PROFIBUS DP Communication Module

8.12.12 Data Set 95 - Reading the Statistics Data

ID
ByteBit Meaning Value range / [coding] Increment Comment
No.

Statistics
609 0 Motor current Imax 0 ... 797 % / [0 ... 255] 3.125 % 8-bit current
format
1 Reserved = 0
608 2 Last trigger current IA (%) 0 ... 1, 000 % / [0 ... 320] 3.125 %
4 Operating hours - device 0 ... 2 32 32
-1 s / [0 ... 2 -1] 1s
603 8 - 11 Number of starts motor right 0 ... 232-1 / [0 ... 232-1] 1
604 12 - 15 Number of starts motor left 0 ... 2 32-1 / [0 ... 232-1] 1
605 16 - 17 Number of overload trips 0 ... 65 ,535 / [0 ... 65, 535] 1
18 Reserved = 0
19 Reserved = 0
607 20 Motor current Imax (rms) 0 ... 20 ,000 A / [0 ... 2, 000 ,000] 0.01 A
606 24 Last trigger current IA (rms) 0 ... 20, 000 A / [0 ...2, 000 ,000] 0.01 A
602 28 Operating hours - motor 0 ... 2 32-1 s / [0 ... 232 -1] 1s
611 32 Operating hours - motor current 32 32
0 ... 2 -1 s / [0 ... 2 -1] 1s
18 ... 49.9 % x Ie(max)
612 36 Operating hours - motor current 0 ... 2 32-1 s / [0 ... 232 -1] 1s
50 ... 89.9 % x Ie(max)
613 40 Operating hours - motor current 0 ... 2 32-1 s / [0 ... 232 -1] 1s
90 ... 119.9 % x I e(max)
614 44 Operating hours - motor current 0 ... 2 32-1 s / [0 ... 232 -1] 1s
120 ... 1,000 % x Ie(max)
615 48 Reserved = 0
616 50 Number of contact block 0 ... 2 32-1 / [0 ... 232-1] 1
overload trips
617 52 Reserved = 0
618 54 Reserved = 0
619 56 Reserved = 0
620 60 Number of braking stops 0 ... 2 32-1 / [0 ... 232-1] 1
621 64 Number of starts - output 1 0 ... 232 32
-1 / [0 ... 2 -1] 1
622 68 Number of starts - output 2 0 ... 232 32
-1 / [0 ... 2 -1] 1
623 72 Number of starts - output 3 0 ... 232 32
-1 / [0 ... 2 -1] 1
624 76 Number of starts - output 4 0 ... 232 32
-1 / [0 ... 2 -1] 1
80 Reserved = 0
84 Reserved = 0
88 Reserved = 0
89 Reserved = 0

Table 8-28: Data set 95 - reading the statistics data