Professional Documents
Culture Documents
Touch Probes
Transmission
Systems
Laser
Software
OPTICAL TRANSMISSION SYSTEM
FOR MACHINING CENTRES AND MILLING MACHINES
Toolsetting Arms
The spindle mounted E83 MIDA probing system with optical All elements of the E83 system are designed to withstand
transmission for part, setting and inspection consists of the the most difficult shop floor conditions and their modularity
following elements: allows selection of the most suitable configuration for each
application.
Probe Module
Detects part co-ordinates or dimensions, before and after Marposs also offers a wide range of software packages for
machining cycles. the most widely used CNCs, which includes macros easily
Tool & Process
The probe is mounted on a transmitter that transmits the programmable for part checking and measuring during
Monitoring
measuring data to the CNC using an infrared signal and via a machining.
receiver and an interface.
The E83WA transmitter may be used in multi-spindle Advantages
applications.
• System modularity
Receiver Module • Full transmission range
Receives the signals issued by the transmitter and sends them • Full 360° transmission envelope
to the CNC interface unit. • Compact individual elements
Accessories
• Easy installation
Interface Module • High performance
Processes the data received by the receiver and sends it to the • Possibility for application on multi-spindle machines
machine tool CNC, where it is saved in variable macros.
E83MC 1
Probe module
L L
L1
Ø60
L1
Ø60
Touch Probes
D
E83 E83WA
Transmission
0°
10°
Systems
20°
30°
TX 90° 35°
40°
TX 70° 0°
10°
TX 35° 20°
50°
30°
40°
60°
50°
70° 60°
Laser
70°
80°
80°
90° 90°
100°
100° 1.0 m
(3.28 ft)
110°
1.5 m
Software
(4.92 ft)
110° 2.0 m 120°
(6.56 ft)
130° 2.5 m
(8.2 ft)
120°
3.0 m 140°
(9.84 ft)
150° 3.5 m
130°
(11.48 ft)
4.0 m 160°
140° (13.12 ft)
Toolsetting Arms
150°
5.0 m
(16.40 ft)
160°
Transmitter alignment
The center of the stylus can be aligned with the spindle axis using a ball inserted between the transmitter and the taper or
with a special X-Y adjusting plate (accessory)
Accessories
2 E83MC
Technical specifications
TRANSMISSION X,Y 0,5÷0,95 N
5m E83 MEASURING probe TT25:
DISTANCE Z 5,8 N
3m E83WA
with 1 receiver FORCES
with standard stylus X,Y 2 N
• Machine M code probe T25:
Optical: Z 12 N
TRANSMISSION • Automatic
Touch Probes
ACTIVATION X,Y 11,6 mm
probe TT25:
Mechanical: Microswitch on taper OVERTRAVEL Z 4 mm
with standard stylus
• Machine M code X,Y 11,2 mm
TRANSMISSION Optical: probe T25:
• Programmable timer Z 4 mm
DEACTIVATION
Mechanical: Microswitch on taper PROTECTION
RATING IP68
TRANSMISSION (IEC 60529)
35° / 70° / 90° E83
OPTICAL AXIS
90° E83WA
ANGLE
Transmission
MAXIMUM
Systems
ACTIVATION AND 3,5 m E83 BATTERY CONTINUOUS
DEACTIVATION 3m E83WA RECOMMENDED STAND-BY TIME
(1 x 9V RUNNING TME
DISTANCE BATTERY (days)
battery) (hours)
0 ÷ 55 °C
Operation E83 E83WA E83 E83WA
TEMPERATURE 32 ÷ 131 °F
RANGE Duracell MN 1604
-10 ÷ 70 °C
Storage Alkaline Philips 1604 90 100 410 450
14 ÷ 158 °F
Varta 4022
REPEATABILITY (2 ) TT series probes (TT25 and TT60): 1 µm Accu TL 5306
with standard stylus and
T series probes (T25, TL25 e T36): 0,5 µm Lithium 300 330 1400 1550
Kodak U9VL
Laser
speed 600 mm/min
Interface module
Software
The E83 interface used to connect with the machine CNC is 3. Interface integrated in the receiver (E83RXI), for decoding
available in three versions to satisfy the most diverse installation the optical signal issued by the transmitter and sending
requirements: it directly to the CNC without using a separate interface
1. Compact E83C for installation inside the electrical unit.
cabinet on a DIN - TS35 rail. A tool checking probe can be
connected to the same interface module using an E32R
cable. Connection of the I/Os and the optical receivers with A = power ON A
removable clamps reduces connection times.
Toolsetting Arms
B = probe status MARPOSS
C = low battery B
2. E83T for lathes and turning centers, is equally compact D = error condition E83
in size but with the possibility of programming individual E = I/O terminal board C
Power
Probe
F = receiver connection terminal board
activation of up to (4) different probes installed on the same Low
battery
Error D
machine. This interface is only for use with E83MC and
E83WA transmitter.
F E
Technical specifications
Tool & Process
ery
86
batt
(programmable N.C. or
±50 V ±40 mA LOW BATTERY
r
Erro
E83MC 3
Receiver module 92 57
80 28
There are two types of receiver modules:
• E83 RX
• E83 RXI (with integrated interface): internal switches can
be used to reduce the reception range by 25% and 50%
Touch Probes
110
Technical specifications
Yellow (A): Power ON
E83RXI
System codes
Software
BT30 4390190123
E83 BT40 4390190112 E83C
35° 6871832001 BT50 4390190113 8304850020
70° 6871832011 CAT40 4390190124 6871830000
90° 6871832021 4390190125 E83T
Toolsetting Arms
For a full list of address locations, please consult the Marposs official website
Accessories
MARPOSS, and Marposs product names/signs mentioned or shown herein are registered trademarks or trademarks of Marposs in
the United States and other countries. The rights, if any, of third parties on trademarks or registered trademarks mentioned in the present
publication are acknowledged to the respective owners.
Marposs has an integrated system to manage the Company quality, the environment and safety, attested by ISO 9001, ISO
14001 and OHSAS 18001 certifications. Marposs has further been qualified EAQF 94 and has obtained the Q1-Award.
www.marposs.com
4 E83MC