General Building Structure Type √ Frame Structure Number of storeys applied for permit (in Nos.) 3.5 +B Number of storeys considered in structural design (in Nos.) 3.5 +B Number of storeys considered in the design provision for Yes further extension √ No Total height (h) of structure with extension(in m) 11.375 NBC 101-1994 MATERIALS SPECIFICATIONS Structural Aluminium Brick Masonry Materials to be used in structure(tick the listed materials that Timber will be used in structure element) Structural Steel √ RCC(Reinforcement Bar) Stone Masonry NBC 102-1994 Unit Weight of Materials Specify the design unit weight of materials: Steel (in KN/m3) 78.50 Specify the design unit weight of materials: RCC (in KN/m3) 25.00 Specify the design unit weight of materials: Brick Masonry (in kg/m3) 19.20 NBC 103-1994 Occupancy Load (Imposed Load) For Residential buildings Occupancy Load (Uniformly Distributed load in kN/m2) for Rental Rooms 2.0
Occupancy Load (Uniformly Distributed load in kN/m2 ) for
Corridors, Staircase, Store 3.0
Occupancy Load (Uniformly Distributed load in kN/m2 ) for
Balcony 3.0 NBC 104-1994 Wind load Wind Zone Basic wind speed (in m/s) NBC 105-1994 Seismic Design of Buildings in Nepal √ Seismic Coefficient Approach Method adopted for earthquake resistant design Response Spectrum Method Others Adopted Code for Seismic Design √ IS 1893 Type I (Hard) Subsoil category Type II (Medium) √ Type III (Soft)
Seismic Weight (W) (in kN) 2944.856
Fundamental Time Period of the building along X (Tx) (in Seconds) 0.464 Fundamental Time Period of the building along Y(Ty) (in Seconds) 0.464 Seismic zoning factor (Z) 0.36 Importance Factor (I) 1.00 Response reduction factor (R) 5 Spectral acceleration coefficient (Sa/g) along X 2.5 Spectral acceleration coefficient (Sa/g) along Y 2.5 Design Horizontal Seismic Coefficient Along X (Ah) 0.09 Design Horizontal Seismic Coefficient Along Y (Ah) 0.09 Base Shear(VB) for Seismic Coefficient Along X 265.030 Base Shear(VB) for Seismic Coefficient Along Y 265.030 Maximum Inter-storey Drift 0.00541 Corresponding Storey height for Maximum Inter Storey Drift (h) 2845 mm
Maximum Inter-Storey Drift Ratio 0.00190
NBC 106-1994 Snow Load Perennial Snowfall type or condition Occasional √ No snowfall Elevation of construction site (in m) Design Depth of snow (in cm) Design Density of snow (in g/cm3) NBC 107-1994 Provisional Recommendation on Fire Safety √ Yes Have you considered fire safety requirement? No NBC 108-1994 Site Consideration for Seismic Hazards Whether Distance of construction site from toe/beginning of Yes downward slope is within 50m? √ No Whether Distance of construction site from river bank is within Yes 50m? √ No Yes Availability of soil test report √ No NBC 114-1994 Construction Safety Are you sure that all safety measures will be fulfilled in the √ Yes construction site as per this code? √ No √ Safety hard hat √ Safety goggles Safety wares used √ Safety boots √ Safety belts √ First aid facility Structural Data for Framed RCC Structure NBC 110-1994 Plain and Reinforced Concrete √ M20 M25 Concrete grade in structure M30 M35 Fe-415 Reinforcement Steel Grade √ Fe-500 Fe-550 Slab design 4 side continuous 1 short side discontinuous √ 1 long side discontinuous 2 adjacent side discontinuous Boundary condition of slab 2 long side continuous 2 short side continuous 1 long side continuous 1 short side continuous 4 side continuous Effective Thickness of slab (d) (in mm) 110.00 Short span of Critical slab panel (L) (in mm) 2590 Calculated short span to effective depth ratio (L/d) for the corresponding slab 23.55 Basic (L/d) ratio 26.00 Required modification factor for tension reinforcement 0.906 Required Tension reinforcement(Ast) Percentage(%) for short span bottom reinforcement 0.21 Provided Tension reinforcement(Ast) Percentage (%) for short span bottom reinforcement 0.27 Actual Modification factor for tension reinforcement 1.00 Check for Critical beam Effective depth of beam (d) (in mm) 322.00 Critical span (L) (in mm) 4725.00 Cantilever Simply supported Support condition √ One side continuous Both side continuous Basic (L/d) ratio 26.00 Calculated critical span to effective depth ratio (L/d) for corresponding slab 14.67 Check for Critical Column Critical column height 2845 Minimum size of column (mm x mm) 300 x 300 √ Yes Short column effect considered or not No Minimum area of longitudinal reinforcement provided (%) 1.40 Design Philosophy Limit state method Load Combinations 1: DL 1.5 1: LL 1.5 1: EQ - 2: DL 1.2 2: LL 1.2 2: EQ 1.2 3: DL 1.5 3: LL - 3: EQ 1.5 4: DL 0.9 4: LL - 4: EQ 1.5 Whether sample design calculations of foundations, columns, √ Yes beams and slabsare submitted No √ Isolated √ Combined Type of Foundations Raft PILE √ Strap Depth of foundation from ground level to the bottom of footing 1.5 (in m)