You are on page 1of 2

Date 03/12/2019.

Field Name: ABIGBORODO


PETINENT DATA: JACKET: 01 BARGE: SIRPI FJORD./CO/NAME : BENEK
TEL(FAX) CAPT/CO-MAN: FOLARIN

SINGLE DUAL
WELL NAME INITIAL FINAL FINAL INITIAL
PRESS

TREE SIZE 3-1/8 mod B


FTHP/FLP

TREE TYPE Vetco Gray 0psi 1520psi 1540psi 1000psi


SITHP

BASE MANAGER Clifford Odia CHP:A 0psi 0psi 0psi 0psi


BENEK TEAM DIGA PHILIP/ not ok ok
ONWUFUJU C LMV

ok not tested

WV

FLOWLINE PLUG VALVE UMV ok ok


CONTROL PILOT SETTING SV ok ok

POB 2 SCSSV
TEST
SDV ok not tested

START FINISH DESCRIPTION : Zonal Isolation


2215hrs 2240hrs Tested and greased Abigborodo Well AG-01 (Long String) UMV for 15mins and it was ok
2240hrs 2305hrs Tested and greased Abigborodo Well AG-01 (Long String) WV for 15mins and it was ok
2305hrs 2330hrs Tested and greased Abigborodo Well AG-01 (Long String) SDV for 15mins and it was ok

2330hrs 2355hrs Tested and greased Abigborodo Well AG-01 (Long String) SV for 15mins and it was ok
2355hrs 0040hrs Tested and greased Abigborodo Well AG-01 (Long String) LMV for 15mins and it built up pressure to
500psi, it was greased again and tested for 15mins and it built up to 120psi
0040hrs 0105hrs Tested and greased Abigborodo Well AG-01D (Short String) LMV for 15mins and it was ok
0105hrs 0130hrs Tested and greased Abigborodo Well AG-01D (Short String) UMV for 15mins and it was ok
0130hrs 0155hrs Tested and greased Abigborodo Well AG-01D (Short String) SV for 15mins and it was ok
0155hrs 0210hrs Tried testing Abigborodo Well AG -01D ( Short String) WV but. there was leakage from the bonnet
0210hrs 0220hrs Record initial SITHP = 0Psi & 1000psi for AG-01 and AG-01D respectively, Record initial CHP A
= 0Psi, CHP B=0psi
0220hrs 0330hrs Retrieved 3" BPV from Abigborodo Well AG-01 ( Long String)
0330hrs 0430hrs Retrieved 3" BPV from Abigborodo Well AG-01D (Short String)
0430hrs 0440hrs Record Final SITHP = 1520Psi & 1540psi for AG-01 and AG-01D respectively, Record Final CHP
A = 0Psi, CHP B=0psi
0440hrs 0500hrs House Keeping and Shutdown of Day's activity.
BENEK

Remarks
FINAL

bonnet of
Short
string WV
leaking

Otis

nd it was ok
d it was ok
d it was ok

it was ok
nd it built up pressure to

and it was ok
and it was ok
nd it was ok
as leakage from the bonnet
ly, Record initial CHP A

tively, Record Final CHP