You are on page 1of 1

WELDING CONSUMABLE CONTROL LOG SHEET

Baking Time Material


Electrode Electrode Electrode Baking Holding
Date Qty Start End Controller
Brand/ SFA Batch No Size (mm) Temperature Temperature
Name/Sign
Maruthi
23.07.14 180425 40 No’s Dia.3.15 8:00AM 10:00AM 250 Deg.C 100 Deg.C
E7018
Maruthi
24.07.14 165425 40 No’s Dia 2.5 8:00AM 10:00AM 250 Deg.C 100 Deg.C
E309

Key person Responsible for Electrode Baking and Holding is Mr._____________________________

Electrodes of one Batch No. is stacked and bundled by metal wire with a tag of batch No. on the Bundle.

SS & CS welding electrodes are Baked separately.

Electrode returned by the welder at the end of the shift is suitably identified by white color and sent for 2nd baking operation.

If White color marked electrodes are returned by the welder at the end of the shift is identified by yellow color and sent for 3rd baking
operation. After 3rd baking electrodes should be suitably discarded.

Electrodes are issued to welders only in Portable ovens/ Quivers.