S TA N D A R D F E AT U R E S G L O B A L I N S TA L L AT I O N C A PA B I L I T Y - W O R L D W I D E T E C H N I C A L S E R V I C E
• Solid-state memory devices (for program and data) for
all essential (IMO-required) VDR functions.
• Extended recording of all data on internal hard drive
is standard.
- 30 days* of all video, audio and digital data
- up to 6 overwrite-protected 12-hr data sets can be 24/7 product
We offer a 24/7 product support
support line.
line.
saved on the internal hard drive
• Distributed single cable Ethernet & power technology Call us at + 1Email
709 368 4213 or email support@ruttertech.com.
sales@netwavesystems.com
reduces cabling and related costs by locating interface
modules close to sensors.
• Modular system components with small dimensions and
minimal weight for easy transport and installation.
• Integrated USB port with flash drive offers flexible
recording of current 24-hr data or download of recorded
or saved 12-hr data sets selected by date and time.
• Connected to a remote PC.**
• Download and playback software is included with every
system, along with free owner licenses.**
* May be less for more than IMO required data.
** Meets the new IMO Recommendation SN/Circ.246 and MSC.214(81), mandatory
from 1 July 2008, for a data output port and download/playback software.
D ATA S T O R A G E D ATA P L AY B A C K A N D
A N D R E T R I E VA L O P T I O N S D I S P L AY O P T I O N S
Standard data storage and retrieval functions go well Standard playback and display features are comprehensive
beyond IMO requirements and we offer the following and we offer the following additional options:
additional options: • The Advanced Graphic Analysis Module enables long-
• The Automatic Data Archiving Module provides for term trend analyses, simultaneous comparisons among
long-term archiving of the full data set, either by all data parameters and provides for extraction and
means of a remote PC or by a connected Remote transfer of the data to spreadsheets for further analyses
Storage Module. as required.
• The Multiple Video Display Capture option allows • The Real-Time Display Module provides a conning-like
the VDR to capture and record up to three additional
displays in addition to the single required main
real-time display of all recorded navigation data and
allows for real-time display of recorded images.
Compact Voyage Data Recorders that Deliver Performance, Reliability and Value
radar video. R U T T E R O F F I C E L O C AT I O N S
VDR-100G3/G3S
Diagnostics are available via any standard
communications channel, allowing for monitoring and
retrieval of data from anywhere in the world.
T E C H N I C A L F E AT U R E S R E L I A B L E V O YA G E D ATA R E C O R D E R S T H AT D E L I V E R E X C E P T I O N A L VA L U E
Data Processing Unit (DPU) NMEA Input Module IMO regulations for fitting simplified voyage RUTTER’S VDR AND SIMPLIFIED VDR SYSTEM
• houses Data Management Module, power supply, • 9 inputs are available with each module data recorder (S-VDR) on existing cargo vessels:
Power Control Module and battery back-up system • additional modules can be added • cargo vessels of 20,000 gross tonnage and upwards DATA PROCESSING UNIT (DPU)
• removable Operation and Alarm Unit (OAU) • for data in IEC 61162 (NMEA 0183) format constructed before 1 July 2002, at the first scheduled Remote Operation
dry-docking after 1 July 2006, but no later than and Alarm Unit (OAU) USB Flash Drive
• USB flash drive in closed compartment • for direct connection of AIS 1 July 2009. (Optional)
• compact (only 150mm x 457mm x 457mm) • accepts the outputs from Rutter Interfaces • cargo vessels of 3,000 gross tonnage and upwards,
• weighs only approximately 23kg but less than 20,000 gross tonnage constructed before
USB Flash Drive Data Storage
1 July 2002, at the first scheduled dry-docking after
VDR Data Socket • storage of saved or previous 24-hours of data 1 July 2007, but no later than 1 July 2010.
DATA
• for connection to external PC • simple control via Operation and Alarm Unit SOCKET
• standard Ethernet RJ45 socket • USB flash drive protected inside DPU Rutter Technologies provides a full family of marine-
• suitable for remote diagnostics and data transfer • flexible download of 12-hour data sets selected certified interfaces to accommodate all mandatory or
voluntary data recording requirements for any type CAPSULE
by date and time. Remote Storage Module
Final Recording Medium (FRM)
VDR-100G3/G3S
of ship.
• fixed or float-free capsules are available Operation and Alarm Unit (OAU)
Satellite Link
• compact lightweight designs • standard integration in DPU or remote mounting DataAnalog
(144mm x 144mm)
• easy to install • 8 inputs for analogue order and response signals RUTTER SOFTWARE:
• indicates the system status
The logical evolution of a proven technology. •
•
powered by Power Control Module
can be mounted 75m away from DPU
• allows users to perform basic system diagnostics DataDiscrete S-VDR VDR
• Real-Time Display
• Data Download
• simple user interface for recording and copying data • 24 inputs for status, alarm and control signals • Playback
Compact, flexible and reliable. Remote Storage Module (Optional) • 24 VDC Alarm output for remote alarm indication DataGyro DATA ACQUISITION UNIT (DAU)
• Diagnosis
• Modular “fit-anywhere” design, reducing retrofit cost and out-of-service time optional housing for interfaces 38
• Connection of remotely installed interface modules by single cables for Ethernet & power supply All dimensions are in millimetres. Products shown in approximate relative proportions. Dimensions and components subject to change without notice.
Float-Free Capsule