PERKINS

Hardware: Phlox Software: 00.0.23


PHLOX_18Jan20_0937

Error Memory

3003 ErrPickUp / [0] SignalLoss


Count: 20 2000 Speed 334,0 1/min
First Occurence: 3196:42:29 3600 PowerSupply 24,29 V
Last Occurence: 18524:49:28 3609 PowerSupplyCurrent 0,20 A
3625 InternTempCaseOutput 34,1 °C
3830 Phase 3

3004 ErrOverSpeed / [2] PickupCamIndex


Count: 94 2000 Speed 4000,0 1/min
First Occurence: 0:48:34 3600 PowerSupply 25,58 V
Last Occurence: 18530:55:57 3609 PowerSupplyCurrent 1,86 A
3625 InternTempCaseOutput 27,7 °C
3830 Phase 5

3005 ErrExtIgnTimingOffs / [1] ShortToPower


Count: 93 2000 Speed 0,0 1/min
First Occurence: 0:05:19 3600 PowerSupply 24,89 V
Last Occurence: 18530:20:19 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 34,5 °C
3830 Phase 0

3005 ErrExtIgnTimingOffs / [0] ShortToGround/OpenCircuit


Count: 36 2000 Speed 0,0 1/min
First Occurence: 3191:11:29 3600 PowerSupply 24,91 V
Last Occurence: 18530:20:19 3609 PowerSupplyCurrent 0,04 A
3625 InternTempCaseOutput 34,5 °C
3830 Phase 0

3036 ErrSynchronisation / [4] CamIndex Counter


Count: 4 2000 Speed 173,6 1/min
First Occurence: 3196:37:08 3600 PowerSupply 20,63 V
Last Occurence: 13358:58:48 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 33,6 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page1
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

3085 ErrPowerSupply / [0] SupplyTooLow


Count: 1 2000 Speed 17,9 1/min
First Occurence: 18517:06:38 3600 PowerSupply 10,78 V
Last Occurence: 18517:06:38 3609 PowerSupplyCurrent 0,06 A
3625 InternTempCaseOutput 36,0 °C
3830 Phase 3

13050 ErrIgnitionCyl1 / [0] Charge error


Count: 94 2000 Speed 124,6 1/min
First Occurence: 0:07:08 3600 PowerSupply 19,30 V
Last Occurence: 18530:20:19 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 34,6 °C
3830 Phase 3

13050 ErrIgnitionCyl1 / [5] Spark duration too short


Count: 125 2000 Speed 160,2 1/min
First Occurence: 13353:35:27 3600 PowerSupply 25,17 V
Last Occurence: 18531:04:06 3609 PowerSupplyCurrent 0,50 A
3625 InternTempCaseOutput 31,9 °C
3830 Phase 5

13050 ErrIgnitionCyl1 / [2] Primary open


Count: 1 2000 Speed 154,5 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,33 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13050 ErrIgnitionCyl1 / [4] Secundary open


Count: 5 2000 Speed 156,8 1/min
First Occurence: 18530:54:46 3600 PowerSupply 19,04 V
Last Occurence: 18530:56:55 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 28,1 °C
3830 Phase 3

13051 ErrIgnitionCyl2 / [0] Charge error


Count: 17 2000 Speed 111,8 1/min
First Occurence: 0:34:07 3600 PowerSupply 24,04 V
Last Occurence: 18525:01:23 3609 PowerSupplyCurrent 0,20 A
3625 InternTempCaseOutput 30,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page2
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13051 ErrIgnitionCyl2 / [5] Spark duration too short


Count: 1 2000 Speed 201,8 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,12 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,12 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13051 ErrIgnitionCyl2 / [2] Primary open


Count: 1 2000 Speed 179,3 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,82 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13052 ErrIgnitionCyl3 / [0] Charge error


Count: 163 2000 Speed 174,9 1/min
First Occurence: 0:05:27 3600 PowerSupply 21,00 V
Last Occurence: 18530:56:55 3609 PowerSupplyCurrent 0,20 A
3625 InternTempCaseOutput 28,1 °C
3830 Phase 3

13052 ErrIgnitionCyl3 / [6] Spark duration too long


Count: 1 2000 Speed 146,4 1/min
First Occurence: 18523:42:40 3600 PowerSupply 18,10 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,07 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13052 ErrIgnitionCyl3 / [3] Secundary short


Count: 1 2000 Speed 146,4 1/min
First Occurence: 18523:42:40 3600 PowerSupply 18,21 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,07 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13052 ErrIgnitionCyl3 / [2] Primary open


Count: 1 2000 Speed 169,8 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,77 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page3
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13053 ErrIgnitionCyl4 / [0] Charge error


Count: 28 2000 Speed 107,7 1/min
First Occurence: 23:08:58 3600 PowerSupply 25,17 V
Last Occurence: 18531:04:07 3609 PowerSupplyCurrent 0,43 A
3625 InternTempCaseOutput 31,9 °C
3830 Phase 5

13053 ErrIgnitionCyl4 / [5] Spark duration too short


Count: 1 2000 Speed 213,6 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,02 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,24 A
3625 InternTempCaseOutput 35,8 °C
3830 Phase 3

13053 ErrIgnitionCyl4 / [6] Spark duration too long


Count: 1 2000 Speed 145,8 1/min
First Occurence: 18523:42:40 3600 PowerSupply 18,08 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13053 ErrIgnitionCyl4 / [3] Secundary short


Count: 1 2000 Speed 145,8 1/min
First Occurence: 18523:42:40 3600 PowerSupply 18,15 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13053 ErrIgnitionCyl4 / [2] Primary open


Count: 1 2000 Speed 181,6 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,87 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13054 ErrIgnitionCyl5 / [0] Charge error


Count: 51 2000 Speed 261,1 1/min
First Occurence: 0:06:51 3600 PowerSupply 24,20 V
Last Occurence: 18525:47:39 3609 PowerSupplyCurrent 0,37 A
3625 InternTempCaseOutput 33,0 °C
3830 Phase 4

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page4
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13054 ErrIgnitionCyl5 / [5] Spark duration too short


Count: 1 2000 Speed 188,5 1/min
First Occurence: 13353:35:27 3600 PowerSupply 21,96 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13054 ErrIgnitionCyl5 / [6] Spark duration too long


Count: 3 2000 Speed 146,1 1/min
First Occurence: 13358:49:30 3600 PowerSupply 18,13 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,06 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13054 ErrIgnitionCyl5 / [3] Secundary short


Count: 1 2000 Speed 146,1 1/min
First Occurence: 18523:42:40 3600 PowerSupply 18,24 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,06 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13054 ErrIgnitionCyl5 / [2] Primary open


Count: 1 2000 Speed 160,9 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,82 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 36,0 °C
3830 Phase 3

13055 ErrIgnitionCyl6 / [0] Charge error


Count: 37 2000 Speed 102,5 1/min
First Occurence: 0:06:01 3600 PowerSupply 24,40 V
Last Occurence: 18528:55:49 3609 PowerSupplyCurrent 0,20 A
3625 InternTempCaseOutput 27,1 °C
3830 Phase 4

13055 ErrIgnitionCyl6 / [5] Spark duration too short


Count: 1 2000 Speed 198,9 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,06 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,11 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page5
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13055 ErrIgnitionCyl6 / [6] Spark duration too long


Count: 1 2000 Speed 140,2 1/min
First Occurence: 18523:42:40 3600 PowerSupply 17,64 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,18 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13055 ErrIgnitionCyl6 / [3] Secundary short


Count: 1 2000 Speed 139,6 1/min
First Occurence: 18523:42:40 3600 PowerSupply 17,25 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,19 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13055 ErrIgnitionCyl6 / [2] Primary open


Count: 1 2000 Speed 175,4 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,81 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13056 ErrIgnitionCyl7 / [0] Charge error


Count: 5 2000 Speed 113,8 1/min
First Occurence: 3167:37:49 3600 PowerSupply 23,95 V
Last Occurence: 18525:01:23 3609 PowerSupplyCurrent 0,20 A
3625 InternTempCaseOutput 30,9 °C
3830 Phase 3

13056 ErrIgnitionCyl7 / [5] Spark duration too short


Count: 19 2000 Speed 160,1 1/min
First Occurence: 13353:35:27 3600 PowerSupply 26,09 V
Last Occurence: 13355:32:35 3609 PowerSupplyCurrent 0,58 A
3625 InternTempCaseOutput 42,8 °C
3830 Phase 5

13056 ErrIgnitionCyl7 / [4] Secundary open


Count: 1 2000 Speed 201,8 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,12 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,11 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page6
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13056 ErrIgnitionCyl7 / [6] Spark duration too long


Count: 255 2000 Speed 413,6 1/min
First Occurence: 13353:37:43 3600 PowerSupply 25,19 V
Last Occurence: 18531:04:05 3609 PowerSupplyCurrent 0,78 A
3625 InternTempCaseOutput 31,9 °C
3830 Phase 5

13056 ErrIgnitionCyl7 / [3] Secundary short


Count: 159 2000 Speed 283,9 1/min
First Occurence: 13353:37:43 3600 PowerSupply 25,18 V
Last Occurence: 18531:04:05 3609 PowerSupplyCurrent 0,64 A
3625 InternTempCaseOutput 31,9 °C
3830 Phase 5

13056 ErrIgnitionCyl7 / [1] Primary short


Count: 1 2000 Speed 169,4 1/min
First Occurence: 14200:18:26 3600 PowerSupply 20,63 V
Last Occurence: 14200:18:26 3609 PowerSupplyCurrent 0,08 A
3625 InternTempCaseOutput 33,7 °C
3830 Phase 3

13056 ErrIgnitionCyl7 / [2] Primary open


Count: 1 2000 Speed 179,3 1/min
First Occurence: 18530:54:46 3600 PowerSupply 21,00 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13057 ErrIgnitionCyl8 / [0] Charge error


Count: 6 2000 Speed 135,7 1/min
First Occurence: 0:06:51 3600 PowerSupply 18,70 V
Last Occurence: 18525:05:15 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 32,0 °C
3830 Phase 3

13057 ErrIgnitionCyl8 / [5] Spark duration too short


Count: 2 2000 Speed 194,6 1/min
First Occurence: 3196:15:10 3600 PowerSupply 21,98 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page7
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13057 ErrIgnitionCyl8 / [4] Secundary open


Count: 1 2000 Speed 194,6 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,01 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13057 ErrIgnitionCyl8 / [6] Spark duration too long


Count: 8 2000 Speed 1250,3 1/min
First Occurence: 13353:35:49 3600 PowerSupply 25,62 V
Last Occurence: 13353:37:37 3609 PowerSupplyCurrent 1,56 A
3625 InternTempCaseOutput 36,8 °C
3830 Phase 5

13057 ErrIgnitionCyl8 / [3] Secundary short


Count: 2 2000 Speed 1677,0 1/min
First Occurence: 13353:37:03 3600 PowerSupply 25,75 V
Last Occurence: 13353:37:36 3609 PowerSupplyCurrent 1,70 A
3625 InternTempCaseOutput 36,8 °C
3830 Phase 5

13057 ErrIgnitionCyl8 / [1] Primary short


Count: 1 2000 Speed 168,4 1/min
First Occurence: 14200:18:26 3600 PowerSupply 20,60 V
Last Occurence: 14200:18:26 3609 PowerSupplyCurrent 0,07 A
3625 InternTempCaseOutput 33,7 °C
3830 Phase 3

13057 ErrIgnitionCyl8 / [2] Primary open


Count: 1 2000 Speed 169,8 1/min
First Occurence: 18530:54:46 3600 PowerSupply 20,78 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [0] Charge error


Count: 5 2000 Speed 104,5 1/min
First Occurence: 23:08:58 3600 PowerSupply 24,28 V
Last Occurence: 18524:31:16 3609 PowerSupplyCurrent 0,40 A
3625 InternTempCaseOutput 35,3 °C
3830 Phase 5

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page8
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13058 ErrIgnitionCyl9 / [6] Spark duration too long


Count: 39 2000 Speed 145,3 1/min
First Occurence: 6251:39:31 3600 PowerSupply 18,04 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [3] Secundary short


Count: 20 2000 Speed 145,3 1/min
First Occurence: 6251:39:33 3600 PowerSupply 18,02 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [5] Spark duration too short


Count: 1 2000 Speed 205,3 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,18 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,13 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [4] Secundary open


Count: 1 2000 Speed 205,3 1/min
First Occurence: 13353:35:27 3600 PowerSupply 21,96 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,13 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [1] Primary short


Count: 1 2000 Speed 168,7 1/min
First Occurence: 14200:18:26 3600 PowerSupply 20,45 V
Last Occurence: 14200:18:26 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 33,7 °C
3830 Phase 3

13058 ErrIgnitionCyl9 / [2] Primary open


Count: 1 2000 Speed 182,9 1/min
First Occurence: 18530:54:46 3600 PowerSupply 21,05 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page9
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13059 ErrIgnitionCyl10 / [0] Charge error


Count: 7 2000 Speed 61,2 1/min
First Occurence: 23:27:36 3600 PowerSupply 24,54 V
Last Occurence: 18524:33:52 3609 PowerSupplyCurrent 0,24 A
3625 InternTempCaseOutput 32,0 °C
3830 Phase 5

13059 ErrIgnitionCyl10 / [5] Spark duration too short


Count: 2 2000 Speed 192,1 1/min
First Occurence: 13353:35:27 3600 PowerSupply 21,52 V
Last Occurence: 13353:58:23 3609 PowerSupplyCurrent 0,05 A
3625 InternTempCaseOutput 41,1 °C
3830 Phase 3

13059 ErrIgnitionCyl10 / [4] Secundary open


Count: 1 2000 Speed 198,9 1/min
First Occurence: 13353:35:27 3600 PowerSupply 22,07 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,11 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13059 ErrIgnitionCyl10 / [6] Spark duration too long


Count: 22 2000 Speed 349,2 1/min
First Occurence: 13353:49:38 3600 PowerSupply 26,17 V
Last Occurence: 13358:47:45 3609 PowerSupplyCurrent 0,82 A
3625 InternTempCaseOutput 43,2 °C
3830 Phase 5

13059 ErrIgnitionCyl10 / [3] Secundary short


Count: 10 2000 Speed 208,5 1/min
First Occurence: 13353:49:39 3600 PowerSupply 26,18 V
Last Occurence: 13358:47:45 3609 PowerSupplyCurrent 0,64 A
3625 InternTempCaseOutput 43,2 °C
3830 Phase 5

13059 ErrIgnitionCyl10 / [2] Primary open


Count: 2 2000 Speed 175,4 1/min
First Occurence: 14200:18:26 3600 PowerSupply 20,97 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page10
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13060 ErrIgnitionCyl11 / [5] Spark duration too short


Count: 2 2000 Speed 203,9 1/min
First Occurence: 3196:15:10 3600 PowerSupply 22,13 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,12 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13060 ErrIgnitionCyl11 / [4] Secundary open


Count: 2 2000 Speed 203,9 1/min
First Occurence: 3196:15:10 3600 PowerSupply 21,56 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,12 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13060 ErrIgnitionCyl11 / [0] Charge error


Count: 3 2000 Speed 120,6 1/min
First Occurence: 3196:33:36 3600 PowerSupply 24,39 V
Last Occurence: 18524:33:09 3609 PowerSupplyCurrent 0,25 A
3625 InternTempCaseOutput 31,2 °C
3830 Phase 4

13060 ErrIgnitionCyl11 / [6] Spark duration too long


Count: 5 2000 Speed 994,5 1/min
First Occurence: 13358:49:30 3600 PowerSupply 23,51 V
Last Occurence: 17585:56:45 3609 PowerSupplyCurrent 0,87 A
3625 InternTempCaseOutput 30,6 °C
3830 Phase 5

13060 ErrIgnitionCyl11 / [3] Secundary short


Count: 3 2000 Speed 180,7 1/min
First Occurence: 13358:49:30 3600 PowerSupply 20,96 V
Last Occurence: 14850:36:09 3609 PowerSupplyCurrent 0,10 A
3625 InternTempCaseOutput 33,0 °C
3830 Phase 3

13060 ErrIgnitionCyl11 / [2] Primary open


Count: 2 2000 Speed 181,6 1/min
First Occurence: 14200:18:26 3600 PowerSupply 21,03 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38


Version: 5.21 Identifier: 21729 Maximum Level: 2 18531:04:09 Page11
PERKINS
Hardware: Phlox Software: 00.0.23
PHLOX_18Jan20_0937

13061 ErrIgnitionCyl12 / [6] Spark duration too long


Count: 181 2000 Speed 146,1 1/min
First Occurence: 0:07:36 3600 PowerSupply 18,28 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,05 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13061 ErrIgnitionCyl12 / [3] Secundary short


Count: 79 2000 Speed 146,1 1/min
First Occurence: 0:07:37 3600 PowerSupply 18,13 V
Last Occurence: 18523:42:40 3609 PowerSupplyCurrent 0,05 A
3625 InternTempCaseOutput 32,4 °C
3830 Phase 3

13061 ErrIgnitionCyl12 / [0] Charge error


Count: 9 2000 Speed 243,8 1/min
First Occurence: 3196:43:41 3600 PowerSupply 22,24 V
Last Occurence: 13358:56:22 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 34,4 °C
3830 Phase 3

13061 ErrIgnitionCyl12 / [5] Spark duration too short


Count: 3 2000 Speed 1197,7 1/min
First Occurence: 13353:35:27 3600 PowerSupply 25,02 V
Last Occurence: 13358:50:29 3609 PowerSupplyCurrent 0,75 A
3625 InternTempCaseOutput 32,2 °C
3830 Phase 5

13061 ErrIgnitionCyl12 / [4] Secundary open


Count: 1 2000 Speed 188,5 1/min
First Occurence: 13353:35:27 3600 PowerSupply 21,92 V
Last Occurence: 13353:35:27 3609 PowerSupplyCurrent 0,09 A
3625 InternTempCaseOutput 35,7 °C
3830 Phase 3

13061 ErrIgnitionCyl12 / [2] Primary open


Count: 2 2000 Speed 160,9 1/min
First Occurence: 14200:18:26 3600 PowerSupply 20,76 V
Last Occurence: 18530:54:46 3609 PowerSupplyCurrent 0,02 A
3625 InternTempCaseOutput 35,9 °C
3830 Phase 3

DcDesk 2000 Operating time 18/01/2020 09.38