The warranty period for this series is one year from the date of shipment ,please
refer to your invoice or shipping documents to determine appropriate
warranty dates. Hvhipot corporation warrants to the original purchaser
that this product will be free from defects in material and workmanship
under normal use.Thoughout the warranty period, provide that such
defects ars not determined by Hvhipot to have been caused by abuse,
misuse, alteration,improper installation ,neglect or adverse environmental
condition.Hvhipot is limited solely to repair or replacement of this
instrument during the warranty period.
Maintenance
To keep the instrument clean, wipe the case with a damp cloth and
detergent. Do not use abrasives or solvents.
Applications
Features --------------------------------------------------- 2
• Harmful space charges are not injected into the cable insulation.
Ⅰ . Controller Panel
1mF @ Up to 5.5uF at
GDVLF-30/1.1 30kV 36×25×21 6 33×18×39 25
reduced frequency
1mF @ Up to 5.5uF at
GDVLF-40/1.1 40kV 36×25×21 6 33×18×39 28
reduced frequency
1mF @ Up to 5uF at
GDVLF-50/1.1 50kV 36×25×21 6 37×24×39 45
reduced frequency
>> Operating Ti ps
2. When using it, the capacitance of the sample should not exceed the rated capacity
of the instrument. The overlow capacitance of the sample will affect the output wave
form. If the capacitance is less than 0.05µF, the instrument cannot output normally.
3. When using it, it is prohibited to boost voltage without load, or to connect with
resistive load.
rated voltage is less than or equal to Very low frequency of 50kV or when
The user should adopt method of connection in series when the rated
Parameter Setting after the power of equipment is put on). The mothod
After conneting the wiring of all the circuits, the power switch can be put
on. The instrument will automatically enter into the limit setting interface
Caution:
• The power should be shut-down when on wiring, removal of lines or
the fuse tube ,because the power socket is provided with fuse tube.
Figure 1
On limit setting interface as shown in figure 1, the user can set frequency,
test time and voltage, overcurrent protection on high-voltage side and
overvoltage protection value according to test requirement. The methods
are as follows:
a. Click “Selection” key, and the special selective box can be shifted
among the parameters in cycle. The selected parameters can be modified
through “data modification”(change) key.
b. Click “Change” key and the parameter selected by the special box can
be modified in cycle.
c. Click “Return” key, the instrument will enter into voltage boost standby
interface as shown in figure 2 .
a. Click “Boost” key, the instrument will enter into automatic boost
procedure.
b. Click “Setting” key, the instrument will return to set limit sub-interface
as shown in figure 2 to re-modify parameter.
c. Click “Check” key to check the test data in the last nine times.
Figure 2
Click “Boost” key as shown in Figure 2, the instrument will enter into
boost test under microcomputer control according to the procedures
as follows:Self > Check > Boost > Uniform > Amplitude Output >
Shutdown
Click “Timing” key in boost process, the instrument will begin timing
process, or you can wait until the voltage is increased to the set one,
then the instrument will count time automaticly. Then the “Timing” key
will be turned into “Stop” key as shown in Figure 4.
Figure 4
In case the output voltage cannot meet the requirement, click “Up”(slight
increase) or “Down” (slight decrease) keys to adjust the voltage.
Figure 5
a. Timing shut-down: The instrument will shut down at specified set time.
Caution:
• Additionally there are two abnormal shut-down: overvoltage and
overcurrent protective shut-down . the instrument will automatically cut
off the output, then execute the historical data storage. In case of shut-
down, the prompt interface will appear as shown in Figure 7.
7. Print
Click “Print” key as shown in Figure 6, the user can print the data as test
report. On historical data checking status, click “Print” key, the user can
print the historical data.
Figure 7