Person in charge: *
Construction project:
Project number:
Position: Date: 1/28/2020
Eccentric load
e x = 0.0 mm
e y = 0.0 mm
Anchor plate:
x = 185 mm 2.174 0.438
y = 80 mm
lx1 = 32.5 mm
lx2 = 32.5 mm
ly1 = 40 mm
ly2 = 40 mm 5.61
Distance between anchors: z
sx1 = 120 mm
Edge distances: sx1
without influence y x
Thickness of anchor base: 2
h = 240 mm
1
h
lx 2
sx1
ly 1
ly 2 lx 1 x
y
Wedge Anchor BZ plus A4 M10 hef 60
Design method A, ETAG 001, Annex C + TR 055
Assessment ETA-99/0010: MKT BZ plus / BZ-IG
The anchorage is verified. Boundary
Tension loads Shear loads Interaction conditions:
[ kN, kNm ]
bN [%] bV [%] bN,V[%]
Static / quasi-static action 63.6 17.5 58.0 OK
The calculation only applies if the notes on the last page are observed.
Anchor loads
Anchor 1 2
NSd [kN] 5.12 5.12
Anchor loads
Anchor 1 2
VSd [kN] 2.81 2.81
Vx,Sd [kN] 0.00 0.00
Vy,Sd [kN] 2.81 2.81
Installation parameters
Thread M = 10 mm
Diameter of drill hole d0 = 10 mm
Depth of drill hole h0(1) = 75 mm
Effective anchorage depth hef = 60 mm
Installation torque Tinst = 35 Nm
Width across nut SW = 17 mm
Minimum thickness of anchor base hmin = 120 mm
Diameter of clearance hole
in the fixture df ≤ 12 mm
Remarks
The anchors are without influence of edge distance, if: c ≥ max ( 10 hef ; 60 d )
If the diameter df of the clearance hole does not correspond with the specifications in [1], Table 6.1,
or with the design of slotted holes, follow the notes in [1], chapter 1.1.
The calculation regards data for standard thickness of concrete slab.
The design is based on the assumption that the anchor plate remains flat under the acting
forces.
The proof of the capacity of the anchor base component shall be shown according to chapter 7 in [1].