You are on page 1of 20

RESULTS OF COMPRESSIVE STRENGTH TEST CONDUCTED ON CONCRETE CORE SAMPLES

Name of the work :- Maintanance


Construction to
of the
CC Road
Roadat
from Narsipatnam Tuni R&B road to Manyapuratla (Balance reach) of Nathavaram mandal Grant:
Estimate Cost: -
Date of Extraction:- 24/01/2020 Date of Testing

Correctio Corrected Corrected


Correctio
n factor comp. cylinder Equivalent
n factor
for dia as Strength of strength of cube
for L/D
per Measured core core strength of
ratio as
clause comp. (applying (equivalent the concrete
Actual Length per Mean
Dia of Length 8.4.1 of Strength of correction strength of (cylinder
Core Depth of core clause equivalent
Core / dia Mass in Density IS 516 Load core = max factor for cylinder strength ×
S.No. Identification of after 8.4.2 of cube
(D) ratio gms in gm/cc (Part 4) in KN load/ cross diameter to having L/D 5/4) as per
chainage Core(m capping IS 516 strength in
(mm) (L/D) 2018 section the ratio of 2) clause 8.4.2
m) (L) (Part 4) N/mm2
core dia area in measured applying of IS 516
2018
is 75 ± N/mm2 Comp. L/D (Part 4) 2018
5 =1.03 Strength correction Col
0.11(L/D
or <70 = Col 11 x factor Col 13x 1.25
)+0.78
1.06 Col 8 12 x Col 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Thimmapuram
1 At 43.80mts L/S

2 At 91.50mts Centre

2 At 150mts R/S

3 At 210mts Centre

Upparapalli
1 At 50mts L/S
2 At 100mts Centre

2 At 120mts Centre

3 At 150mts R/S

Asst Executive Engineer Dy. Executive Engineer


V&QC(PR), Narsipatnam V&QC(PR), Narsipatnam
ST CONDUCTED ON CONCRETE CORE SAMPLES

Date of Testing : 27/01/2020

(Invalid if (Average
the value is not less
less than than 85%
75% of grade of
Specified
grade of concrete)
grade of
concrete as as per
concrete
per clause clause
17.4.3 of 17.4.3 of
IS 456- IS 456-
2000 2000

16 17 18
RESULTS OF COMPRESSIVE STRENGTH TEST CONDUCTED ON CONCRETE CORE SAMPLES

Name of the work :- Construction of GSB at Grant:


Estimate Cost: - Rs 40.00lakhs

Date of Extraction:- 20/12/19 Date of Testing

Correctio Corrected Corrected


Correctio
n factor comp. cylinder Equivalent
n factor
for dia as Strength of strength of cube
for L/D
per Measured core core strength of
ratio as
clause comp. (applying (equivalent the concrete
Actual Length per Mean
Dia of Length 8.4.1 of Strength of correction strength of (cylinder
Core Depth of core clause equivalent
Core / dia Mass in Density IS 516 Load core = max factor for cylinder strength ×
S.No. Identification of after 8.4.2 of cube
(D) ratio gms in gm/cc (Part 4) in KN load/ cross diameter to having L/D 5/4) as per
chainage Core(m capping IS 516 strength in
(mm) (L/D) 2018 section the ratio of 2) clause 8.4.2
m) (L) (Part 4) N/mm2
core dia area in measured applying of IS 516
2018
is 75 ± N/mm2 Comp. L/D (Part 4) 2018
5 =1.03 Strength correction Col
0.11(L/D
or <70 = Col 11 x factor Col 13x 1.25
)+0.78
1.06 Col 8 12 x Col 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

Rajupeta
1 F2 footing sample 1

2 F2 footing sample 2

3 F2 footing sample 3

Nagulapalli -1
4 F2 footing sample 1

5 F2 footing sample 2

6 F2 footing sample 3

Asst Executive Engineer Dy. Executive Engineer


V&QC(PR), Narsipatnam V&QC(PR), Narsipatnam
ST CONDUCTED ON CONCRETE CORE SAMPLES

MGNREGS

Date of Testing : 27/12/19

(Invalid if (Average
the value is not less
less than than 85%
75% of grade of
Specified
grade of concrete)
grade of
concrete as as per
concrete
per clause clause
17.4.3 of 17.4.3 of
IS 456- IS 456-
2000 2000

16 17 18
RESULTS OF COMPRESSIVE STRENGTH TEST CONDUCTED ON CONCRETE CORE SAMPLES

Name of the work :-


Estimate Cost: -

Date of Extraction:-

Correctio Corrected Corrected


Correctio
n factor comp. cylinder Equivalent
n factor
for dia as Strength of strength of cube
for L/D
per Measured core core strength of
ratio as
clause comp. (applying (equivalent the concrete
Actual Length per
Dia of Length 8.4.1 of Strength of correction strength of (cylinder
Depth of core clause
Core Identification Core / dia Mass in Density IS 516 Load core = max factor for cylinder strength ×
S.No. of after 8.4.2 of
chainage (D) ratio gms in gm/cc (Part 4) in KN load/ cross diameter to having L/D 5/4) as per
Core(m capping IS 516
(mm) (L/D) 2018 section the ratio of 2) clause 8.4.2
m) (L) (Part 4)
core dia area in measured applying of IS 516
2018
is 75 ± N/mm2 Comp. L/D (Part 4) 2018
5 =1.03 Strength correction Col
0.11(L/D
or <70 = Col 11 x factor Col 13x 1.25
)+0.78
1.06 Col 8 12 x Col 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14

5
6

Asst Executive Engineer Dy. Executive Engineer


V&QC(PR), Narsipatnam V&QC(PR), Narsipatnam
TEST CONDUCTED ON CONCRETE CORE SAMPLES

Grant:

Date of Testing :

(Invalid
(Averag
if the
e not
value is
less than
less than
Mean 85%
75% of
equivale Specifie grade of
grade of
nt cube d grade concrete
concrete
strength of ) as per
as per
in concrete clause
clause
N/mm2 17.4.3
17.4.3
of IS
of IS
456-
456-
2000
2000

15 16 17 18
RESULTS OF COMPRESSIVE STRENGTH TEST CONDUCTED ON CONCRETE CORE SAMPLES

Name of the work :- Maintanance


Construction to
of the
CC Road
Roadat
from Narsipatnam Tuni R&B road to Manyapuratla (Balance reach) of Nathavaram mandal Grant:

Estimate Cost: - Rs 21.00lakhs

Date of Extraction:- 19/12/19 Date of Testing

Correctio Corrected Corrected


Correctio
n factor comp. cylinder Equivalent
n factor
for dia as Strength of strength of cube
for L/D
per Measured core core strength of
ratio as
clause comp. (applying (equivalent the concrete
Actual Length per Mean
Dia of Length 8.4.1 of Strength of correction strength of (cylinder
Core Depth of core clause equivalent
Core / dia Mass in Density IS 516 Load core = max factor for cylinder strength ×
S.No. Identification of after 8.4.2 of cube
(D) ratio gms in gm/cc (Part 4) in KN load/ cross diameter to having L/D 5/4) as per
chainage Core(m capping IS 516 strength in
(mm) (L/D) 2018 section the ratio of 2) clause 8.4.2
m) (L) (Part 4) N/mm2
core dia area in measured applying of IS 516
2018
is 75 ± N/mm2 Comp. L/D (Part 4) 2018
5 =1.03 Strength correction Col
0.11(L/D
or <70 = Col 11 x factor Col 13x 1.25
)+0.78
1.06 Col 8 12 x Col 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

1 At 50mts L/S 104 197 115 1.10577 3775 3.858 1 0.902 142.5 16.77 16.77 15.12 18.90

2 At 50mts Centre 104 205 115 1.10577 4210 4.302 1 0.902 191.0 22.48 22.48 20.26 25.33
20.21

3 At 50mts Centre 104 205 115 1.10577 4210 4.302 1 0.902 123.7 14.56 14.56 13.12 16.41
1 At 43.80mts L/S 104 129 115 1.10577 3775 3.858 1 0.902 236.3 27.81 27.81 25.07 31.34

2 At 91.50mts Centre 104 130 115 1.10577 4210 4.302 1 0.902 178.5 21.00 21.00 18.94 23.67

28.51
2 At 150mts R/S 104 127 115 1.10577 4210 4.302 1 0.902 235.0 27.65 27.65 24.93 31.17

3 At 210mts Centre 104 126 115 1.10577 4210 4.302 1 0.902 210.0 24.71 24.71 22.28 27.85

1 At 50mts L/S 104 197 115 1.10577 3775 3.858 1 0.902 158.0 18.59 18.59 16.76 20.95

2 At 100mts Centre 104 205 115 1.10577 4210 4.302 1 0.902 176.0 20.71 20.71 18.67 23.34

23.87
2 At 120mts Centre 104 205 115 1.10577 4210 4.302 1 0.902 176.0 20.71 20.71 18.67 23.34

3 At 150mts R/S 104 205 115 1.10577 4210 4.302 1 0.902 210.0 24.71 24.71 22.28 27.85

Asst Executive Engineer Dy. Executive Engineer


V&QC(PR), Narsipatnam V&QC(PR), Narsipatnam
ST CONDUCTED ON CONCRETE CORE SAMPLES

PMGSY MTC (2018-19)

Date of Testing : 27/12/19

(Invalid if (Average
the value is not less
less than than 85%
75% of grade of
Specified
grade of concrete)
grade of
concrete as as per
concrete
per clause clause
17.4.3 of 17.4.3 of
IS 456- IS 456-
2000 2000

16 17 18

20.00 15.00 17.00


30.00 22.50 25.50

30.00 22.50 25.50


RESULTS OF COMPRESSIVE STRENGTH TEST CONDUCTED ON CONCRETE CORE SAMPLES

Name of the work :- Construction of GSB at Grant:


Estimate Cost: - Rs 40.00lakhs

Date of Extraction:- 12/12/19 Date of Testing

Correctio Corrected Corrected


Correctio
n factor comp. cylinder Equivalent
n factor
for dia as Strength of strength of cube
for L/D
per Measured core core strength of
ratio as
clause comp. (applying (equivalent the concrete
Actual Length per Mean
Dia of Length 8.4.1 of Strength of correction strength of (cylinder
Core Depth of core clause equivalent
Core / dia Mass in Density IS 516 Load core = max factor for cylinder strength ×
S.No. Identification of after 8.4.2 of cube
(D) ratio gms in gm/cc (Part 4) in KN load/ cross diameter to having L/D 5/4) as per
chainage Core(m capping IS 516 strength in
(mm) (L/D) 2018 section the ratio of 2) clause 8.4.2
m) (L) (Part 4) N/mm2
core dia area in measured applying of IS 516
2018
is 75 ± N/mm2 Comp. L/D (Part 4) 2018
5 =1.03 Strength correction Col
0.11(L/D
or <70 = Col 11 x factor Col 13x 1.25
)+0.78
1.06 Col 8 12 x Col 9

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

1 F2 footing sample 1 69 120 110 1.5942 1022 2.480 1.06 0.955 66.5 17.78 18.84 18.00 22.50

2 F2 footing sample 2 69 117 113 1.63768 866 2.046 1.06 0.960 75.0 20.05 21.25 20.41 25.51
26.21

3 F2 footing sample 3 69 114 113 1.64 765 1.807 1.06 0.960 90.0 24.06 25.50 24.49 30.61
1 F2 footing sample 1 69 120 110 1.5942 1007.2 2.444 1.06 0.955 66.5 17.78 18.84 18.00 22.50

2 F2 footing sample 2 69 117 113 1.63768 1043 2.464 1.06 0.960 78.0 20.85 22.10 21.22 26.53
27.11

3 F2 footing sample 3 69 114 113 1.64 1045.3 2.470 1.06 0.960 95.0 25.40 26.92 25.85 32.31

4 F2 footing sample 1 69 120 110 1.5942 1036.3 2.515 1.06 0.955 99.3 26.55 28.14 26.88 33.60

5 F2 footing sample 2 69 117 112 1.62319 1070.9 2.553 1.06 0.959 90.2 24.11 25.56 24.50 30.62
32.20

6 F2 footing sample 3 69 114 114 1.65 1109.5 2.598 1.06 0.962 95.0 25.40 26.92 25.89 32.36

Asst Executive Engineer Dy. Executive Engineer


V&QC(PR), Narsipatnam V&QC(PR), Narsipatnam
ST CONDUCTED ON CONCRETE CORE SAMPLES

MGNREGS

Date of Testing : 16/12/19

(Invalid if (Average
the value is not less
less than than 85%
75% of grade of
Specified
grade of concrete)
grade of
concrete as as per
concrete
per clause clause
17.4.3 of 17.4.3 of
IS 456- IS 456-
2000 2000

16 17 18

30.00 22.50 25.50


30.00 22.50 25.50

30.00 22.50 25.50