Parameters Setting

BSTXPWR (UL) = 42
BSTXPWR (OL) = 40
LOL= 115
LOL HYST= 3
FBOFFS= 8
Cuurent Serving RxLev (dBm) = -70 <------- Fill in the current RxLev / Estimated RxLev

UL to OL

Condition: L <= LOL - LOLHYTST


where, L = BSTXPWR - RxLev

Condition RxLev (dBm) = -70

MS should be in: UL
Description: It mean, if the MS current RxLev is BETTER than -70

OL to UL

Condition: L >= LOL + LOLHYTST


where, L = BSTXPWR - [ RxLev + FBOFFS]

Condition RxLev (dBm) = -86

MS should be in: OL
Description: It mean, if the MS current RxLev is WORST than -86
, then the MS will HO from UL to OL.

, then the MS will HO from OL to UL.