You are on page 1of 3

Document- CGHY QF 5086 Format for Reporting Test Result

TEST RESULTS
CODE NO: 2018/11/6254-2018/11/6256 Test started on-03/12/2018
DATE:09.12.2018 Test completed on- 09.01.2019
Sl. Name of the Performed as Specified Requirements Result Obtained
No Test per Standard/
Clause
2018/11/ 2018/11/ 2018/11/
6254 6255 6256
1 Minimum Cl 4 of IS:7834 Shall not be less than 3 mm 3.01 mm 3.04 mm 3.12 mm
Thickness (P-1)
2 Socket Length, L 5,5.1,5.1.1 ,5.1.2 & 50 mm 63 mm 90 mm
Table-1 of IS:7834 Tee 900 Tee 900 Tee 900
(P-1) & 2.2.3 of IS:7834 31mm 38 mm(Min) 51mm 31.71 (Min) 38.08 (Min) 52.10 (Min)
(P-4) (Min) (Min)
3 Mean Inside 50.1mm 63.1mm 90.1mm 50.10mm 63.20 mm 90.20mm
Diameter at mid- (Min) (Min) (Min) (Min) (Min) (Min)
point of Socket 50.3 63.3mm 90.3 50.30mm 63.30 mm 90.30mm
Length (Max) (Max) mm(Max) (Max) (Max) (Max)
4 Angle of the taper Page: 1 Note:1 of Shall not Shall not Shall not 00 40 00 40 0030
IS:7834 exceed 0 exceed 0 exceed 0 minutes minutes minutes
(P-1) degree degree 40 degree 30
40 minutes minutes.
minutes.
5 Out-of-Roundness Cl 5.1.3 of IS:7834 Shall be Shall be Shall be 0.08 mm 0.10 0.10
tolerances of (P-1) within within within
Socket Inside 0.007D 0.007D i.e, 0.007D i.e,
Diameter i.e, Maxm 0.441 Maxm 0.63
Maxm 0.3 mm mm
5mm
6 Laying Length Cl 2.2.2, Table-1 & fig 1 26 +2.5 32.5 +3.2 46 +5 27.20 mm 33.60 mm 45.98 mm
of IS:7834(P-4) -1mm 1mm 1mm (Min) (Min) (Min)
27.34 mm 34.40 mm 46.90 mm
(Max) (Max) (Max)
7 Stress Relief Test Cl 6 ,6.1 & 6.1.1 of When tested by the method described Confirms Confirms Confirms
IS:7834 in Appendix A, none of the test
(P-1) specimens shall show blisters,
excessive delamination or cracking or
signs of weldline splitting.
8 Opacity Cl 6.2 of IS:7834 0.0 % 0.0 % 0.0%
The wall of the fitting shall not transmit
(P-1)
more than 0.2 percent of the visible
light falling on it.
9 Effect on Water 0.001 0.002 0.002
First Extraction Cl 6.3 of IS:7834
Lead (P-1) 0.1 ppm (Max.)
Third Extraction 0.3 ppm (Max.) Not Not Not
Lead Detected Detected Detected

Dialkyl Tin C4 & 0.02ppm (Max.) Not Not Not


higher homologues Detected Detected Detected
measured as Tin
Other toxic 0.01ppm (Max.) Not Not Not
substance Detected Detected Detected

Remarks:Nil

Signature Signature
(Of Individual Performing the Test) (Technical Manager)
Document- CGHY QF 5086 Format for Reporting Test Result
TEST RESULTS
CODE NO: 2018/11/6254-2018/11/6257 Test started on-03.12.2018
DATE: Test completed on-09.01.2019

Sl. Name of the Performed as Specified Requirements Result Obtained


No Test per Standard/
Clause
2018/11/ 2018/11/ 2018/11/
6254 6255 6256
10 Short Term Cl-6.4 of IS:7834 When tested in accordance with Passes the Passes the Passes the
Hydraulic Test (P-1) Appendix D, the fittings test test test
shall withstand the
minimum pressure of 4.2 (+0.2, -0)
times of working pressure of the fitting
for 1 h without failure.
(Pressure = 4.2 x10 Kgf/cm2 For Class
-5 &
Pressure = 4.2 x 6 Kgf/cm2 For Class
-3)

11 K-value IS:4669 -- Fore Code: 2018/11/6257

57.47

Remarks:Nil

Signature Signature
(Of Individual Performing the Test) (Technical Manager)
Document- CGHY QF 5086 Format for Reporting Test Result
TEST RESULTS
CODE NO: 2019/02/6337 Test started on- 20/02/2019

DATE: 05.03.2019 Test completed on- 05.03.2019

Sl. Name of the Test Performed as Specified Result Obtained


No per Standard/ Requirements
Clause

1 Effect on Water 0.014 ppm


First Extraction Cl 6.3 of IS: 7834
Lead (P-1) 0.1 ppm (Max.)

Third Extraction 0.3 ppm (Max.) 0.008 ppm


Lead
Dialkyl Tin C4 & higher 0.02ppm (Max.) Not Detected
homologues measured as Tin
Other toxic substance 0.01ppm (Max.) Not Detected

Remarks: Nil

Signature Signature
(Of Individual Performing the Test) (Technical Manager)