1.0 Purpose:
The purpose of this method statement is to outline the typical requirements which shall be taken
into consideration for the activity of floor screed works in Vertical & Slope Tower
2.0 Scope:
The scope of this method statement is to define the procedure that shall be followed for the floor
screed works inside the apartments in vertical and slope tower.
Required inspections shall be carried out in order to verify that the screed works are in compliant
as per the specified specification and the construction drawing.
3.0 Definition:
5.0 Responsibilities:
Ensure that adequate facilities, resources and equipment are provided to the work to
avoid injury, health impairment or damage & to ensure providing quality works
within the planned timescale.
Page 3 of 8
Doc No : ATR-SPLL-CV-MST-0038
Rev. No : 00
Organize the site so that screed works are carried out as per this method statement
and project specifications with a minimum risk to men, equipment and materials.
Adhere to the project specific quality management program and HSE requirements.
Coordinate/ Ensure that the floor screed works are executed adhering to the quality
and safety requirements. Supervise the works during the execution.
Workers carry out their work in such a way that they don't create for themselves or
any other person risk to health & safety, and don't impact the environment to the
maximum extent possible or affect the quality of work.
Ensure that all workers have a safe place of work, advice safe system of work and
provide adequate instructions, training and supervision to enable employees to work
safely.
Carry out site survey on daily basis to ensure that the HSE methods of working are
in operation & that all regulations are being observed.
Report, determine & analyze the cause of any accident or dangerous occurrence and
recommend measures for preventing recurrence.
5.6 Surveyor
Responsible to make the markings for correct finishing levels and general
arrangements layouts as per approved drawings.
Page 4 of 8
Doc No : ATR-SPLL-CV-MST-0038
Rev. No : 00
6.0 Methodology
All work will be set out (or) positioned as accurately as possible as Site Engineer / CM
per the GAD layout. In case if any difficulty is being experienced
in achieving accuracy, will be discussed with Consultant for
further needful.
Approved bonding agent will be used at the surface of old concrete Site Engineer
to have proper bonding with the fresh screed as per the
manufacture instructions.
The foreman and respective site engineer will ensure that the Construction
delivery, discharging, placing and leveling of the screed are all in Manager, Site
relevant to acceptance criteria and visually checking the Engineer, QC
consistency of the screed being placed. Engineer
Page 5 of 8
Doc No : ATR-SPLL-CV-MST-0038
Rev. No : 00
6.7 Inspections
Screed shall be cured by mist spray of water to minimize early Project Engineer, QC
shrinkage cracking and duly covered with wet hessian cloth for a Engineer
minimum period of 3 days.
Labour requirements shall include masons, helpers, shall be adequate as per the schedule of work
planned.
Page 6 of 8
Doc No : ATR-SPLL-CV-MST-0038
Rev. No : 00
Page 7 of 8
Doc No : ATR-SPLL-CV-MST-0038
Rev. No : 00
*******
Page 8 of 8
-
Q) LfI
............
ro 0
ON
Q) .....
:J 0
V')-
V') ~
I-
U
w
""""
o
ex;
Q.
a::
w
I- ~
Z
w
o
I-
:?!
(/)
.....
(/) <t
W I-
(/) Z
(/) w
<C C
~
- '"w
(/)
0::: ex;
ex;
-
<t ~ ~~
1:;
=..!i4
41...,
I- .... ~ IU
..... u~
9
~ ~ ~ ~~ ~
<t
• ...
..II:
o
::
~~------~------------~------------~------------~-----------4
Q)
e!
u
...
VI
o
o
i:i:
I
I
....
-
Q) U'I
.....,
ro 0
o N
Q) ....
::l 0
Vl-
Vl ~
If)
If)
I-
U
w
....,
o
a:
~
a::
w
.... ~
Z
w o
I-
:2 .....
en «
en
w I-
en Z
en w o
« C C'1
~ V)
-en
0::
w
a: If)
a:
-
«
I-
.....
« .....,
~
v
S
v
o
~I
I
«
I-
• -'
«
"d
~
~
I <+-<
o C/)
v -0
C/)
~c3
I
OJ LII
...... .-4
C1l 0
ON.......
OJ .-4
:::l 0
Vl .......
Vl ~
~
U
w
....
o
a:
a.
a:
w
t- ~
Z
w
o
t-
:i _,
en <
en
w t-
en Z
en w
« o
~ CI')
-en
~
w
a:
-a:
<t
_,
t-
<t
«
,_
• ...J
«
I
J
o:t
'+-
o
o:t
<1J
b.O
ro
c,
I-
U
w
~
o
a:: (!)
0. ..c:
.....
a::
w
I- ~
Z
W
o
I-
~3)N3(1b35NO) 9NIS\;l3~DNI
~
en .....
en «
w I-
en z
en w
< C
~ V)
en
-
tt:
w
a::
a::
-
«
Q)
:5
2
I- ro
..... :::l
""iii
« W
> II'l m
_DN3n03INOJ
N
~NIIV3.)NI
«
,_
• --'
«
Q)
:5
Q)
co:::l
I ""iii
w>
J
MIX DESIGN-DRY MIX
~ -
Shapoorji Pallonji Lanka (Pvt) Ltd A l I A I P
SCREED FOR APARMENTS
Code: C25DS(OPC)H360 Rev-01 I C2S(B(P)A(10/DS)C())
I
MIX DESIGN/PROPORTIONS -SCREED (FOR APARTMENTS)
Page 1 of I