4.

Anchorage on Concrete (L- Bracket base plate connection concrete)

M12 THREADED
ROD SS316 Hef 70mm

POLYSTYRENE

FILLED WITH SAME GRC


MATERIAL

Reaction for Anchor Check [1.35DL+1.5WLS ETAG Load Combination]

Reaction along the X direction Fx_bot_a_max := 0.125 kN Fx_top_a_max := 0.125 kN

Reaction along the Y direction Fy_bot_a_max := 3.096 kN

Reaction along the Z direction Fz_bot_a_max := 4.987 kN Fz_top_a_max := 6.789 kN

Maximum Loads for TOP Bracket: Input MKT software

Reaction Along with direction Z Fz_top_a_max := Fy_fisc = 6.789 kN

Moment on X axis Mx_fisc = Fy_fisc *Lu1 = 0.510 kN.m

You might also like