A B C D SCHEDULE OF FOOTINGS

3.50 3.50
As1 As2
MARK "L" "W" "t"
(BOTTOM) (BOTTOM)
1 CF2
CF2
50mm x 100mm x 1.2mm thk.
C-PURLINS SPACED CF1 1200 1200 300 6-Ø16 6-Ø16
@ 600mm.O.C.
2.50
CF1
CF1
W/ 121" x 121" x 16
3
" CF2 1200 1200 300 6-Ø16 6-Ø16
THK. ∠ BAR CLEATS
2 100mm THK. SLAB
ON-FILLW/ 10 mm Ø
REBARS @400mm O.C.

5 SCHEDULE OF FOOTING
2.25

E.W ON SAND &


GRAVEL BEDDINGS.
CF1 CF1

3 CF2
S 1 SCALE NTS
2.25

CF1 CF1
CF1
L

4 CF2

0.75
SCHEDULE OF COLUMN
3.00

fc = 3,000 psi
0.35

H
CF1 CF1 CF1 fy = 40,000 psi
0.75

W
5

RAFTERS

RAFTERS

RAFTERS

RAFTERS

RAFTERS

RAFTERS

RAFTERS

RAFTERS

RAFTERS
RAFTERS
CF2
COLUMNS C.1
WF WF
0.35

T
GROUND
3.05

FLOOR LEVEL

0.75
WF TO ROOF LEVEL
0.75 0.75
L
6 MAIN LONG BARS
and TIES
8pcs-Ø12mm VERTICAL
BARS W / Ø10mm TIES
SPACED @ 0.10 M. O. C
(2 SETS).

100mm THK. SLAB


ON-FILLW/ 10 mm Ø
REBARS @400mm O.C.
E.W ON SAND & L
GRAVEL BEDDINGS.

0.75
7

H
0.75

W
0.35
3.50 3.65 4.85 1.72
2 ROOF FRAMING PLAN

T
17.50
S 1 SCALE 1:100MM

0.75
1. THE MAXIMUM COMPRESSIVE STRENGTH OF CONCRETE
0.75 0.75
AS FOLLOWS: L
WALL FOOTINGS, SLABS-ON-FILL fc' = 20.70 Mpa
1 FOUNDATION PLAN BEAMS, SLABS, STAIRS fc' = 20.70 Mpa
S 1 SCALE 1:100MM

2. THE MINIMUM YIELD STRENGTH OF REINFORCING BARS 150


SHALL BE AS FOLLOWS: LENGTH
CL 2-12mm dia continous
10mm dia @ .20m O.C
Fy = 230.00 Mpa FOR BARS 16mm Ø AND LARGER

300
Fy = 230.00 Mpa FOR BARS 12mm Ø AND SMALLER 2-12mm dia continous TOP BARS
2-12mm dia continous

300
3. THE ACTUAL SOIL BEARING PRESSURE SHALL NOT BE
LESS THAN 145 Kpa AND ALL FOOTING DEPTHS SHALL 2-12mm dia continous BOTTOM BARS *STIRRUPS TYPICAL TIES
150 5 FOUNDATION PLAN
S 1 SCALE NTS
BE CARRIED TO A DEPTH OF NOT LESS THAN 1.20 SPACING, 3@ 0.05 2 @ 0.10 2-12mm dia continous
2* 0.15, REST @ 0.20m
METERS FROM THE EXISTING NATURAL GRADE LINE.

300
2-12mm dia continous

LINTEL BEAM LINTEL BEAM 4. ALL STRUCTURAL STEEL AND ANCHOR BOLTS SHALL
CONFORM TO THE MINIMUM REQUIREMENT OF ASTM
SEE GENERAL CONSTRUCTION
A-36 AND ASTM A-307 RESPECTIVELY. NOTES TO VERIFY MASONRY 4" CHB WALL

WINDOW
6 TYPICAL BEAM DETAIL OUTLINE OF CHB
WALL FOR WF-1A
WALL REINFORCEMENT SEE GENERAL CONSTRUCTION
NOTES TO VERIFY MASONRY
WALL REINFORCEMENT
OPENING 5. ANY CONFLICT IN PLANS AND SPECIFICATIONS SHALL S 1 SCALE NTS
600
(TYP.) BE REFERED TO THE ARCHITECT AND/OR ENGINEER
DOOR FINISH FLOOR LINE DOWEL BARS TO MATCH
OPENING FOR FINAL REVIEW AND APPROVAL. 6"CHB WALL CHB WALL VER. BARS

VARIES
6. NO DOWNSPOUT SHALL BE ALLOWED TO BE EMBEDDED
IN STRUCTURAL CONCRETE UNLESS APPROVED BY THE
STRUCTURAL ENGINEER IN WRITING.

400
DOWEL BARS TO MATCH 300

CHB WALL VER. BARS

400
7. ALL MASONRY UNITS SHALL HAVE A MINIMUM COMPRESSIVE

1.46
2-Ø12mm (TYP.) 2-Ø10mm (TYP.)

0.50
STRENGTH OF 3.45 Mpa AND SHALL BE SOLIDLY FILLED 2-10mmØ LONG'L
BOTTOM BARS

0.50
WITH GROUT. WALLS SHALL BE REINFORCED WITH 12mm Ø
VERTICAL BARS SPACED @ 400mm O.C. AND 10mm Ø

1.25

1.00
3 DETAIL WALL HORIZONTAL BARS SPACED @ EVERY THREE LAYERS OF
CONCRETE MASONRY UNITS UNLESS OTHERWISE INDICATED. 12mmØ TRANSVERSE
12mmØ TRANSVERSE
BOTTOM BARS SPACED
2.00
2-10mmØ LONG'L
BOTTOM BARS

S 1 SCALE NTS 50mm thk COMPACTED @ 300mm O.C.


GRAVEL BEDDING W1 F1 BOTTOM BARS SPACED
@ 300mm O.C. W2 F2
50mm thk COMPACTED
GRAVEL BEDDING

4 GENERAL NOTES
S 1 SCALE NTS 7 TYPICAL WALL FOOTING TIE BEAM 7 TYPICAL WALL FOOTING DETAIL
S 1 SCALE NTS S 1 SCALE NTS

REPUBLIC ACT 545


This drawing as an instrument of Professional
Service, is the property of ARCHITECT whether this FOUNDATION PLAN
ROOF BEAM AND ROOF TRUSS
S-1
project is executed or not. This document shall not
be reproduced or copied in part or in whole nor be LEGEND & ABBREVIATIONS GENERAL NOTES
ONE STOREY BUGALOW used in repetition of and for other projects or in
TYPICAL DETAIL OF CONNECTIONS
buildings without the written consent and permission
of the ARCHITECT. All drawings must be return
when no longer in use.