RISK OF CONTAMINATION Clean up any spills after performing these operations, with a spill

kit that conforms to your local and national regulations. Make sure that filters are disposed of
correctly in a way that meets the local and national environmental regulations. 2. Remove the
cap of the air vent, renew the air vent filter element and install the air vent cap > Note: Only
remove the cap to change the filter, not the complete vent housing. 2 Refer to 6.3.6 - 500
Hours maintenance schedule. DANGER SKIN PENETRATION HAZARD Hydraulic fluid under pressure can
penetrate the skin, which will result in serious injury or death. If fluid is injected under the skin, it must
be surgically removed or gangrene will result. GET MEDICAL HELP IMMEDIATELY. ALWAYS use a piece of
cardboard to check for leaks. DO NOT USE YOUR HAND. Make sure all hydraulic pressure has been
released and the system has cooled before working on the hydraulic system. 1. Clean the top of the
hydraulic tank. Disconnect return pipe and remove return filter housing. Note: Filter housings and pipes
will contain fluid which will require collecting and disposing of in a suitable container. 2. Remove and
dispose of the three filter elements. 1 2 3. Install new filter elements >