You are on page 1of 7
SSji_ SENSORS INDIA 2151/10. 7-5, NEW PATEL Sagan NEW BFL 110 098 (nse) PHONE earache PEL spans ease mai: saleseisensarsindia.com wowewsensorsindiacom SIA/S.1/084/2014-15 DATED: 23/06/2014 M/s. SHILPI CABLE TECHNOLOGIES LIMITED A 19/B ~ 1, EXTENTION M.C.LE MATHURA ROAD, P.O. BADARPUR NEW DELHI ~ 110044 PH. NO.: 011 - 43227900 KIND ATTN: Mr. MUKESH KUMAR GUPTA (HEAD. REGARDING: TESTING EQUIPMENT UALITY & R&D) Dear Sir, ‘Thanks for your valuable enquiry on 21 june 2014, We are quoting hereunder for the same. LOW TEMPERATURE WINDING CHAMBER SIZE: 600 mm (W) x 600 mm (D) x 900 mm (H) (Approx.) Temperature Range: Ambient to (-) 40°C Temperature Accuracy: £1°C Control System: ‘PID’ controller Compressor: Cascade System The chamber also consist a winding arrangement. It is PLC based system to undertake the cooling cycle, winding, motor speed, no. of turns which are desired for different cross sectional of wire. EXTERIOR The chambers are designed to occupy minimal area and to fit on to most standard benches. The outer case is corrosion resistant made of mild steel, precision cut and punched, finished in Grey color textured stove enamel or powder coating with control panel in a contrasting color. INTERIOR The interior is TIG weided bright annealed Stainless Steel grade 304, fitted with U section runners to accommodate non - tripping shelves of stainless steel Grid. The door is retained by quick release easy to use fasteners, and closes onto silicon rubber gasket, TIG welded INSULATION ‘The space between the inner chamber and the outer chamber approx. 125 mm GLASS WOOL PADS / PUF pads will be used, Gi SeNsoRs toa PISI/I0, 1-5, NEW PATEL NAGAR, ‘MEW OFLIt-110 008 (india) PHONE. -s911125701446 4o1112s7046s5 TEL/FAX & 4911125701147 Email: saleseasensorsindia.com ‘www,.sensorsindia.com SW/S.1/084/2014-15 DATED: 23/06/2014 MOUNTING Lockable pedestal grip proof Nylon/Polymer Wheel will be provided to make mobile chamber. poor Approximately 125 mm thick with inner and outer made of stainless steel supported on heavy duty custom built hinges AIB CIRCULATION Minimum temperature differential is maintained by powerful centrifugal fans fitted behind a baffle plate in the liner, ensuring an even and constant circulation of air throughout the chamber and its load. The fan motors are well rated and mounted externally with additional ‘motor. RUN = UP - TIME Ambient to (-) 40% ELECTRICALS All electrical will be best make such as Siemens, L & T, ERI, TC, EE or any equivalent. CONTROL SYSTEM ) PID Controller. Geared Mechanism Drive Fixture Sensors etc, Price £.1,60,000/00 ihr. 2 , 6,50,000/00 BUND SENSORS INDIA 2151/10, 75, NEW PATEL Nasa, ‘ME GiLs-140 908 (nda) PHONE: FO1LI25701340 $9112957046 TEL/EAR s 49111257018 email: salestisensorsindia ‘yevnw.sensorsindia.com SWN/S.1/084/2014-15 DATED: 23/06/2014 Cold impact test arrangement as per fig.5, ISO ~ 6722. The cold impact test perform the Impact in the middle of the test sample. All mechanical parts are S.S made for rust free operation Price %.85,000/00 UV RADIATION APPARATUS FOR CABLES AS PER ASTM G 154 This is a device for exposing materials to alternate cycle of florescent ultra-violet light & condensation, It will have light source eight FS ~ 40 fluorescent Sun Lamps. These Lamps will be e mounted in two banks of four each, are rich in Ultra-Violet energy between 280 ~ 350 watts at an operating voltage of 220 volts. An electrical discharge within the tube generates ultra ~ violet energy at 254 nano-meters which will excites the phosphor coating causing it to fluoresce & will radiate approx. 85%of the lamp’s energy between 280- 350 Nano meters. The condensation will be produced by heating water in a stainless steel sump of the unit with a electric immersion heater. Natural convection will cause saturate air to move up across the face of the exposed panels. Rack panels will act as exterior walls of the test chamber Ambient room air moving across the backs of the test panels will cause a temperature differential and dew droplets condense on the panel face. The condensation cycle will allow water to form naturally free of mechanical & thermal shock with maximum purity. ‘The apparatus will have two specimen racks, 330 mm high & 1154 mm wide, each facing one bank of lights and will accommodate a total of 20 rack panels, approximately 100 mm C 300 mm. Controls: The system is logic controller based. A program timer will automatically contro! the UV & condensation cycles of the UVCON & programming. Each cycle will program by typically 24 hours of UV followed by four hours of condensation Temperature will be measured & controlled by a solid state circuit NEW BELIB 120 908 fc PHONE: 911125703186 sonisas70%6s6 TeLipA nasa 7 Email: salesisensersinde.com veuw.censorsindig.com SY/I/5.1/084/2014-15 DATED: 23/06/2014 The temperature will be set on dispiay & monitored by readout Digital Pane! Meter on the Control Panel. The apparatus will normally operate between 50 & 70 +3°C during the Ultra ~ violet exposure & between 40 & 50 43°C during condensation exposure. Price &, 6,50,000/00 AGEING OVEN. (6 SHELL) INNER SIZE of the chamber: 100 mm (Dia.j X 400 mm (6 Shell) (length) TEMPERATURE RANGE: 200°C ACCURACY: £1°C TEMPERATURE RESOLUTION: - 0.1°C CONTROL ACCURACY: - 1% OF OVER ALL RANGE. CONSTRUCTI The system is a controller based. Ageing oven will be constructed in such a way that it will house independently controlled tubes of 100 mm. dia. having 400 mm Length (6 Nos.) with individual air source for 7 ~ 20 air changes per hour. The chamber has switch to switch off, when not in use. Outer chamber will be made of thick gauge CRC mild steet sheet with nice fabrication and extremely attractive finish in Siemens Grey powder coated. The tubular chamber will be constructed of rugged material for longevity and durability The sample hanging arrangement (Hooks) will be fitted at the back of the top lid of the shell having minimum 20 mm distances from the other hook. (1) Hooks at the back of the lid will be fixed) or as per your requirement. Especially Developed Jacket Heater will be fitted on the outer core of the tubular chamber for uniform heating, A composite digital control temperature to control independent cell temperature. Electrically operated air sources will be part of each chamber for achieving 7 ~ 20 air changes per hour. (Air - Source.) (6 Nos.) for monitoring the air changes as per the requirement specially developed flow meter will be part of each control ‘Six Shell Ageing Oven Price £. 4,25,000/00 SENSORS INDIA 2181/10, 74, NEAY PATEL NAGAR, Tew Get Ht-210 008 sao) PHONE seyv]2s701b45 $97 1125004655, TELL FAX he 4911195701197 Email: salesaisensorsingka.com wwwasensorsindia.com SWS. 1/084/2014-15 DATED: 23/06/2014 WATER BATH Size: 600 mm (W) X 600 mm (D) X 1200 mm (L) (inside Stainless Stee!) Temperature Range: (-+) 25°C to (+) 65°C. Temperature Accuracy: 1% Temperature Uniformity: +1°C. Temperature Resolution: 0.1°C Power: Mains operated 230V AC/SO Hz. Timer: Time hour meter will be provided indicator: Mains ON/OFF indicator, fault indicator etc. Digital temperature Indicator with Sensor. Seating: Thermo statically seated with glass wool to without temperature losses. (doubie walled) Cover: Cover will be fitted in working condition, Stirrer: Stirrer will be fitted with the item Heating Load: 4 KW This chamber wili be double walled type inner wall will be made of stainless steel and outer wall will be made of mild steei with powder coated paint or stove enameled, A lid is also provided to cover the bath. A digital temperature indicator cum controller is provided to control the temperature. A glass thermometer is also provided With Digital Control system. HEATING OVEN Size: 600mm X 600mm X 600mm (Approx.) Range: Ambient to 200°C Temp. Accuracy: 1% Temp. Resolution: +1°C. Heating Load: 5 KW (Approx) Voltage: 230 Volts AC Contro! System: PID controller Price &. 1,.24,000/00 SENSORS INDIA Near Vat Us 110 908 i s9L432s 791655 TELPRAYS 189s" Limail: saleswscnsorsii.com ‘wuwuscensorsindis.com SUWS.1/084/2014-15 DATED: 23/06/2034 Scrap abrasion test is designed as per the 1S0:6722. The System is completely automated controtier based. Diameter of needie: 0.45mm+0.01mm ‘Type of needle: Spring wire Frequency: 55:5 cycles/min Adjustable Displacement of the needie: 201mm Length of abrasion: 15.5::1mm : Mass: The vertical force on the test sample shall be constant under dynamic conditions Price %.1,85,000/00 SWS.1/084/2014-15 Gfi_ Sensors ior 2154/40, 1-5, NEW” PATEL NAGAR ‘NEW GELI-130 O08 Cn PHONE: «011825701146 S 491LS?0H6S TEL/PAXG 4OULL35?000 rial: salesdisensorsindia.comt DATED: 23/06/2014 bj ©) 0) e) oy 9) hy ) id ) » n) 3) °) a Prices Packing & Forwarding Insurance: Payment Sales Tax Delivery Excise Duty Warranty. Validity Dispatch Specification: Cancellation: Instaliation: Calioration, Inspection: Jurisdiction Cancellation TERMS & CONDITIONS Prices are exworks, Delhi. Freight, Bank charges, octroi & other incidental expenses shalt bbe extra at actuals to your account @ 3% oxtra (Nil at Delhi) 2% extra, (Nil at Delhi) 50% advance along with order, balance payment against Performa Invoice prior fo dispaten, LST. @ 12.5% of C.S.T. @ 2% against form'C’ otherwise C.S.T @ 12.5% or as per VAT oF as applicable al the time of delivery. ‘C’ form must be sent prior {0 dispatch, (If'C’ form is not being sent with P.O, or Performa Invoice, a security deposit of 10.5% towards the difference in VAT will be added to the balance payment, which will be refunded on receipt of “C' form within the stipulated period.) 6 ~ 8 weeks aller we receive a technically and commercially clear order Extra as applicable at the time of delivery At present, NIL All equipments are warranted against manufacturing defects & workmanship for ONE YEAR from the date of delivery within normel operating conditions, as specified for the particular equipment. 20 days from date & subject to confirmation in writing thereafter. For outstation dispatches, mode of dispatch to be intimated and road permit, it any, fo be provided along with the purchase-order. For local delivery within Delhi, material will have to be collected from our works, ‘Specifications are subject to revision without prior notice for the custom built equipment Orders are not subject to cancellation. Advance if any will be forfeited without prejudice. If required, first-class (o & fro travel fare & lodging / boarding wall be borne by the custorner 1 Patty. Where applicable, Calibration certificate from recognized test Laboratory can be provided, Calibration charges will be extra as prevailing at the time of calibration. Time required for calibration will depend on concemed laboratory & the equipment / instrument to be calibrated Please confirm in writing before placing order Equipment may be inspected at our works before dispatch, with prior appointment. All disputes shall be subject to Delhi Jurisdiction only. All our offers are subject fo ‘Force Majuro’ clause. ‘Any order placed on us cannot be caneslied and incase cancelled the amount paid in ‘Advance will forfeit For SENSORS INDIA ALK DUBE

You might also like