Minimum reflux ratio 0.

93200204
Actual reflux ratio 1.11840245
Minimum number of stages 9.68982892
Number of actual stages 21.3068831
Feed stage 11.0571777
Number of actual stages above 10.0571777
Reboiler heating required 0.71861632 Gcal/hr
Condenser cooling required 0.50100653 Gcal/hr
Distillate temperature 34.9563031 C
Bottom temperature 74.5368162 C
Distillate to feed fraction 0.33906319
HETP

Minimum reflux ratio 5.8329886


Actual reflux ratio 9.44306012
Minimum number of stages 27.3627579
Number of actual stages 40
Feed stage 20.1382656
Number of actual stages above 19.1382656
Reboiler heating required 0.83134702 Gcal/hr
Condenser cooling required 1.1402876 Gcal/hr
Distillate temperature -27.814649 C
Bottom temperature -6.4477797 C
Distillate to feed fraction 0.503
Theoretical stages Reflux ratio N*RR
11 19.3419767 212.761744
12 12.0446699 144.536039
13 7.69475213 100.031778
14 6.1798495 86.517893
15 5.54532896 83.1799344
16 5.12053754 81.9286006
17 4.77354894 81.150332 N*RR
18 4.44402256 79.9924061
250
19 4.10223737 77.94251
20 3.86084402 77.2168804
200
21 3.73747439 78.4869622
22 3.66352075 80.5974565
150
23 3.61256598 83.0890175
24 3.57435371 85.784489
25 3.54415852 88.603963
100

50

0
10 12 14 16 18 20 22 24 26