Relays
Control units
14.06.2016 Basic Electric Training 2
A WIRTGEN GROUP COMPANY
Example
STRUCTURE
MAIN CABINET
Differences:
Contactor
Manufacturer
Size
Motor-protection-relay
Power
Terminals
Cable
with or without plug
Electric motor
(star or delta)
Values
Function
MOTOR PROTECTION
SWITCH
Protection against:
Short circuit
Overload (current too high)
Missing phase
Function: bi-metal
Siemens Siemens
„old“ model „new“ model
Reset: manually
Schneider
motorstarter
Values
Function
MOTOR PROTECTION
RELAY
Protection against:
Short circuit
Overload (current too high)
Missing phase
Function: bi-metal
Values
Function
Troubleshooting
ELECTRICAL
MOTOR-PROTECTION-
SWITCH „ZEV“
Protection against:
Short circuit
Overload (current too high)
Connection cable
Function: electronic
Message from ZEV to PLC
PLC switches OFF the drive
Current sensor
ZEV-XSW-25 M10019255
ZEV-XSW-65 M10013727
ZEV-XSW-145 M10021185
ZEV-XSW-820 M10019256
Connection cable
ZEV-XVK-20 M10013728
ZEV-XVK-80 M10019257
Motor current
Auxiliary contact NC
Auxiliary contact NO
…
Overload
Overtemperature
Ground fault
Missing phase
Current imbalance
System fault
1 Sensor fault / damaged cable
2 EEPROM fault (internal storage)
3 Evaluation unit
Values
Function
Troubleshooting
CURRENT MONITORING
RELAY
Protection against:
Overload (current too high)
Function: electrically
Message from device to PLC
PLC switches OFF the drive
Reset: automatically
Function: electrically
Message from device to PLC
Auxiliary contacts PLC switches OFF the drive
Reset: automatically
Main terminal (output)
Protection against:
Current monitoring relay
Overload (current too high)
Main terminals (input)
Function: electrically
Main terminals (output)
Message from device to PLC
Reset: automatically
With pushing the SET-button long again you’ll get back to the main menu.
Independent of the selected menu it’s possible to get to the next parameter with pushing the SET-button short.
With the arrow buttons it is possible to change the selected parameter.
OFF
Rated current
OFF
OFF
5 minutes
no
no
no
no
Is
NC
Values
Function
CONTACTORS
Values
Function
RELAYS
Overview of types
CONTROL UNITS
Different manufacturers:
VIPA PLC of MREVO2
Siemens
VIPA
Schneider
Bosch Rexroth
Overview
TERMINALS
5 6
3 4 3 4
1 2 1 2 3 1 2 1 2
Star / Delta
CONNECTION MOTOR
400V AC 3-phase
Between 2 phases 400V AC
Between 1 phase and N/ground 230V AC
L1 L1
230/400V instead of 400/690V, means that a single coil of the motor can handle max. 230V.
In this case, the engine has to be connected in STAR mode
Overview
Function
FREQUENCY DRIVES
Motors without frequency drives are operated with the generator frequency (diesel speed)!
Values: voltage constant, 400V AC
current maximum = 100%, actual current depends on the mechanical load of the motor
frequency variable, higher frequency = higher speed, e.g. 50Hz =1000rpm, 60Hz = 1200rpm
Frequency drive
Converts the input frequency to
the required frequency
Input 50-60 Hz // Output 35(20)-55 Hz
Overview
Function
Troubleshooting
RCD-SWITCH
The RCD will trip, if there is any ground fault at the machine!
There’s only one RCD for each machine including all drives. To troubleshoot these faults do following:
Start the machine in manual mode.
Start each drive separately.
If e.g. the feeder is switched on and the RCD trips, the fault is located.
After that, disconnect one of the two feeder motors, if the RCD trips again the faulty drive is located (motor or cable)
Visible check of the cable
Check the motor and the cable with a isolation multimeter.
Overview
EMERGENCY STOP
RELAYS
14.06.2016 42