You are on page 1of 2

ASME Sec. V Art.

-2 IQI Selection

Nominal Penetrameter
Single – Wall Material Thickness Range Source Side Film Side
Hole
INCH MM Hole Type Wire Type Wire Type
Type
Up to 0.25, incl. Up to 6.35 12 5 10 4
Over 0.25 through .375 Over 6.35 through 9.5 15 6 12 5
Over 0.375 through 0.50 Over 9.5 through 12.7 17 7 15 6
Over 0.50 through 0.75 Over 12.7 through 19.05 20 8 17 7
Over 0.75 through 1.00 Over 19.05 through 25.4 25 9 20 8
Over 1.00 through 1.50 Over 25.4 through 38.0 30 10 25 9
Over 1.50 through 2.00 Over 38.0 through 50.8 35 11 30 10
Over 2.00 through 2.50 Over 50.8 through 63.5 40 12 35 11
Over 2.50 through 4.00 Over 63.5 through 101.6 50 13 40 12
Over 4.00 through 6.00 Over 101.6 through 152.4 60 14 50 13
Over 6.00 through 8.00 Over 152.4 through 203.2 80 16 60 14
Over 8.00 through 10.00 Over 203.2 through 254 100 17 80 16
Over 10.00 through 12.00 Over 254 through 304.8 120 18 100 17
Over 12.00 through 16.00 Over 304.8 through 406.4 160 20 120 18
Over 16.00 through 20.00 Over 406.4 through 508.5 200 21 160 20

You might also like