You are on page 1of 73
(C$ 29.120.70 SR EN 61810-1 ASN® CEI 61810-1 STANDARD ROMAN Decembnie 2008 Relee electromecanice elementare Partea 1: Prescriptil generale Electromechanical elementary relays - Part 1: General requirements Relais électromécaniques élémentaires - Partie 1: Exigences générales APROBARE Aprobat de Directorul General al ASRO la 15 decembrie 2008 Standardul european EN 61810-1:2008 a fost adoptat prin metoda notei de confirmare si are statutul unui standard roman Inlocuieste SR EN 61810-1:2005 CORESPONDENTA | Acest standard este identic cu standardul european EN 61810-1:2008 This standard is identical with the European Standard EN 61810-1:2008 La présente norme est identique a la Norme européenne EN 61810-1:2008 "ASOCIATIA DE STANDARDIZARE DIN ROMANIA (ASRO) ‘Sir. Mendeleev nr. 21-25, cod 010362, Bucuresti Director General: Tel: +40 21 318 32 96, Fax: +40 21 318 08 70 Direcia De Standardizare: Tel. +40 21 310 17 30, +40 21 $10 48,08, +40 21 312 47 44, Fax: +4021 91958 70 Direcia Publicti - Serv. VanzervAbonamerto: Tel. +40 21 316 77 26, Fax + 40 21 317 25 14, +40 21 312 94 85 ‘Servic Redactis- Marketing, Drepturi de Autor + 40 21 316.09.74 Reprochcerea say ular neal sa para pezeiul standard rc publica pa ree procedeu eaRo) (electronic, mecanic, fotocopiere, microfilmare etc.) este interzis® dacs nu exist acordul soris al ASRO- Ref: SR EN 61810-1:2008 Edita 3 EUROPEAN STANDARD EN 61810-1 NORME EUROPEENNE EUROPAISCHE NORM June 2008 ves 2812070 Suprmden EN 161012004 English version Electromechanical elementary relays - Part 1: General requirements (IEC 61810-1:2008) Relais électromécaniques élémentaires - Elektromechanische Elementarrelais - Partie 1: Exigences générales Teil 1: Allgemeine Anforderungen (CEI 61810-1:2008) (IEC 61810-1:2008) ( ‘This European Standard was approved by CENELEC on 2008-06-01. CENELEC members are bound to comply with the CENIGENELEG Internat Regulations which stipulate the conditions for giving this European Standard the status of national stendaré without any alteration, Upto-date sts and bibliographical references concerning such netional standards may be obtained on ‘apalcaton to tre Central Sacretaiat or to any CENELEC member. ‘This European Siandard exists in two oficial versions (English and German). A version in any ether language ‘mado by translation under the responsibilty of a CENELEC momber into its own language and notfed to the Central Secretarial has the seme status as the official versions, CENELEC members are the national olectrotechnical committees of Austia, Belgium, Bulgaria, Cyprus, the Czech Republic, Denmark, Estonia, Finland, France, Gormany, Groeco, Hungary, Iceland, Irland, tly, Latvia, LUthuanie, Luxembourg, Malta, the Netheriande, Norway, Poland, Pertugel, Romani, Siovakia, Slovenia, Spain, ‘Sweden, Switzeriand and the United Kingdom, CENELEC European Committee for Electrotechnical Standardization Comité Européen de Normalisation Electrotechnique Europaisches Komitee fUr Elektrotechnische Normung Central Secretariat: rue de Stassart 35, B -1050 Brussels (© 2008 CENELEC.- _Allrights of exploitation in any form and by any means reserved wore for CENELEG members. Ref, No. EN 81810-:2008 EN 61810-1:2008 +2 Foreword The text of document 94/267/FDIS, future edition 3 of IEC 61810-1, prepared by IEC TC 94, Alkor-nothing electrical relays, was submitted to the IEC-CENELEC parallel vote and was approved by CENELEC es EN 81810-1 on 2008-08-01, ‘This European Standard supersedes EN 61810-1:2004 ‘The relevant modifications compared to EN 61810-1:2004 are: update of references; renumbering of clauses to bring them into a more logical order; inclusion of contact load categories (same as in EN 61810-2 and EN 61810-7); Clarifications concerning electrical endurance (Clause 11); = inclusion of provisions for insulation coordination in accordance with the basic safety standards EN 60664-3, EN 60664-4 and EN 6064-5 (Clause 13); renumbering of all annexes in the order they are referenced in the body of the standard; Inclusion of new Annex C (normative) for the test setup, and new Annex D (informative) for special loads (based upon similar annexes in EN 61810-2 and EN 61810-7); improvement of Annex 8 covering inductive contact loads. The following dates were fixed latest date by which the EN has to be implemented at national level by publication of an identical rational standard or by endorsement (Gop) 2009-02-01 latest date by which the national standards conticting with the EN have to be withdrawn (dow) 2011-08-01 Annex ZA has been added by CENELEC. Endorsement notice ‘The text of the International Standard IEC 61810-1:2008 was approved by CENELEC as a European Standard without any modification, In the official version, for Bibliography, the following notes have to be added forthe standards indicated 1EC.60585-1 + At NOTE Harmonized os EN 605354 2002 modified) + A1:2008 (nt modes) IEG 6095-15 NOTE. Harmonized oo EN 60896-11200 (nat mete. IEC OOTIO1 +A1 NOTE. Hormonized as EN 60730-11995 (meoifed) + AT:1287(mostiod IEC 6004751 NOTE. Hormonized an EN 60947-5:1:2004 (nt mee). vec 60950-1 NOTE Harmonized as EN 60950-1:2006 (modified). 23 EN 61810-1:2008 Annex ZA. (normative) Normative references to international publications with their corresponding European publications ‘The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies. NOTE When an inimationspublcstion has been mestied by commen medications, indented by (rid), the ‘pple. Publication Year Title ENIHO IEC 60038 (mod) 1983 IEC standard voltages” HD 472 81 3 7 + corr February - : AL AL 1994 AZ 1997 IEC 60050 Series International Electrotechnical Vocabulary — (EV) IEC 60068-2-2 2007 Environmental testing - EN 60068~ Part 2-2: Tests - Test B: Dry heat IEC 60068-2-17 1894 Environmental testing - EN 60088-2-17 Part 2: Tests - Test Q: Sealing 1EC 60068-2-20 1979 Environmental testing - +A2 1987 Part 2: Tests - Test T: Soldering HD 323.2.20 $3, JEC 60085 2004 Electrical insulation - Thermal classification EN 60085” lec 60112 2003 Method for the determination of the proof EN 60112 and the comparative tracking indices of solid insulating materials IEC 60364-4-44 2007 Low voltage electrical installations - e Part 4-44; Protection for safely - Protection against voltage disturbances and electromagnetic disturbances IEC 60417 Data- Graphical symbols for use on equipment - base IEC 60864-1 2007 Insulation coordination for equipment within EN 60664-1 low-voltage systems ~ Part 1: Principles, requirements and tests lec s0884-3 2003 Insulation coordination for equipment within EN 60664-3, low-voltage systems - Part 3: Use of coaling, potting or moulding for protection against pollution lec 0864-4 2005 Insulation coordination for equipment within EN 60664-4 low-voltage systems - + corr. October Part 4: Consideration of high-frequency voltage stress "I The tile of HD 472 $1 is: Nominal voltages for low voltage public oe icity supply systems. 7) EN G08S is superseded by EN 60085:2008, which Is based on IEC 60085:2007, 2007 1904 1988 2004 2003, 2007 2003 2008 2008 EN 61810-1:2008 Publication IEC 60664-5 IEC 60698-2-11 IEC 60895-2-12 TEC 60695-2-13, IEC 60695-10-2 \ec 60721 AI A2 3 EC 60999.1 IEC 61210 (mod) lec 61760-1 lec 61984 Year 2007 2000 2000 2000 2000 2008 1994 4995 1996 1909 1983 2006 2001 Tile END Insulation coordination for equipment within EN 60664-5, low-voltage systems - Part 6: Comprehensive method for determining clearances and creepage distances equal to or less than 2 mm Fire hazard testing - EN 60695.2-10 Pari 2-10: Glowing/hot-wire based test ‘methods - Glow-wire apparatus and common test procedure Fire hazard testing - EN 60898-2-11 Part 2-11: Glowing/hot-wire based test methods - Giow-wire flammability test method for end-products Fire hazard testing - EN 60695-2-12 Part 2-12: Glowing/hot-wire based test mathods - Glow-wire flammability test method for materials Fire hazard testing - EN 60695-2-13 Parl 2-13: Glowing/hot-wire based test methods - Glow-wire ignitabilty test method for materials Fire hazard testing - EN 60895-10-2 Part 10-2: Abnormal heat - Ball pressure test Classification of environmental conditions - EN 60721-3-3 Part 3: Classification of groups of z environmental parameters and their AQ severities - Section 3: Stationary use at weatherprotected locations Connecting devices - Electrical copper EN 6090-4 ‘conductors - Safety requirements for screw-type and screwless-type clamping units - Part 1: General requirements and particular requirements for clamping units for conductors from 0,2 mm up to 35 mm (included) Connecting devices - Flat quick-connect EN 61210 terminations for electrical copper conductors ~ Safety requirements Surface mounting technology = EN 61760-1 Parl 1: Standard method for the specification Of surface mounting components (SMDs) ‘Connectors - Safety requirements and tasis EN 61984 Year 2007 2001 2001 2001 2001 2003 1995 1997 2000 1995 2008 2001

You might also like