hz ±2.0%of rdg±5 digits
6. Depress the PUSH 500V push-push switch, the 500V
on red LED lamp will light. Clamp meter display reading 3.5 Testing Diode
is the insulation resistance value. If the reading is below
5. Accessories
1. Connect the black test lead to the COM jack and the red
19MΩ, change clamp meter and insulation tester unit to test lead to the VΩ jack. (The polarity of red lead is“ + ”) 5.1 Supplied with the multimeter
20MΩ range, can be increase the accuracy. 2. Set the rotary switch at position and connect red Test Leads HYTL- 266
7. If the insulation tester unit is not use, the power switch lead to the anode, black lead to the cathode of the diode Battery 9V NEDA 1604 or 6F22
must shift to power OFF position, and the test leads under testing. The meter will show the approx. forward Operating Manual HYS007037
must leave the E. L input connect. That can be voltage of the diode. If the lead connection is reversed,
increase battery life and prevent electrical shock hazard. only figure“ 1 ”displayed.
5.2 Optional accessory
“K”type thermocouple HYTP - 010
3.3 Measuring Voltage 3.6 Continuity Test INSULATION TESTER UNIT 261
1. Connect the black test lead to the COM jack and the 1. Connect the black test lead to the COM jack and the red
red test lead to the VΩ jack. test lead to the VΩ jack. 6. Battery replacement
2. Set the rotary switch at the desired V or V~range (The polarity of the red lead is positive“ + ”) If the sign“BAT”appears on the LCD display, it indicates
position and connect test leads across the source or 2. Set the rotary switch at position and connect test that battery should be replaced. Remove the battery cover
load under measurement. leads across two points of the circuit under testing. of case. Replace the exhausted battery with a new one.
The polarity of the red lead connection will be indicated If continuity exists (i.e., resistance less than about 50Ω),
along with the voltage value when making DC voltage
Warning
built -in buzzer will sound.
measurement. Before attempting to open the battery
3. When only the figure “ 1 ”is displayed,it indicates cover, be sure that test leads have been
overrange situation and the higher range has to Overload protection:250V DC OR 250Vrms AC on all ranges. disconnected from measurement
be selected. Open circuit voltage: 700mV circuits to avoid electric shock hazard.

06 R-00-05-0794