Product Data Sheet

Edition No. 01 (October 2015)


SikaGrout -215

SikaGrout -215
Pumpable Shrinkage Compensated Cementitious Grout
Construction

Description SikaGrout-215 is a shrinkage compensated self levelling, cementitious grouting


mortar with extended working time to suit local temperature.

Uses SikaGrout-215 is suitable for repairs to concrete structures and the following
grouting works with clearance of 10mm or more:
n Machine foundations
n Rail beds
n Columns in Precast construction
n Concrete anchors
n Bridge bearings
n Cavities
n Gaps
n Recesses
Characteristics / n Highly early strength
Advantages n High ultimate strength
n Extended working time
n Dense, non-shrink
n Non-toxic, non-corrosive
n Chloride and iron-free
n High final strength
Instruction for Use
Surface Preparation Surface Preparation
Concrete surfaces should be clean, sound and free from oil, grease, cement
laitance and all loosely adhering particles. Metal surfaces (iron and steel) should
be free from scale, rust, oil and grease. Absorbent substrates must be saturated
thoroughly, but there should be no standing water.
Mixing
The pre-mixed powder is added to water to suit the desired consistency. For
flowable consistency, approximately 4.2 litres of water per bag is required. Mix
mechanically for 2-3 mins with a slow speed drill (max. 500 RPM) until a smooth
even consistency is achieved.
Application
After mixing, allow the mortar to rest for a while, stirring lightly to ensure that air
displayed by the grouting is allowed to escape. When carrying out base plate
grouting, ensure that sufficient pressure head is maintained to keep mortar flow
uninterrupted. Make sure that the necessary formwork is firmly in place and kept
water light. SikaGrout-215 may be placed in thickness up to a maximum of 50mm
at one pour.Where large areas are to be placed, it is important to maintain a
continuous flow throughout. It is necessary to organize the work sequence
properly (manpower, materials, etc.) to ensure an uninterrupted flow. In such large
areas, SikaGrout- 215 may also be pumped. A heavy duty diaphragm pump is
recommended for this purpose. Screw feed and piston pumps may also be used.
Specific Application
Grouting under base plate: Use flowable consistency
Grouting Anchor bolts: Use trowellable consistency
Grouting large volumes: For sections thicker than 50mm it is necessary to fill the
SikaGrout-215 with graded 10mm sil silt-free aggregate to minimize temperature
rise. The quantity of aggregate should not exceed 1-part SikaGrout-215 by
weight. For such mixes, a conventional concrete mixer and pump may be used.
Cleaning
Clean all tools and equipment with water immediately after use. Hardened mortar
can only be mechanically removed.

SikaGrout -215 1/2


Important Use SikaGrout-215 for repairs to concrete structure and grouting only.
Recommendations Minimum Gap: 10mm
Maximum Gap: 50mm
Minimum Application Temperature: 10 0C
At temperature lower than 20 0C setting time and strength gain will be slower.
Cure exposed mortar surface for at least 3 days with Anitsol curing compound
or use other approved curing methods.
Coverage/Consumption SikaGrout 1.84 kg 25 kg 74 x 25 kg bag
(approx.) Water (Litre) 0.31 4.2 309
Volume Mortar 1 lit. 13.6 lit. 1 m3
Performance Flow (British Standard Cone):
280 - 320 mm after 3 minutes
260 - 300 mm after 30 minutes
Construction

(Keep on stirring slightly)


Comprehensive Strength in MPa (N/mm2):
(Water content: 4.2 liters/25 kg bag. Testing & storge at 25 0 C under water)
1 day 38
3 days 45
7 days 55
28 days 70
Technical Data

Form Powder

Color Grey

Bulk Density 1.64 kg/l

Wet Density 2.10 - 2.20 kg/l


Storage Condition Store in a dry place
Shelf Life 12 months when unopened
The information, and, in particular, the recommendations relating to the
Legal Notice application and end-use of Sika products, are given in good faith based on Sika’s
current knowledge and experience of the products when properly stored, handled
and applied under normal conditions in accordance with Sika’s recommendations.
In practice, the differences in materials, substrates and actual site conditions are
such that no warranty in respect of merchantability or of fitness for a particular
purpose, nor any liability arising out of any legal relationship whatsoever, can be
inferred either from this information, or from any written recommendations, or from
any other advice offered. The user of the product must test the product’s
suitability for the intended application and purpose. Sika reserves the right to
change the properties of its products. The proprietary rights of third parties must
be observed. All orders are accepted subject to our current terms of sale and
delivery. Users must always refer to the most recent issue of the local Product
Data Sheet for the product concerned, copies of which will be supplied on
request.

Sika Philippines, Inc.


888 Unit A & B,
Marcos Alvarez Ave., Talon V, Tel. No.: +(632) 806-2875
Las Piñas City 1747 Fax No.: +(632) 806-2883
Philippines Website: phl.sika.com