You are on page 1of 1

DOC: LUM_HEB_WIRE_CO-AXIAL CABLE

LUMINOUS CO-AXIAL CABLE SPECIFICATION


Length of coil : 90 meter Date: 12-05-2015, Rev-00

Copper Dielectric Shield Braid Aluminium wire Sheath Outer Surface


Sr. No. Item Min. Min. Mini. Nominal Min. Nominal Aluminium Nominal Min. Approx. Jelly Nominal Min. Approx.
Brightness Weight Dia. after
Conductor Dia. Copper Wt. Annealing Thickness Weight Dia. Foil dia. Thickness Weight Overall Flooded Thickness Weight Overall Colour Outer Surface Eccentricity Coiling Packing
of copper (Kg./Km.) Foil (mm.)
(mm.) (Kg./Km.) in % (mm.) (Kg./Km.) (mm.) (mm.) (mm.) (Kg./Km.) Dia. (mm.) (Kg./Km) (mm.) (Kg./Km.) Dia. (mm.)

As per Luminous As per Luminous As per Luminous As per Luminous As per Luminous
1 RG6 1.00 6.98 Bright 0.25 1.78 5.84 4.56 0.09 1.80 4.74 0.22 3.00 5.19 1.06 0.86 23.35 6.91 standard standard standard standard standard
(Golden sample) (Golden sample) (Golden sample) (Golden sample) (Golden sample)

Note: - Coaxial cable meets all requirements of Reference specification, which has to be mutually agreed between Luminous & wire OEM
A CONSTRUCTION PARAMETERS C ATTENUATION Max. at 20 °C
1 Inner Conductor Electrolytic grade 99.99 % pure annealed high conductivity solid bare copper Frequency (MHz) Attenuation (dB/100 m)
2 Inner Conductor Nominal Diameter (mm) 1.02 1 5 1.95
3 Conductor surface finish Smooth & Bright 2 55 5.2
4 Dielectric Foamed PE (Gas Injected) 3 83 6.2
5 Nominal Dia. (mm.) 4.57 4 187 9.15
6 Insulation surface finish Smooth w/o Bubble 5 211 9.5
7 First Bonded Aluminoium tape 6 250 10.5
Outer Conductor Al Braid (Aluminium Wire braid coverage being >60 % )
8 Second 7 300 11.5
(0.16 mm x 16 x 4 )
9 Nominal Coverage (%) 60 8 350 12.45
10 Flooding Compound Jelly (Non flowing Amorphous Polypropylene (APD)) 9 400 13.3
11 Jacket UV Protected PVC (Black) 10 450 14.35
12 Approx. outer Dia. (mm.) 7 11 500 14.95
13 Bending radius min. (mm.) 65 12 550 15.7
14 Outer surface finish Smooth w/o Bubble 13 600 16.45
15 Meter Marking Progressive sequential length marking on every meter 14 750 18.35
B ELECTRICAL PARAMETERS 15 865 19.95
1 Inner Conductor Max. Resistance at 20 °C 2.13 (Ohm/100 meter) 16 1000 21.45
2 Loop Resistance at 20 °C 2.78 (Ohm/100 meter) D Strucctural Return Loss (db/100 meter)
3 Nominal Capacitance 53 (PF/meter) Frequency (MHz) Attenuation (dB/100 m)
4 Nominal Impedance 75 (Ohm) 1 From 30 to 300 MHz > 28
5 Nominal Velocity Ratio (%) 85 2 From 300 to 550 MHz > 22

Prepared By: Approved By:


Sunil Kumar Vijay Prasad
AM. - Quality (HEB) DGM- Engg.(R&D -HEB)