D e s c r i p t i o n

MPF MPF series filters are designed for return lines, and
are installed semi-immersed in a reservoir.
Continued Research & Development on both the fil-
ter bodies and the filter elements has resulted in a
MPF filters within this range are suitable for flow
rates up to 210 G.P.M.

MPF series are specifically designed for use in


product line with excellent pressure drop characteristics mobile applications, agricultural machinery and
combined with a high filtration efficiency. The high power units.
flow rate bypass valves are a standard feature with
this range of product.

INDICATOR ELECTRICAL
OPTIONS

VISUAL

COMBINED
SCREW-WASHER

New
COVER
absolute filter elements
independently tested REMOVAL HANDLE
in the following Institutes:

FULLY RESPONSIVE
BYPASS VALVE

PRESSURE DIE CAST


ALUMINIUM
È

MULTIPLE
FILTER ELEMENT
LENGTH OPTIONS

TANK FLANGE
O-RING
HIGH EFFICIENCY
ELEMENT WITH HIGH
DIRT HOLDING CAPACITY

NYLON BOWL

È
CAPTIVE
OPTIONAL
O-RING SEAL
EXTENSION
UNI EN ISO 9001 TUBE
N° 037/98

MPF 02030/7.99/USA 2
MP Filtri - Filtration technology

Filter element:

End caps: Support tube: Support frames:


Materials Nylon Galvanized steel Galvanized steel with
an epoxy coating
A Series
Inorganic microfiber MP Filter elements - Conform to the following
ISO standards
External support media ISO 2941 - Verification of collapse/burst resistance.
ISO 2942 - Verification of fabrication integrity and determination
of the first bubble point.
ISO 2943 - Verification of material compatibility with fluids.
ISO 3723 - Method for end load test.
ISO 3724 - Verification of flow fatigue characteristics.
Inner support
External wire mesh tube
ISO 3968 - Evaluation of pressure drop versus flow characteristics.
Internal wire mesh ISO 4572 - Multi-pass method for evaluating filtration performance.
Microfiber filtration media
Internal support media

Element material
Absolute filtration
A Series Contamination retention
Inorganic microfiber with acrylic support as per ISO 4572: Multi-pass test.

New improved ß ≥ 200 Dimensions for ß (µm) values Filtration ratios


filter elements with Filter ∆P

greater efficiency and elements ß≥2 ß ≥ 20 ß ≥ 75 ß ≥ 200 (psi)


ß2 ß10 ß20
(50%) (95%) (98,7%) (99,5%)
increased dirt holding
A03 – 2 2,4 3 20 > 10.000 > 10.000 100
capacity
A06 – 3 4,6 6 8 > 2.000 > 10.000 100
A10 3 6 7,8 10 1,5 ≥ 200 > 10.000 100
A25 13 19 22 25 – > 1,5 > 35 100
N.B. Other materials giving different degrees of filtration are available on request.

Filtering area Type MF 030-1 100-1 100-2 100-3 180-1 180-2 400-1 400-2 400-3 750-1

Filter elements A03/A06 52 97 155 268 666 1162 735 1075 1358 1767

“H”collapse ∆P = 145 PSI A10/A25 52 97 155 268 666 1162 735 1075 1358 1767
Values in sq in

Element material
Nominal filtration P Series M Series
Resin - impregnated paper Square wire mesh (filtration degree is defined
in microns by the maximum diameter of a
sphere corresponding to the mesh size)

Type MF 030-1 100-1 100-2 100-3 180-1 180-2 400-1 400-2 400-3 750-1
Filtering area P10/P25 63 158 258 294 620 1240 695 1015 1284 2085
Filter elements M25 45 71,3 113 194 310 698 374 545 689 1124
“N”collapse pressure ∆P = 45 PSI M60 45 71,3 113 194 310 698 310 465 595 969
M90 45 71,3 113 194 310 698 310 465 595 853
Values in sq in

3
MP Filtri - Specification

Filter body:
Materials
Head Seals
Pressure die cast aluminium A Series: Nitrile (Buna-N)
V Series: Viton
Cover
MPF 030-100 Nylon Bypass valve
MPF 180-750 Aluminium Nylon

Bowl Indicator
Nylon Brass
Working
temperature From -13° F to +230°F
For temperatures outside this range, please
consult our Sales and Network Organization
Pressure filter
body Maximum working pressure up to 45psi Fatigue test: a filter body subjected to
Test pressure: 72,5 psi pressure impulses from 0 to 45 psi will
Minimum burst pressure: 145 psi withstand 1.000.000 cycles
Collapse pressure
filter elements N Series 45 psi
H Series 145 psi

Bypass valve
Calibration pressure Bypass valve, differential opening pressure: B: 25 psi ± 10%

Compatibility
with fluids Filter head and bowls Filter elements
compatible for use with: As per ISO 2943; suitable for mineral oils
• mineral oils (types HH-HL-HM-HR-HV-HG as per ISO 6743/4)
(types HH-HL-HM-HR-HV-HG as per ISO 6743/4) synthetic fluids (A and M series only)
• water-based emulsions (types HS-HFDR-HFDS-HFDU as per ISO 6743/4)
(types HFAE-HFAS as per ISO 6743/4)
• synthetic fluids For water-based emulsions (types HFAE-HFAS
(types HS-HFDR-HFDS-HFDU as per ISO 6743/4) as per ISO 6743/4) and fluids other than
• water-glycol those mentioned, please consult our Sales
(types HFC as per ISO 6743/4) and Network Organization.
Ask for anodised version

Seals
A Series water - glycol
Nitrile (Buna-N) compatible with mineral oils (types HFC as per ISO 6743/4)
(types HH-HL-HM-HR-HV-HG as per ISO 6743/4) V Series
water - based emulsions Viton compatible with synthetic fluids
(types HFAE-HFAS as per ISO 6743/4) (types HS-HFDR-HFDS-HFDU as per ISO 6743/4)

Types of indicators
Operation:
All styles set to indicate an
element change at: 15 psi ± 10%

Visual indicator
VR Series Color coded pressure gauge
scale 0 – 30 psi

Electrical indicator
ER Series: Operational information:
Pressure switch with N.O. contacts Max voltage: 48 Vac 50÷60 Hz
EC Series: Max current: 0.5 A resistive, 0.2 A inductive.
Pressure switch with N.C. contacts

4
Selection & installation information

Filter elements A Series P Series M Series


types Absolute inorganic microfiber Nominal cellulose impregnated Metal mesh media, available in
filtration media, available in paper media, available in 10 25, 60, and 90 micron.
3, 6, 10 and 25 micron and 25 micron. Example - M25, M60 or M90.
Example - A03, A06, A10 or A25 Example - P10 or P25
Please refer to individual pressure drop cur ves to obtain filter element pressure drop information
The following filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter assembly (hous-
ing and filter element) pressure drop of 30% of the filter condition indicator 5.8 psi
3,93

2
1.22
ø 1.57 MPF SERIES 030 SIZE
Pg0.27
0,31
2,2

A/F 24 (mm)

2.2
0,86

1.69
MPF 030 Flow Weight
1.02

Filter Bowl Port size


A/F 14 rate lb
ø 2,59 assembly gpm 8 length BSP/NPT/SAE
(mm) 1/8” NPT **
3,38

1/8” NPT ø 1.18 A03 2,1


0,78

Housing pressure drop A06 3,1


ø 0,98 6 A10 5,5 1 1/2” 1.1
Ø 2,36
1/2” A25 7,9
∆p psi

ø 0,27
4
P10 7,9
2 * Flow rates suitable for 150 SUS fluid
** Weight including filter element
ø 3,54

0
A

0 7 14 21 28 35
Flow rate gpm Thread Type A

R 0,39
connections G1 1/2” BSP
G4 1/2” NPT
G7 SAE 8 - 3/4” - 16 UNF

1.22 MPF SERIES 100 SIZE


H1

2.65 ø 1.57
Pg0.27
A/F 24 (mm)
MPF 100 Weight
2.2

Flow
1.69
2.95

Filter Bowl Port size


0,47

1.02

rate lb
assembly length BSP/NPT/SAE
1.1

gpm *
A/F 14
(mm) 1/8” NPT
**
ø3.46 ø 1.18
A03 6,6
1/8” NPT
A06 7,9 1/2”
H

A10 9,2 1 2,2


A25 17,2
0,94

3/4”
P10 13,2
øB
Ø 3,15 A03 8,5
A06 10 3/4”

ø 0,33 Housing pressure drop A10 11,8 2 2,6


6 A25 33
1/2” 1”
3/4” P10 26,4
ø 4,52

4
∆p psi
A

A03 11,8
1” 3/4”
2 A06 14,5
R 0,39 0 A10 18,5 3 3,3
0 12 24 36 48 60
A25 39,6 1”
Flow rate gpm
P10 33
* Flow rates suitable for 150 SUS fluid
Lengths ** Weight including filter element
Type H H1 øB Thread Type A
1 3,9 4,7 1,1 connections G1 1/2” BSP
2 5,9 6,7 1,1 G2 3/4” BSP
3 8,8 9,8 1,7 G3 1” BSP
G4 1/2” NPT
G5 3/4” NPT
G6 1” NPT
G7 SAE 8 - 3/4” - 16 UNF
G8 SAE 12 - 1 1/16” - 12 UN
G9 SAE 16 - 1 5/16” - 12 UN
5
Selection
& installation information

Please refer to individual pressure drop cur ves to obtain filter element pressure drop information
The following filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter assembly (hous-
ing and filter element) pressure drop of 30% of the filter condition indicator 5.8 psi

1.22
MPF SERIES 180 SIZE
9,84

3.77 ø 1.57
Pg0.27

A/F24 (mm) MPF 180

2.2
Filter Flow rate Bowl

1.69
Port size Lenghth Weight
0,47

1.02
3,5

assembly gpm * length BSP/NPT/SAE H lb**


1.38

A/F14(mm)
1/8” NPT A03 30.4
ø5.07 1/8” NPT ø 1.18 A06 37
A10 48,8 1 1 1/4” 9,1 4,8
Housing pressure drop A25 79.2
H

P10 60.8
1,26

6 A03 52.8
A06 66
4
∆p psi

1/4” A10 79.3 2 1 1/4” 17,7 7,9


ø1.59
A25 92.5
ø4,33 2 P10 79.3
* Flow rates suitable for 150 SUS fluid
120° 0 ** Weight including filter element
ø6.89 0 20 40 60 80 100
Flow rate gpm
Thread Type A
connections G1 1 1/4” BSP
A

15 °
G4 1 1/4” NPT
R0,37
G7 SAE 20 - 1 5/8” - 12 UN
ø0.42

2.20
9.84

3.38 3.38
1.69 Pg 0.27 MPF SERIES 184 SIZE
A/F24(mm)
1/8” NPT

1.22

MPF 184
4.05

ø 1.18

Filter Flow rate Bowl Port size Lenghth Weight


0.43

assembly gpm * length BSP/NPT/SAE


1.69

H lb**
E A03 30.4
ø4.94 A06 37
A/F14(mm)
A10 48,8 1 1 1/4” 9,1 5,5
A25 79.2
1/8” NPT
9.05

P10 60.8
A03 52.8
1.26

1.34 ø 1.57
A06 66
A10 79.3 2 1 1/4” 17,7 8,6
A25 92.5
ø 1.59
P10 79.3
ø4.33 * Flow rates suitable for 150 SUS fluid
** Weight including filter element

90°
Thread Type A E
C
connections G1 1 1/4” BSP 1/8” BSP

45° G2 2 Ports 1 1/4” BSP 1/8” BSP


Port “1” Port “2” G4 1 1/4” NPT 1/8” NPT
B
A

G5 2 Ports 1 1/4” NPT 1/8” NPT


G7 SAE 20 - 1 5/8” - 12 UN 1/8” NPT
D

n°4 holes ø0.43


R 0.43 G8 2 Ports SAE 20 - 1 5/8” - 12 UN 1/8” NPT
ø6,26

Flange connections Housing pressure drop


6
Type A B C D E
4
∆p psi

F1 1 1/2” SAE 3000 PSI/M 2,75 1,406 M12 1/8” BSP 1/4”
F2 1 1/2” SAE 3000 PSI/UNC 2,75 1,406 1/2” UNC 1/8” NPT 2
F3 2 Ports 1 1/2” SAE 3000 PSI/M 2,75 1,406 M12 1/8” BSP
0
F4 2 Ports 1 1/2” SAE 3000 PSI/UNC 2,75 1,406 1/2” UNC 1/8” NPT 0 20 40 60 80 100
Flow rate gpm

6
Selection
& installation information

Please refer to individual pressure drop cur ves to obtain filter element pressure drop information
The following filter sizing recommendations are based using a mineral oil fluid at 150 SUS with a maximum total filter assembly (hous-
ing and filter element) pressure drop of 30% of the filter condition indicator 5.8 psi

MPF SERIES 400 SIZE


4.54 1.22
H1

ø 1.57
Pg0.27
MPF 400 Filter Flow rate Bowl Port size
Weight
3.87

A/F24 (mm)

2.2
lb

1.69
assembly gpm *
0.51

length BSP/NPT/SAE
1.02
1.51

A/F14(mm)
**
1/8” NPT A03 31,7
ø6.83
1/8” NPT ø 1.18 A06 39,6 1 1/4”
A10 45 1 6,6
H
1.73

A25 79,2
Housing pressure drop 1 1/2”
P10 59,4
1 1/2”
øB 6
1 1/4” A03 40,9
5.74
4 2” A06 52,8 1 1/2”
∆p psi

ø8.66
ø0.45 A10 63,4 2 7,7
2
R0.39 A25 120
0 2”
0 40 80 120 160 200 P10 90
30°
Flow rate gpm A03 52,8
A

90° A06 63.4


A10 79,2 3 2” 8,1
A25 132
P10 105,6
* Flow rates suitable for 150 SUS fluid
** Weight including filter element
Lengths Thread Type A
Type H H1 øB connections G1 1 1/4” BSP
1 7 7,87 2 G2 1 1/2” BSP
2 9,37 9,84 2,52 G3 2” BSP
3 11,33 12,2 2,52 G4 1 1/4” NPT
G5 1 1/2” NPT
A
G6 2” NPT
17,71

4,96 G7 SAE 20 - 1 5/8” - 12 UN


C

G8 SAE 24 - 1 7/8” - 12 UN
D

B
0,55
4,13

G9 SAE 32 - 2 1/2” - 12 UN
1,9

1.22
ø 6.83 ø 1.57 MPF SERIES 750 SIZE
Pg0.27

A/F24 (mm)
2.2
1.69

MPF 750 Flow Weight


1.02

Filter rate Bowl Port size lb


16.92

A/F14(mm) assembly gpm length BSP/NPT/SAE


1/8” NPT ø8.66 * **
1/8” NPT ø 1.18 ø0.45 A03 66
R0.39
A06 76,6
1.73

30° A10 99 1 2” 15.4


A

A25 165
ø2.52
90° P10 127
* Flow rates suitable for 150 SUS fluid
** Weight including filter element

Housing pressure drop Thread Type A

6
connections G1 2” BSP
G4 2” NPT
2”
∆p psi

4
G7 SAE 32 - 2 1/2” - 12 UN
2
Flange connections
0 Type A B C D
0 40 80 120 160 200
Flow rate gpm F1 2” SAE 3000 PSI/M 3.061 1.688 M12
7 F2 2” SAE 3000 PSI/UNC 3.061 1.688 1/2” UNC
Pressure drop information

General
Pressure drop versus flow rate curve information for both housing and filter elements is in accordance with ISO 3968

Filter assembly pressure drop - ∆p Total = ∆p Housing + ∆p Filter element

Housing pressure drop - The housing pressure drop is proportional to the fluid density

Filter element pressure drop - Filter element pressure drop is proportional to kinematic viscosity therefore always check the
fluid operating temperature and fluid type to obtain the working viscosity according to the following formula:

∆p1 Filter element = (working viscosity/brochure viscosity) x ∆p filter element

Brochure viscosity 150 SUS

Filter assembly sizing example


• Customer requires a 43 gpm filter assembly
• Mineral oil fluid: 317 SUS at 104°F
• A25 - 25 micron absolute filtration

Selection :
•Housing pressure drop - MPF 180 - 184 with 43 gpm ∆p = 0.6 psi (see curve on page 6)
•Filter element pressure drop (brochure viscosity) - MF 180.1.A25HB with 43 gpm ∆p = 1.95 psi (see curve on page 9)
•Filter element pressure drop (working viscosity) - With 317 SUS ∆p1 = 1.95 x (317/140) = 4.4 psi
•Filter assembly pressure drop ∆p Total = ∆p Housing + ∆p1 Filter element = 0.6 + 4.4 = 5 psi* { Acceptable pressure drop value,
as per our recommendations

Bypass valves pressure drop


The curves were obtained using a mineral oil with a density of 0.86
The ∆p varies proportionally to the density.

MPF 030 MPF 100


60 60
∆p psi

∆p psi

40 40

20 20

0 0
0 6 12 18 24 0 10 20 30 40
Flow rate gpm Flow rate gpm

MPF 180-184 MPF 400-750


60 60
∆p psi

∆p psi

40 40

20 20

0 0
0 20 40 60 80 0 40 80 120 160
Flow rate gpm Flow rate gpm

8
MF 030 - 1 P...N
Filter elements - N - ∆P 45 psi 15
P10

∆p psi
10
The curves were obtained using a mineral oil with a kinematic viscosity 150 SUS.
The ∆p varies proportionally to the fluid kinematic viscosity. 5 P25
For the metal mesh filter elements curves (M series), 0
please consult our Sales and Network Organization 0 6 12 18 24
Flow rate gpm
MF 100 - 1 P...N MF 100 - 2 P...N MF 100 - 3 P...N
15 P10 15 15
∆p psi

∆p psi

∆p psi
10 10 P10 10
P10
5 P25 5 5
P25 P25
0 0 0
0 10 20 30 40 0 10 20 30 40 0 10 20 30 40
Flow rate gpm Flow rate gpm Flow rate gpm
MF 180 - 1 P...N MF 180 - 2 P...N MF 400 - 1 P...N
15 15 15

P10
∆p psi

∆p psi

∆p psi
10 P10 10 P10 10

5 5 5
P25 P25 P25
0 0 0
0 20 40 60 80 0 30 60 90 120 0 30 60 90 120
Flow rate gpm Flow rate gpm Flow rate gpm
MF 400 - 2 P...N MF 400 - 3 P...N MF 750 - 1 P...N
15 15 15

P10
∆p psi

∆p psi

∆p psi
10 10 10 P10
P10
5 P25 5 P25 5 P25
0 0 0
0 40 80 120 160 0 40 80 120 160 0 50 100 150 200
Flow rate gpm Flow rate gpm Flow rate gpm

MF 030 - 1 A...H
Filter elements - H - ∆P 145 psi ∆p psi
15 A03 A06 A10
10 A25
The curves were obtained using a mineral oil with a kinematic viscosity of 150 SUS.
The ∆p varies proportionally to the fluid kinematic viscosity. 5

0
0 6 12 18 24
Flow rate gpm
MF 100 - 1 A...H MF 100 - 2 A...H
A06 A06 MF 100 - 3 A...H
15 A03 A10 15 A03 15 A03 A06
A10
A25
∆p psi

∆p psi

∆p psi

10 10 10 A10
5 5 A25 5 A25

0 0 0
0 10 20 30 40 0 10 20 30 40 0 10 20 30 40
Flow rate gpm Flow rate gpm Flow rate gpm

MF 180 - 1 A...H MF 180 - 2 A...H MF 400 - 1 A...H A06


15 A03 15 15 A03 A10
A06 A03
∆p psi

∆p psi

∆p psi

10 10 10
A10
A06 A25
5 A25 5 A10 5
* A25
0 0 0
0 20 40 60 80 0 30 60 90 120 0 30 60 90 120
Flow rate gpm Flow rate gpm Flow rate gpm
MF 400 - 2 A...H MF 400 - 3 A...H MF 750 - 1 A...H
15 A03 A06 15 A03 15 A03
A06 A06
A10
∆p psi

∆p psi

∆p psi

10 10 A10 10 A10
A25 A25
5 5 5 A25

0 0 0
0 40 80 120 160 0 40 80 120 160 0 50 100 150 200
Flow rate gpm Flow rate gpm Flow rate gpm

*Example: See page 8 9


Filter element replacement

The filter element has a handle on the top allowing easy


removal from the bowl.

The helical spring is utilized to secure the filter element


in its location.

Special application filters on request

Minimum Lengths
Extension tube option
MPF030-1 200mm / 7.87 in
HOW TO SPECIFY AN EXTENDED IN AN ASSEMBLY PART NUMBER
MPF100-1 200mm / 7.87 in
– Determine the “H”dimension in millimeters or inches (including the
tube) you will require MPF100-2 250mm / 9.84 in
– Divide this number by 10 and add the answer after a slash (/) at MPF100-3 330mm / 12.99 in
the end of the assembly par t number.
MPF180/184 340mm / 13.38 in
NOTE: The “H”dimension can only be specified in multiples of 10 MPF400-1 280mm / 11.02 in
millimeters
and it is subject to the minimum lengths listed below. MPF400-2 340mm / 13.38 in
Example: For a MPF1001AG4A10HBT filter assembly with an “H” MPF400-3 390mm / 15.35 in
dimension of 200
millimeters the final par t number would look like this: MPF750-1 530mm / 20.86 in
MPF1001AG4A10HBT/20

Filler plug Thread Wrench A/F (mm)


Filler plug: MPF 030-1 M33x1.5 34
Please note, when the T5 option is required, fill the ordering, MPF 100-1 M33x1.5 34
code with H instead of G option (see the example below) MPF 100-2 M33x1.5 34
Indicator option is not available when the filler plug is fitted (except
for MPF 184). MPF 100-3 M33x1.5 34
MPF 180-1 M33x1.5 34
Ordering code: MPF 180-2 M33x1.5 34
(See page 11) T5 MPF 184-1 SAE 12 27
MPF 184-2 SAE 12 27
Example: MPF 030 1 A H1 A10 NB/T5 MPF 400-1 M33x1.5 34
MPF 400-2 M33x1.5 34
MPF 400-3 M33x1.5 34
Applications MPF 750-1 M33x1.5 34

Example of application

10
Or dering infor mation

MPF /xx

Nominal sizes Filter condition indicator


030 T With plug (std)
100 VR Visual
180 ER Electrical: N.O. contacts
184 (use MF 180 filter element code) EC Electrical: N.C. contacts
400 T5 Filler plug (see page 10)
750 XX Exstension tube (see page 10)

Bowl lengths
MPF 030 = 1
MPF 100 = 1,2,3
MPF 180-184 = 1-2 Bypass valve
MPF 400 = 1,2,3
MPF 750 = 1 B Bypass 25 psi

Seals
A Nitrile (Buna-N)
V Viton
Seals (Filter elements)
B Nitrile (Buna - N)
Ports option V Viton
Type MPF 030 MPF 100 MPF 180 MPF 184 MPF 400 MPF 750

G1 1/2” BSP 1/2” BSP 1 1/4” BSP 1 1/4” BSP 1 1/4” BSP 2” BSP

2 Ports
G2 – 3/4” BSP – 1 1/2” BSP –
1 1/4” BSP

G3 – 1” BSP – – 2” BSP – Collapse pressure series


N 45 psi (P/M series)
G4 1/2” NPT 1/2” NPT 1 1/4” NPT 1 1/4” NPT 1 1/4” NPT 2” NPT H 145 psi (A series, only)

2 Ports
G5 – 3/4” NPT – 1 1/2” NPT –
1 1/4” NPT

G6 – 1” NPT – – 2” NPT –

G7 SAE 8 SAE 8 SAE 20 SAE 20 SAE 20 SAE 32


Filter elements N series
2 Ports
G8 – SAE 12 – SAE 24 – P10
P25 Resin-impregnated paper Bx ≥ 2
SAE 20

G9 – SAE 16 – – SAE 32 – M25


M60 Square wire mesh
1 1/2” SAE 2 SAE M90
F1 – – – 3000 PSI/M
– 3000 PSI/M
Filter elements H series
F2 – – – 1 1/2” SAE – 2 SAE
3000 PSI/UNC 3000 PSI/UNC A03
A06 Inorganic microfibre Bx ≥ 200
F3 – – – 2x1 1/2” SAE – – A10
3000 PSI/M A25
F4 – – – 2x1 1/2” SAE – –
3000 PSI/UNC

MF
Replacement element
MP Filtri - Filtration products will only be guaranteed if original MP Filtri replacement elements are used
Data hold in this pubblication are given only for indicative purposes. MP Filtri reserves to introduce modifications to describe items in every moment either for technical or commercial reasons. Copyright reserved.

11
®
Head Quarter :
MP FILTRI S.p.A. Italy
Via Matteotti, 2
20060 Pessano con Bornago (Milano) Italy
Tel. ++39.02/95703.1
Fax ++39.02/95741497-95740188
email: sales@mpfiltri.com
http://www.mpfiltri.com

GREAT BRITAIN
MP FILTRI U.K. Ltd.
Bour ton Industrial Park
Bour ton on the Water
Gloucestershire GL54 2HQ UK
Phone: 01451-822522
Fax: 01451-822282
email: sales@mpfiltri.co.uk
http://www.mpfiltri.co.uk

GERMANY
MP FILTRI D GmbH
Am Wasser turm 5
D-66265 Heusweiler/Holz
Phone: 06806/85022-0
Fax: 06806/85022-18
email: mpfiltrink@aol.com

U.S.A.:
MP FILTRI U.S.A. Inc.
1256C Oakbrook Drive - Norcross,
Georgia - U.S.A. 30093
Phone: 770-263-0090
Fax: 770-242-4069
email: mpusasales@aol.com

CANADA:
MP FILTRI CANADA Inc.
210 Jacob Keffer Parkway Concord,
Ontario Canada L4K 4W3
Phone: 905-303-1369
Fax: 905-303-7256
email: mail@mpfiltricanada.com
http://www.mpfiltricanada.com

You might also like