ABSTRACT
The objective of this project is to control the railway tracks by using anti-collision techniques. The
model of railway track controller is designed by using 8952 microcontroller to avoid railway
accidents. When we go through the daily newspapers we come across many railway accidents
occurring at unmanned railway crossings. This is mainly due to the carelessness in manual
operations or lack of workers. And also the collision of two trains due to the same track. This model
is implemented using sensor technique. We placed the sensors at a certain distance from the gate
detects the approaching train and accordingly controls the operation of the gate. Also an indicator
light has been provided to alert the motorists about the approaching train.
2
3
ACKNOWLEDGEMENT
We extend our sincere gratitude towards Mr. Praveen Malik for giving us his
invaluable knowledge and wonderful technical guidance.
We express our thanks to all staff members of the Electronics and
Communication department for their kind co-operation and guidance.
We also thank all the other faculty members of ECE department and our
friends for their endless help and support.
Hina Saxena
Anusha Srivastava
Anubha Mishra
Akanksha Gupta
4
CANDIDATE DECLARATION
We hereby declare that the work, which is being presented in the project report, entitled “Fully
Automatic Anti-Collision Train Signalling” and submitted to the Department of Electronics &
Communication, Raj Kumar Goel Institute Of Technology, Ghaziabad is a record of our
work carried under Mr. Praveen Malik.
5
CERTIFICATE
Certified that the work contained in the project report, entitled “Fully Automatic anti-Collision
Train Signalling”, by Hina Saxena (1103331064), Anusha Srivastava (1103331037), Anubha
Mishra (1103331035), Akanksha Gupta (1103331013) is being carried out under my
supervision. The work has been successfully completed to fulfill the requirement of project
report for this semester.
6
List of Figures and Tables
Fig 1.1: Causalities in Train Accidents during 1995-96 to 2006-07……..............8
7
Fig 6.10: Crystal 12 Mhz………………………………………………………….26
8
CONTENTS
Abstract……………………………………………………………………………….. 2
Acknowledgment……………………………………………………………............... 3
Candidate Declaration………………………………………….. ………………….. 4
Certificate…………………………….…………………………………………….... 5
List of Figure……………………………………………………………………….... 6-7
Chapter 1 Introduction……...……………..……………………………………….... 9
Conclusion………………………………………………………………………………27
Bibliography………………………………………………………………………28
9
1.Introduction
Railway is lifeline of India and it is being the cheapest modes of transportation are preferred over
all other means of transportation. When we go through the daily newspapers we come across
many accidents in railroad railings. Railroad-related accidents are more dangerous than other
transportation accidents in terms of severity and death rate etc. Therefore more efforts are
necessary for improving safety. Collisions with train are generally catastrophic, in that the
destructive forces of a train usually no match for any other type of vehicle. Train collisions form
a major catastrophe, as they cause severe damage to life and property. Train collisions occur
frequently eluding all the latest technology.
10
2.Project Background
Railway safety is a crucial aspect of rail operation the world over. Malfunctions resulting in
accidents usually get wide media coverage even when the railway is not at fault and give to rail
transport, among the uninformed public, an undeserved image of inefficiency often fueling calls
for immediate reforms. This paper is aimed at helping the railway administrations concerned to
strengthen their safety culture and develop the monitoring tools required by modern safety
management. Railroad intersections are very unique, special, potentially dangerous and yet
unavoidable in the World. Here two different entities with entirely different responsibilities,
domains, performances come together and converge for a single cause of providing a facility to
the road user. During the normal operation also, there is every possibility of accidents occurring
even with very little negligence in procedure and the result is of very high risk. The potential for
accidents is made higher as the railways control only half the problem. The other half,
meanwhile, cannot really be said to be controlled by one entity, as even though traffic rules and
road design standards supposedly exist, the movements of road users are not organized and
monitored by one specific entity as rigidly as rail movements. The railway systems of Asia and
the Pacific are no exception to this. Each year, accidents at level crossings not only cause
fatalities or serious injuries to many thousands of road users and railway passengers, but also
impose a heavy financial burden in terms of disruptions of railway and road services and
damages to railway and road vehicles and property. A very high number of these collisions are
caused by the negligence, incompetence or incapacity of road vehicle drivers, who by and large
operate their vehicles in environments in which safety consciousness is practically non-existent.
Since it is the railway which must bear the responsibility for ensuring that it is protected from the
transgressions by road users (despite the fact that in many countries the law gives it priority of
passage over road users), it is the railway which also has to shoulder most of the financial burden
of providing this protection. Similarly, it is the railway, which has most of the responsibility for
educating road users on the safe use of its level crossings. Notwithstanding this, it appears that in
many regions, railways are ill-equipped to be in a position to monitor level crossing safety
effectively and to take both corrective and pro-active measures to improve the safety of their
level crossing installations.
11
In the rapidly flourishing country like ours, even though all the latest technologies are there train
collisions are occurring frequently. The railway accidents are happening due to the carelessness
in manual operations or lack of workers. The other main reasons for the collisions of Train are:
1.Train Derailment in curves and bends,2.Running Train collisions with the Standing
Train,3.Train Accidents in Slopes,4.Mis- signaling due to fog or Mist. There is no fruitful steps
have been taken so far in these areas. This paper deals about one of the efficient methods to
avoid train Collision and derailment. Also by using simple electronic components we tried to
automate the control of railway gate in an embedded platform.
12
2.1 Train Accidents
Rear end collision; the other kind is when a train collides into the other that is in front of it,
called a rear end collision.
13
2.2 Methodology
14
3. Literature Review
15
3.2 Proposed System
The proposed Train Anti Collision and Level Crossing Protection System consists of a
self-acting microcontroller and anti-collision technique which works round-the-clock to avert
train collisions and accidents at the level crosses. Thus enhances safety in train operations by
providing a NON-SIGNAL additional safety overlay over the existing signaling system. The
system operates without replacing any of the existing signaling and nowhere affects the vital
functioning of the present safety systems deployed for train operations. The proposed system
gets data from the vibration sensor. The efficiency of the system is expected to be considerably
increased as the proposed system takes inputs from the sensor and also from the level crossing
gates. As more relevant data are included, it is expected that the present system may assist loco
drivers in averting accidents efficiently. As no change is necessary to be made to the
infrastructure of the existing system, the cost of implementation of this system is also less. The
system has been designed and simulated using proteus real time simulation software.
16
4. General Features
Anti-Collision Device:
ACDs have knowledge fixed intelligence. They take inputs from GPS satellite
system for position updates and take decisions for timely auto-application of
brakes to prevent dangerous ‘collisions’ .
1.Advance Sign: This sign tells you to slow your speed and look and listen for
the train, and be ready to stop at the tracks if a train is coming.
17
2. Whistle Indicator: ‘W’, or ‘W/L’ on a square yellow board. The ‘W’ is a
general whistle indicator while the ‘W/L’ stands for Whistle for Level Crossing.
The latter is also seen in Hindi with the characters ‘see/pha’ == ‘seetee bajao -
phatak’).
4. Cross Buks Sign: Cross bucks are located at all grade crossings on both
approaches to the crossing. Form an X via the intersection of two 1200 mm x 200
mm retro-reflective pieces. A cross buck sign provides the last indication to the
driver where the crossing is located.
18
Fig. 4.4: Cross Bucks sign
19
5. Working Model
5.1 Technology used in Model gate control: Using simple electronic device, we have
tried to control the railway gate. A sensor is placed at certain distance of railway gate to detect
the train. When a train comes it detects the train and displayed it on the monitor and then it
controls the railway gate and reduces the railway accident.
5.2 Track switching: Considering a situation where is an express train and a local train is
travelling on the same track in opposite directions; the express train is permitted to travel on the
same track and the local train has to switch on to the other track. Indicator lights have been
provided to avoid collisions. In this, switching operation is performed using a stepper motor. In
practical purposes this can be achieved using electromagnets.
5.3 Anti Collision device: Anti-Collision Devices have knowledge fixed intelligence. They
take inputs from GPS satellite system for position updates and take decisions for timely auto-
application of brakes to prevent dangerous ‘collisions’.
ACDs fitted (both in Locomotive and Guard’s Van of a train) act as a watchdog in the
20
dark as they constantly remain in lookout for other train bound ACDs, within the braking
distance required for their relative speeds.
We use two platforms to make easy model which can make any number of platform. When train
reaches at certain distance from the railway track a set of sensors are placed to detect the train
and two pairs of sensor are placed on other side of track to detect the train.
When the train is at the first pair of sensors it sends a signal to microcontroller to know
the availability of plat form. Hereafter checking availability microcontroller operates stepper
motor to change the track.
21
Fig. 5.5: Combination of Track Switching and gate controlling
22
6. Devices description
6.1. 12012 500 mAmp transformer: 12-0-12 means that the voltage or the potential
difference (p.d.) between each of the end terminal of the secondary winding and the mid-point of
the secondary winding of the transformer is 12V. And, between the two ends of the secondary
winding, you will get 12 + 12 = 24V. 500mA means the current delivery capability of the
secondary winding of the transformer. Normally it is said in VA. In your case it would be 25 x
0.5 = 12VA. The ratings are arrived at based on the requirements of the loads that are to be
connected to the transformer. The limiting criteria is the winding wire thickness and the
insulation of the winding.
6.2 Voltage regulator: We have used 2 types of voltage regulators: 7805 and 7812.
The 78xx is a family of self-contained fixed linear voltage regulator integrated circuits. The 78xx
family is commonly used in electronic circuits requiring a regulated power supply due to their
ease-of-use and low cost. For ICs within the family, the xx is replaced with two digits, indicating
the output voltage (for example, the 7805 has a 5 volt output, while the 7812 produces 12 volts).
The 78xx lines are positive voltage regulators: they produce a voltage that is positive relative to a
common ground.
23
Fig. 6.2: Pin diagram of 89S52 Micro-controller
6.4 Anti collision device: ACDs fixed (both in Locomotive and Guard’s Van of a train) act
as a watchdog in the dark as they continuously remain in lookout for other train bound ACDs,
within the braking distance necessary for their relative speeds. They communicate through their
radios and identify each other. If they happen to find themselves on the same track and coming
closer to each other, they automatically restrain and stop each other, thereby preventing
dangerous head-on and rear-end collisions.
24
6.5 Resistor: A resistor is a passive two-terminal electrical component that implements
electrical resistance as a circuit element. Resistors act to reduce current flow, and, at the same
time, act to lower voltage levels within circuits.
We have used 1K, 10K, 1.2K resistors.
25
6.8 LCD: A liquid-crystal display (LCD) is a flat panel display, electronic visual display,
or video display that uses the light modulating properties of liquid crystals. Liquid crystals do not
emit light directly.
LCDs are available to display arbitrary images (as in a general-purpose computer display) or
fixed images which can be displayed or hidden, such as preset words, digits, and 7-
segment displays as in a digital clock. They use the same basic technology, except that arbitrary
images are made up of a large number of small pixels, while other displays have larger elements.
Fig. 6.9
6.10: Crystal 12 MHz: Standard frequency crystals - we use these crystals to provide a
26
clock input to the microprocessor. It is rated at 20pF capacitance and +/- 50ppm stability. Low
profile HC49/US Package.
27
Conclusion
This project is suitably fulfilled the basic things such as avoidance of accidents inside the gate
and the avoidable of a gatekeeper. It avoids the railway accidents and provides safety. We have
seen little improvement in railway accidents. We also observed stronger safety records in certain
areas and believe they are the result of constant efforts to improve safety. We demonstrate that it
is possible to improve the overall safety of the railway system in India. We believe that success
depends on both the railway industry and the regulator working together to achieve that common
goal. The proposed system provide the means for real time inspection, review and data collection
for the purpose of maintenance on the movable and fixed facilities for the guarantee of operation
safety and maintenance efficiency as well as the safety appraisal decision-making system based
on the share of safety data.
28
Bibliography
1. A complete reference of Micro Controllers, by Natwar Singh.
3. Quantification of the business benefits of positive train control Prepared for the Federal
Railroad Administration, Revised March 15, 2004.
5. Indian Railways Corporate Safety Plan (2003-13), August 2003, Govt. of India, Ministry of
Railways.