Safeunit™ order form
Safeunit™ type: Packing or single Seal Flush Type SFP
Type SFP
Type SFQ
Type SFD

Flow:
3 l/min (0,75 GPM)
8 l/min (2 GPM)
15 l/min (4 GPM)
Quench Seal Type SFQ

Pressure area:
10 bar (150 psi)
25 bar (360 psi)

Complete hose assembly:


Yes

Seal connections: Double Mechanical Seal Type SFD


NPT 1/8 1/4 3/8
R 1/2 Other

Documentation:
English
German
Swedish
Other

Mounting: Alarm:
Bracket Stand AC-1 (20-250 VAC/DC)
DC-1 (10-36 VDC)

Europe Latin America Middle East, Africa, Asia North America


Slough, UK São Paulo, Brazil Dubai, United Arab Emirates Morton Grove, Illinois USA
Tel: 44-1753-224000 Tel: 55-11-3371-2500 Tel: 971-4-3438940 1-800-SEALING
Fax: 44-1753-224224 Fax: 55-11-3371-2599 Fax: 971-4-3438970 Tel: 1-847-967-2400
Fax: 1-847-967-3915
For your nearest John Crane facility, please contact one of the locations above.
If the products featured will be used in a potentially dangerous and/or hazardous process, your John Crane representative should be consulted prior to their selection and use.
In the interest of continuous development, John Crane Companies reserve the right to alter designs and specifications without prior notice. It is dangerous to smoke while handling
products made from PTFE. Old and new PTFE products must not be incinerated.
©2003 John Crane Inc. Print 10/03 www.johncrane.com ISO 9001, ISO 14001, ISO/TS 16949, QS-9000 Certified. B-Safeunit/Eng
Safematic Safeunit™
Complete monitoring and control solution
for seals and seal water systems
Installing the Safeunit™ seal water system Adjusting the seal water flow and pressure
will ensure trouble free operation of process with Safeunit will create the best possible
machinery in all conditions and achieve the operating environment for seals and
maximum life cycle profit of your investment. maximize the runnability of the process.

Save Seal Water

2 drops/second = 14 m3 / year
Safeunit seal water system dramatically reduces For example, with the water price of US $0.50/m3,
water consumption by up to 80%. This means a the annual savings in a mill with 300 pumps is US
considerable drop in waste water load. $300,000 (flow reduction 4 l/min/pump).

Normal operation Flow increases and


pressure decreases

2.5 l/min 2.5 l/min 2 l/min 6 l/min

4 l/min

Changes in the pre-set system values for Safeunit system also detects seal water
flow and pressure will indicate any possible leakage in the process resulting in extra
problems in seals and system well in heating and evaporation costs or expensive
advance. For automatic control, alarm quality problems such as dilution.
sensors can be used.
User friendly, compact unit
• Controls and monitors seal water flow and pressure
• Predicts seal and packing failures
• Reduces and pre-determines maximum seal water consumption
• Can be cleaned with equipment running. Alarm will not go off with the new improved
push-clean button
• Simplifies pump setup and service
• Detects and locates seal water line problems
• Flow indicator and pressure gauge with memory pin
• Unique non-clog valves
• Available with optional electrical alarms and LCS-leakage control system

Inductive low-flow alarm sensor (optional)

Pressure gauge with memory pin

Flow rate Indicator

Flow memory pin indicator

NEW! Improved push-clean button

Flow regulating valve

Pressure regulating valve


(for double seal applications)

Max. temperature +75°C (175°F)


Max. pressure 25 bar (360 psi). All rights reserved.

You might also like