You are on page 1of 16

Project No.

: GL-GEO-1920126

PROPOSED RESIDENTIAL BUILDING AT NO. 11 & 12, BEHIND SRI


KRISHNA TEMPLE, DODDABOMMASANDRA, VIDYARANYAPURA POST,
BANGALORE

GEOTECHNICAL ENGINEERING REPORT

Client:
Sri Sai Builders, Bangalore

January 2020

Geotechnical Investigation By:

ISO 9001:2015 Certified Company


#41, Sri Sri Venkatadri, V. Nagenahalli Main Road,
R.T. Nagar Post, Bangalore-560032
Ph: 080-79624558, Email: geologicsbang@gmail.com

▪SOIL INVESTIGATION ▪SLOPE PROTECTION▪GROUTING▪GROUND ANCHORS▪PILE FOUNDATION▪GROUND IMPROVEMENT ▪ NON-DESTRUCTIVE


TESTING ▪SOIL RESISTIVITY TEST
Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

To,
Sri Sai Builders, Bangalore.

22nd January 2020


Project No. GL-GEO-1920124

Subject: Geotechnical Investigation Report


Project: Proposed Residential Building at No. 11 & 12, Behind Sri Krishna Temple, Doddabommasandra,
Vidyaranyapura Post, Bangalore

GEOLOGICS is pleased to present the attached geotechnical for the above project. The purpose of our
investigation was to explore and evaluate the subsurface conditions at various locations on the site to develop
geotechnical engineering recommendations for project design and construction.

Recommendations regarding the geotechnical aspects of project design and construction are presented in the
following report. Recommendations provided herein are contingent on the provisions outlined in the Limitations
section of this report. The project Owner/Designer/Consultant should become familiar with these provisions to
assess further involvement by GEOLOGICS and other potential impacts to the proposed project.

We appreciate the opportunity of providing our services for this project. If you have questions regarding this report
or if we may be of further assistance, please contact the undersigned.

Sincerely,

GEOLOGICS,

Prepared by Approved By

__________________________ __________________________

| Page 1 of 7
Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

Document history and status

Issue Revision Checked &


Date Document/revision Type Prepared By
No. No. Approved By

1 0 22/01/2020 Engineering Report – Final KSN MSR

| Page 2 of 7
Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

Table of Contents

1) INTRODUCTION .......................................................................................................................................4

2) PROJECT INFORMATION ..........................................................................................................................4

3) SITE INVESTIGATION ...............................................................................................................................4

3.1. EXPLORATORY BOREHOLES .................................................................................................................4

4) LABORATORY TESTING ............................................................................................................................5

5) SUBSURFACE CONDITIONS ......................................................................................................................5

5.1. TYPICAL PROFILE .................................................................................................................................5

6) GROUND WATER TABLE ..........................................................................................................................6

7) RECOMMENDATIONS ..............................................................................................................................6

7.1. SHALLOW FOUNDATION - OPEN FOUNDATION ...................................................................................6

7.1.1. ADDITIONAL RECOMMENDATIONS..................................................................................................6

8) REPORT LIMITATIONS..............................................................................................................................7

APPENDICES

APPENDIX A Testing Location Plan

APPENDIX B Borehole Logs

APPENDIX C Summary and Discussions on laboratory test results

| Page 3 of 7
Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

1) INTRODUCTION

The Geotechnical Engineering Report has been completed for the Proposed Residential Building at No. 11
& 12, Behind Sri Krishna Temple, Doddabommasandra, Vidyaranyapura Post, Bangalore. The scope of
work involved drilling of 03 Boreholes designated as BH-01 through BH-03 to a maximum depth of 6.0m or
refusal whichever is earlier below the existing ground surface as per project requirement.

The purpose of this Geotechnical Investigation work is to provide information and geotechnical engineering
recommendation as described below:

 To determine the nature, depth and  To assess founding conditions for the
extent of the different soils underlying construction of the facility
the site  To comment on shallow groundwater
 To determine the engineering or seepage, if any, and
properties of the soils  To identify any other geotechnical
 To determine if the soil materials are aspects that may be relevant to the
suitable for construction purposes construction of the facility.

Boring location plan is presented in Appendix – A, borehole logs are presented in Appendix – B and
summary of laboratory test results are presented in Appendix – C.

2) PROJECT INFORMATION
Site Layout Refer Appendix – A, Tests Location Plan
Site Location Doddabommasandra, Vidyaranyapura Post, Bangalore
Structure Details Residential Building; No. of floors: G+4; Basement – No basement
Existing Structures Nil
Current Ground Cover Filled up soil Site Condition Not excavated

3) SITE INVESTIGATION

3.1. EXPLORATORY BOREHOLES

The field work for the current investigation was carried out on 17th January 2020. Altogether 03 boreholes
were drilled in locations provided by the client to investigate the subsurface in the planned development.
The locations of all the drilled boreholes were identified and marked on the site by GEOLOGICS as per the
drawing provided by Client. Drilling was performed using manual auger method. Field test data and
observations of all boreholes are presented in Appendix B.

During drilling of boreholes, Standard Penetration Tests; SPT were conducted in accordance with IS 2131 –
1981. The test uses a thick-walled sample tube, with an outside diameter of 50 mm and an inside diameter

| Introduction Page 4 of 7
Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

of 35 mm, and a length of around 650 mm. This is driven into the ground at the bottom of a borehole by
blows from a slide hammer with a weight of 63.5 kg falling through 760 mm. The sample tube is driven 150
mm into the ground and then the number of blows needed for the tube to penetrate each 150 mm up to a
depth of 450 mm is recorded. The sum of the number of blows required for the second and third 150mm of
penetration is termed the "standard penetration resistance" or the "N-value". In cases where 50 blows are
insufficient to advance it through a 150 mm (In a very dense and/or cemented soil layers), the penetration
after 50 blows is recorded. The blow count provides an indication of the density of the ground, and it is
used in many empirical geotechnical engineering formulae.

SPT was performed wherever the soil conditions are appropriate for SPT and the N-values are reported.
Disturbed SPT and bulk samples collected during drilling were retained in sealed, labeled plastic bags.
Relatively undisturbed soil samples, if available, were taken from cohesive soils using Shelby tube samplers,
later transported to our laboratory for further sample descriptions and determination of engineering
properties.

4) LABORATORY TESTING

After classification and carrying out the geological description on the obtained samples, a laboratory tests
program was issued; this program contained the required tests on selected samples to determine the
physical and mechanical properties of the ground materials. The tests were performed per the relevant
parts of Indian Standards as follows.
Table 1.0: Tests and reference standards
Water content IS 2720: Part 2: 1973 Free Swell Index IS 2720: Part 40
Grain Size Analysis IS 2720: Part 4: 1985 Direct shear test IS 2720: Part 13
Liquid and Plastic Limit IS 2720: Part 5: 1985 Specific Gravity of soil IS 2720: Part III-2

The summary of Laboratory tests and laboratory reports are presented in Appendix C.

5) SUBSURFACE CONDITIONS

5.1. TYPICAL PROFILE

The boreholes drilled shows that there are general similarities and continuities of the subsurface materials
with local variations. Filled up soil was observed from GL till 1.5/3.0m bgl followed by Very stiff to hard
sandy, SILT/CLAY till the termination depth of the boreholes. The boreholes were terminated at a depth of
6.0m bgl as per project specification. The standard penetration N-Values were varying from 5 to 60.

| Laboratory Testing Page 5 of 7


Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

6) GROUND WATER TABLE

The boreholes were monitored to determine the presence of groundwater/seepage water after 24 hours of
completion of borehole. At the time of field investigations, GWT/seepage water was not encountered in
any of the drilled boreholes within the exploration depth. However, during some periods of the year,
GWT/seepage water may be encountered. Fluctuations in ground water levels/seepage water are affected
by the variations in the amount of rainfall, runoff, evaporation and other hydrological factors not apparent
at the time of drilling. Longer monitoring would be required to evaluate long term groundwater conditions.
7) RECOMMENDATIONS

7.1. SHALLOW FOUNDATION - OPEN FOUNDATION

It is recommended to adopt shallow foundation for the proposed structure. The minimum depth of
foundation shall be 2.0m bgl or below filled up soil whichever is deeper. Table below provides the
bearing capacity parameters for design of foundations of size up to 3.0m. The estimated settlements
would be of the order of 25mm for square/ strip footings.
Table 2.0: Bearing Capacity Parameters – Isolated Footings
Borehole No. All Boreholes
Depth of Foundation 2.0m bgl 2.5m bgl 3.0m bgl
qa = Net Allowable SBC in kN/m2 170 185 210
Depth of GWT in m Nil
Width of foundation in m Up to 3.0m
Permissible settlement in mm 25mm
Note:
1. Bgl – below ground level,

7.1.1. ADDITIONAL RECOMMENDATIONS

1. The foundation shall rest on natural soil only. The foundation shall not be placed on filled up soil under any
circumstances.

2. If filled up soil is encountered at the proposed founding level, the same shall be removed till natural soil level
and replace with granular fill and compacted properly.

3. Due to presence of sandy SILT/CLAY stratum, accumulation of water in open excavation due to seepage or
rainfall can result in slush formation and may weaken the exposed stratum. In such a situation, it is
recommended to remove the slush completely till hard/firm stratum and a soling layer of 0.30m below
foundation level shall be provided. The soling shall be immediately covered PCC to prevent further weakening
of stratum. The soling layer shall be done using 40mm down size aggregates by removing loose soil completely
and by placing the larger stones first and the gaps shall be filled by smaller stones. The interstices shall then be
firmly packed with sand of 100 mm thickness or by flooding a mixture of sand & water or water cement slurry.

| Ground Water Table Page 6 of 7


Proposed Residential Building ▪ Doddabommasandra, Bangalore ▪ Project No. GL-GEO-1920126

4. For shallow foundations, when excavating to foundation level care should be taken not to disturb the
underlying strata. Any disturbed material, made ground or “soft spots” encountered at foundation level
should be removed and replaced with properly compacted engineering fill. Prior to foundation
construction, the soil at foundation level should be compacted to 95% of maximum dry density as
determined from a modified Proctor test. The compacted surface should then be protected by
immediately covering with a layer of concrete blinding.

5. In case any change in strata is observed during foundation excavation, the same shall be brought to the
notice of Geotechnical Consultant for the review of recommendations.

8) REPORT LIMITATIONS

This report is based on local experience and the findings at the exploratory locations. If different subsoil
conditions are encountered, the same may be brought to our notice and recommendations submitted
herein will be reviewed and revised as required. This report has been prepared for the exclusive use of the
client and their approved agents for specified application to this project. It has been prepared in
accordance with generally accepted soil and foundation engineering practices.

| Report Limitations Page 7 of 7


APPENDIX – A
Test Location Plan
APPENDIX – B
Borehole Logs
Drilling Method: Manual Auger Method
Date: 17/01/2020; Borehole Diameter: 150mm

BH-01: Existing Ground Level

DS 0.50

A
SPT(1.0-1.5m )=5/8/10=18 1.00 1.00

Filled up soil
A
1.50

2.00
A A, Filling

SPT(2.5-3.0m )=10/12/18=30 2.50


U, Silt

S, Sand 3.00

T, Clay

Special sam ple


SPT(4.0-4.5m )=15/17/18=35 4.00 4.00

5.00

SPT(5.5-6.0m )=20/24/26=50 5.50

Brownish to yellowish brown


U+S,t sandy SILT/CLAY
6.00 Very stiff to hard 6.00

BH Terminated at 6.0m below existing ground level


Maximum Exploration Depth; Water table not encountered

GEOLOGICS
#41, Sri Sri Venkatadri, V.Nagenahalli Main Road, RT Nagar, Bangalore
Scale 1:35 Title: Proposed Residential Development at Doddabommasandra, Bangalore
File: BH-01 Date: 22/01/2020
Page No.: Project: GL-GEO-1920126
Drilling Method: Manual Auger Method
Date: 17/01/2020; Borehole Diameter: 150mm

BH-02: Existing Ground Level

DS 0.50

SPT(1.0-1.5m )=2/2/3=5 1.00 1.00

2.00
A A, Filling

SPT(2.5-3.0m )=20/22/25=47 2.50


U, Silt
Filled up soil
A
S, Sand 3.00 3.00

T, Clay

Special sam ple


SPT(4.0-4.5m )=16/17/19=36 4.00 4.00

5.00

SPT(5.5-6.0m )=20/24/28=32 5.50

Brownish to yellowish brown


U+S,t sandy SILT/CLAY
6.00 Very stiff to hard 6.00

BH Terminated at 6.0m below existing ground level


Maximum Exploration Depthl; Water table not encountered

GEOLOGICS
#41, Sri Sri Venkatadri, V.Nagenahalli Main Road, RT Nagar, Bangalore
Scale 1:35 Title: Proposed Residential Development at Doddabommasandra, Bangalore
File: BH-02 Date: 22/01/2020
Page No.: Project: GL-GEO-1920126
Drilling Method: Manual Auger Method
Date: 17/01/2020; Borehole Diameter: 150mm

BH-03: Existing Ground Level

DS 0.50

A
SPT(1.0-1.5m )=8/9/11=20 1.00 1.00

Filled up soil
A
1.50

2.00
A A, Filling

SPT(2.5-3.0m )=14/11/17=28 2.50


U, Silt

S, Sand 3.00

T, Clay

Special sam ple


SPT(4.0-4.5m )=16/18/21=39 4.00 4.00

5.00

SPT(5.5-6.0m )=26/28/32=60 5.50

Brownish to yellowish brown


U+S,t sandy SILT/CLAY
6.00 Very stiff to hard 6.00

BH Terminated at 6.0m below existing ground level


Maximum Exploration Depth; Water table not encountered

GEOLOGICS
#41, Sri Sri Venkatadri, V.Nagenahalli Main Road, RT Nagar, Bangalore
Scale 1:35 Title: Proposed Residential Development at Doddabommasandra, Bangalore
File: BH-03 Date: 22/01/2020
Page No.: Project: GL-GEO-1920126
APPENDIX – C
Summary of Laboratory Test Results
Summary of Lab Test Results Boreholes

Proposed Residential Development at No. 11 & 12, Behind Sri Krishna Temple, Doddabommasandra,
Project:
Vidyaranyapura Post, Bangalore
Client: Sri Sai Builders Contractor -
Project No.: GL-GEO-1920126
Shear
Natural Moisture

Specific Gravity
Particle Size Analysis Atterberg Limits
Content (%)
Parameters

Cohesion, C
Liquid Limit
Sl. Depth Boulders %

Silt/Clay %
Cobbles %

Angle, phi
Gravel %

FSI
BH no.

Friction
Limit %
Sand %

Plastic

in kPa

in deg
No in m

PI
%
3.0 13.0 0.0 0.0 5.0 59.0 36.0 37.9 25.9 12.0 5 31 25 2.64
1 BH-01
6.0 12.4 0.0 0.0 7.7 41.2 51.1 40.8 25.4 15.4 - - - -
4.5 23.6 0.0 0.0 7.8 30.0 62.2 44.5 27.2 17.3 - - - -
2 BH-02
6.0 13.1 0.0 0.0 1.0 44.5 54.5 41.3 24.7 16.5 - - - -
4.5 18.8 0.0 0.0 1.0 38.2 60.8 36.8 24.7 12.2 7 28 25 2.61
3 BH-03
6.0 13.5 0.0 0.0 12.0 44.7 43.4 - - - - - - -

Discussion of Laboratory Test Results


MIN MAX
1. Natural Moisture Content is varying betwe 12.4 & 23.6

2. Grain Size Analysis General Classification of soil


a. Sand % Varying between 30.0 & 59.0
Silty/clayey SAND or sandy SILT/CLAY
b. Silt/clay % is varying between 36.0 & 62.2
c. Gravel % is varying between 1.0 & 12.0

3. Atterberg Limits SILT/CLAY Classification


a. Liquid Limit is varying between 36.8 & 44.5 SILT of low to intermediate Compressibility
b. Plasticity Index is varying between 12.0 & 17.3 characteristic

Swelling Characteristics
4. Free swell index is Varying between 25.0 & 25.0 Negligible swelling type SILT/CLAY

1 of 1

You might also like