TDS Down report

26/08/2009
7:00am to 8:30am
 I reported from drilling crew that there is a spark on TDS service loop cable.
 Direct I go and isolate the TDS after this go to check the problem.
 The problem that I found one phase of the main service loop power cable touch
the small ground cable and touch the clamp on the mast (which hang the power
service loop) and small part of this phase insulation is damaged and make short
circuit may be this happen because of vibration and rain.
 After this I clean the place of sort circuit good and found cable in good condition
so I isolate it good by plastic tape and rubber tape and scotch spray and keep the
cable away from the clamp and ground cable.
 Make function test for TDS and working good now.