You are on page 1of 1

RISK OF CONTAMINATION Clean up any spills after performing these operations, with a spill kit that

conforms to your local and national regulations. Make sure that filters are disposed of correctly in a way
that meets the local and national environmental regulations. DANGER SKIN PENETRATION HAZARD
Hydraulic fluid under pressure can penetrate the skin, which will result in serious injury or death. If fluid
is injected under the skin, it must be surgically removed or gangrene will result. GET MEDICAL HELP
IMMEDIATELY. ALWAYS use a piece of cardboard to check for leaks. DO NOT USE YOUR HAND. Make
sure all hydraulic pressure has been released and the system has cooled before working on the hydraulic
system. 1. Drain the hydraulic fluid from the tank into suitable capacity containers > 1 Refer to 6.4.2 -
Fluid drain points to drain and 6.5 - Lubricants and fluids for tank capacity. 2. Clean the outside of the
tank and surrounding area to prevent contamination then remove the tank access covers. 3. Clean the
tank of any sediment