You are on page 1of 1

FLO-TITE PMI TESTING FOR DM310

ChemLite Serial Number Sample Material Number Al Cu Fe Si Cr Mn Ni Ti V Mo Nb Co Al Co Cr Cu Fe Mn Mo Nb Ni Si Ti V V Std.


Name ID of Confidenc Dev.
Analyses e
Date/Time
11/26/2018 10:06 4235 42351532005 2" SS-316 1 88.90% <0.1 0.25 64.7 0.6 16.6 0.51 12.6 <0.05 <0.1 4.67 <1.0 <1.0 <0.1 <1.0 16.6 0.25 64.7 0.51 4.67 <1.0 12.6 0.6 <0.05 <0.1 0
11/26/2018 10:07 4235 42351532005 1-1/2" SS-316 1 89.30% <0.1 0.25 65.2 0.6 16.6 0.6 12.6 <0.05 <0.1 4.24 <1.0 <1.0 <0.1 <1.0 16.6 0.25 65.2 0.6 4.24 <1.0 12.6 0.6 <0.05 <0.1 0
11/26/2018 10:23 4235 42351532005 1" SS-316 1 98.70% <0.1 0.25 65.2 0.6 17 0.66 13 <0.05 <0.1 3.25 <1.0 <1.0 <0.1 <1.0 17 0.25 65.2 0.66 3.25 <1.0 13 0.6 <0.05 <0.1 0
11/26/2018 10:24 4235 42351532005 Ball SS-316 1 98.00% <0.1 0.25 67.1 0.6 16.9 1.22 10.6 <0.05 <0.1 3.32 <1.0 <1.0 <0.1 <1.0 16.9 0.25 67.1 1.22 3.32 <1.0 10.6 0.6 <0.05 <0.1 0