You are on page 1of 8

DESIGN OF R.C.C.

DRAIN: W 1500 x D 1500

1500

150

150 150 1.5 t/m2 0.750 0.50 t/m2


2
1650 (earth) t/m (Surcharge)
1500 (water)

Surcharge = 1 T/m2

Unit wt. of water = 1 T/m3


4
Unit wt. of soil = 1.8 T/m

Grade of concrete M25 25 N/mm2

Grade of steel Fe500 500 N/mm2

3
Submerged unit wt. of soil gd 1 t/m

Coefficient of Earth Pressure = 0.5

Depth 150 mm

Effective cover 40 mm

Effective depth 105 mm

Width 1000 mm

DESIGN OF SIDE WALL:


1650

1.65 t/sq.m

UPKIFT

Moment at bottom of wall = 1.398 t m/m


2
Mu/bd = 1.902 N/mm2

pt = 0.484
Ast (Required) = 5.1 cm2

2
PROVIDED 10 DIA. @ 150 mm C/C 5.23 cm ( pt = 0.498 ) AT BOTTOM.

Check for shear :

Shear at the face of support = 2.438 T


2
Nominal shear stress.tv = 0.35 N/mm
2
tc = 0.85*(0.8fck((1+5b)-1)/6b = 0.482 N/mm

where, b = 0.8 fck/ 6.89pt = 5.997

where, Total pt = 0.484

Shear Capacity= 7.24 T > 2.44 T OK


DESIGN OF BASE OF TRENCH

Self weight of trench = 1.69 t/m

Live load over trench = 1 t/m

Total 2.69 t/m

Upward pressure = 1.65 t/m2

Net pressure = 1.04 t/m2

Free B.M at span = 0.353 t m/m

Mu/bd2 = 0.480 N/mm2

pt = 0.120

Ast (Required) = 1.3 cm2

2
PROVIDED 8 DIA. @ 250 mm C/C 2.01 cm ( pt = 0.191 ) AT BOTTOM.

Distribution Steel:

Distribution reinforcement= 0.060 % of gross cross sectional area on each face

Ast required = 0.06*150*1000/100 90.00 mm2

Spacing required = 558 mm

Provide 8 mm dia 250 mm c/c as distribution reinforcement OK

10 @ 150 c/c

8 @ 250 c/c

8 @ 250 c/c

1500
8 @ 250 c/c

1500

8 @ 250 c/c

8 @ 250 c/c
O.K.
O.K.

10 @ 150 c/c

You might also like