You are on page 1of 8

http://biz.lgservice.

com

Room Air Conditioner


SVC MANUAL(Exploded View)
MODEL : TS-C122YDA0

CAUTION
Before Servicing the unit, read the safety precautions in General SVC manual.
Only for authorized service personnel.
1. Specification
Models TS-C122YDA0
Cooling Capacity kW 3.52
(Min∼Rating∼Max) Btu/h 12,000
Heating Capacity kW -
(Min∼Rating∼Max) Btu/h -
Power Input Cooling/Heating W 1 150/-
Running Current Cooling/Heating A 5.4/-
Starting Current Cooling/Heating A 26/-
W /W 3.05
EER
Btu/h.W 10.43
COP W /W -
Power Supply Φ / V / Hz 1/220/60
Power Factor % 99.3
Indoor,Max ㎥/min(cfm) 8.83
Air Flow Rate
Outdoor,Max ㎥/min(cfm) 18
Moisture Removal l/h 1.46
Indoor,H/M/L dB(A)+1 41
Sound Level
Outdoor,Max dB(A)+1 51
Refrigerant & Charge(at 7.5m) g(oz) R22, 650(22.92)
Additional Refrigerant Charge g/m(oz/ft) 20(0.22)
Type Rotary(Non Tropical)
Model PH180X1C-3FTU2
Motor Type PSC
Compressor
Oil Type SUNISO 4GSI
Oil Charge cc 400 cc
O.L.P Name -
Type Cross Flow Fan
Fan(Indoor)
Motor Output W 46
Type Propeller
Fan(outdoor) Motor Type AC Induction
Motor Output W 89
*
Circuit Breaker A 29
Power Supply Cable No.*㎟ 3*1.0
Power and Transmission Cable No.*㎟+No.*㎟ -
Piping Liquid Side mm(in) 6.35(1/4)
Connections Gas Side mm(in) 12.7(1/2)
Drain Hose O.D , I.D mm(in) 21.5,16(0.85,0.63)
mm 902*322*200
Indoor(W *H*D)
inch 35.5*12.68*7.87
Dimension
770*540*2450
Outdoor(W *H*D)
inch 30.31*21.26*9.65
Indoor kg(lbs) 9(19.8)
Net W eight
Outdoor kg(lbs) 35(77.1)
o o
Cooling(Outdoor) C( F) 21 ∼ 43
Operation Range o o
Heating(Outdoor) C( F) -
Max. Piping Length m(ft) 13
Max. Elevation Difference m(ft) 7.5
Tool Code(Chassis) Indoor + Outdoor SY + UL
Temperature Control Thermistor
Plasma Filter ○
Prefilter(washable/anti-fungus) ○
Auto Clean -
CHAOS W ind(Auto W ind) ○
Steps, Fan/Cool/Heat 3/4/-
Airflow Direction Control(up&down) Auto
Airflow Direction Control(left&right) Manual
Remocon Type W ireless Simple
Setting Temperature Cooling 18 ∼ 30
Range Heating -
Functions Auto Operation (Micom Control) -
Auto Changeover (Micom Control) -
Self Diagnosis ○
Timer 7h, On/Off
Sleep Operation ○
Soft Dry Operation ○
Restart Delay(minute) 3
Deice Control(Defrost) ○
Hot Start -
Jet Cool ○
Low Ambient Operation -
Special Function -
Dry Contact -
Network Functions Network Solution(LGAP) -
PI485 -
Note:

Note: Some of functions are slightly different depending upon models.


O : Applied, - : No relation The specification may be subject to change without prior notice for purpose of
* For circuit breaker rating, please conform to local standards wherever necessary. improvement.

2 Room Air Conditioner


2. Piping Diagrams
Indoor Unit Outdoor Unit

Liquid Side Capillary Tube

2-Way Valve
Th2

Th1

Heat Heat
Exchanger Exchanger
(Evaporator) (Condenser)

Compressor
Gas Side

Accumulator
3-Way Valve
High Pressure S/W

Cooling

LOC. Description PCB Connector


Th1 Thermistor for indoor air temperature
CN-TH1
Th2 Thermistor for evaporating temperature

Service Manual 3
3. Wiring Diagrams
Indoor Unit

GN/YL
BR
BL

1(L)2(N) 3
GN/YL
BR
BL

3854A23009

CN-U/D CN-HVB CN-DISP2


FUSE
RY-COMP3 RY-COMP4

CN-N2

CN-N1

CN-MOTOR

4 Room Air Conditioner


Outdoor Unit

BLUE

CAPACITOR
RED H C F RED

R S BLUE BLUE

OVERLOAD
PROTECT
C

FAN

YELLOW
BROWN

BLUE

YELLOW/GREEN

TERMINAL BLOCK 1(L) 2(N)


BLUE
BROWN

THE UNIT INDOOR

OUTDOOR DIAGRAM WIRING


EBY36312302

Capacitor
Terminal Block

Service Manual 5
Exploded View

Exploded View
1. Indoor Unit
135316

135301

135314

11
152302

55
13
131410 W3300

359011

342800

354210

435301 147582-1

147582-2

147581-1

268711 346810
35211B
135516
354212

352150 263230
135311
249941
146811
264110
WOFZZ

267110 W6640

249951 W0CZZ
268711

6 Room Air Conditioner


Outdoor Unit
Models: TS-C122YDA0

237202 437211

435301
437212

554032
435511

349600

559010

W0CZZ
552111
546810 567502
554160

447910 552117
W6640 W6631
430400 148000

649950

550140 552203-1

552203-2

430410

Service Manual 7
P/NO : MFL37322726 DECEMBER, 2008